Home › ENGINE › 3MZ-FE ENGINE CONTROL SYSTEM › SFI SYSTEM

SFI SYSTEM > EVAP System

for Preparation Click here


DESCRIPTION

While the engine is running, if predetermined conditions (closed loop, etc.) are met, the purge VSV is opened by the ECM (included in the hybrid vehicle control ECU) and stored fuel vapors in the canister are purged to the intake manifold. The ECM will change the duty cycle ratio of the Purge VSV to control purge flow volume.
Purge flow volume is also determined by the intake manifold pressure. Atmospheric pressure is allowed to enter the canister through the vent valve to ensure that purge flow is maintained when negative pressure (vacuum) is applied to the canister.
The ECM monitors the condition of both the key-off monitor and purge flow monitor to ensure proper operation of the EVAP system.

A172437E02


A153026E04


Components
Operation
Canister
Contains activated charcoal to absorb fuel vapors that are created in fuel tank.
Cut-off valve
Located in the fuel tank. Valve closes by its own weight when vehicle is overturned to prevent fuel from spilling out.
Purge VSV
Opens or closes line between canister and intake manifold. ECM (included in the hybrid vehicle control ECU) opens and closes purge VSV to control EVAP purge flow. ECM opens purge valve to purge the fuel vapors that were absorbed by canister to intake manifold. ECM controls EVAP volume purged to intake manifold by duty cycle (current-carrying time) to purge valve.
(ON: Open, OFF: Closed)
Roll-over valve
Located in fuel tank. Valve floats and closes when fuel tank is filled to 100%. Also, valve closes by its own weight when vehicle is overturned to prevent fuel from spilling out.
Soak timer
Built into ECM (included in the hybrid vehicle control ECU). To ensure that EVAP monitor values will be accurate, soak timer counts 5 hours (-15 minutes) from when power switch is turned off. This will allow fuel to cool down, which will stabilize Fuel Tank Pressure (FTP).
When approximately 5 hours have passed, ECM turns ON (refer to fig. 3).
Fuel vapor-containment valve
Opens and closes line between fuel tank and canister. When vehicle is stopped, this valve stays closed to keep fuel vapors in the tank and prevent them from being absorbed by canister. During refueling, valve opens to allow fuel vapors from tank to be absorbed by canister. When the vehicle is being driven, the valve maintains a slight positive pressure in the fuel tank.
Fuel tank pressure sensor
Converts pressure in fuel tank into voltage reading for use by ECM (included in the hybrid vehicle control ECU). ECU supplies 5 V to sensor, and uses voltage reading that is output as feedback to allow monitoring of fuel tank pressure (refer to fig. 3).
Canister pump module
The following 5 items labeled (a) to (e) are canister pump module components. Canister pump module cannot be disassembled.
(a) Vent valve
Can either close vent for canister, or open vent to atmosphere. When ECM (included in hybrid vehicle control ECU) turns valve on, canister vent is closed. Alternately, when ECM turns valve off, canister vent is opened to atmosphere. To check for leaks in EVAP system, purge VSV is left closed, vent valve is turned on (canister vent is closed), and vacuum pump is operated to create a vacuum (negative pressure) is system (refer to fig. 1).
(b) Canister pressure sensor
ECM (included in hybrid vehicle control ECU) applies 5 V to pressure sensor, allowing it to create voltage reading that is used by ECM to detect pressure in canister (refer to fig. 2).
(c) Check valve
Composed of nylon ball and spring. Valve blocks off atmosphere from outlet of vacuum pump.
(d) Leak detection pump
Used to create negative pressure in EVAP system to allow checking for leaks.
(e) Reference orifice
The diameter of reference orifice is 0.02 inches. Vacuum (negative pressure) is created, and pressure is measured with purge VSV closed (off) and vent valve off (in vent position). This reference pressure is used to set a baseline (criterion pressure) against which a small leak can be judged.

A109191E02


A115543E06


A141702E03


A109185E01

  1. Key-off monitor
    This monitoring system checks for canister pump module malfunctions and leaks from the EVAP and closed tank systems. Be sure to leave the vehicle for at least 5 hours to sufficiently cool the fuel and stabilize fuel tank pressure. This makes EVAP system monitoring more accurate.

    HINT:
    If the engine coolant temperature is 35°C or more, 5 hours after the power switch has been turned off, the ECM (included in the hybrid vehicle control ECU) will begin performing a monitor check after another 2 hours. If the engine coolant temperature is still 35°C or more, 7 hours after the power switch has been turned off, the ECM will begin performing a monitor check after another 2.5 hours.

    There are two methods for monitoring the EVAP system.
    1. If the fuel tank pressure is higher or lower than the atmospheric pressure, the system determines that there are no leaks in the closed tank system and the system will check for leaks from the piping and canister between the purge VSV and canister pump module. (Method A)
    2. If the fuel tank pressure is almost the same as the atmospheric pressure, vacuum will be allowed to enter the fuel tank and the system will check for leaks from the fuel tank after checking for leaks from the canister. (Method B)

A109186E03


Sequence
Operation
Description
Duration
-
ECM (Included in hybrid vehicle control ECU) activation
Activated by soak timer, 5 hours (7 or 9.5 hours) after power switch turned off.
-
A
Atmospheric pressure measurement
Vent valve turned OFF (vent) and EVAP system pressure is measured by ECM (included in the hybrid vehicle control ECU) in order to register atmospheric pressure.
If pressure in EVAP system is not between 70 kPa and 110 kPa (525 mmHg and 825 mmHg), ECM (included in hybrid vehicle control ECU) cancels EVAP system monitor.
10 seconds
B
First 0.02 inch leak pressure measurement
In order to determine 0.02 inch leak pressure standard, vacuum pump creates negative pressure (vacuum) through 0.02 inch orifice and then ECM (included in the hybrid vehicle control ECU) checks if vacuum pump and vent valve operate normally.
60 seconds
C
EVAP system pressure measurement
Vent valve is turned ON (closed) to shut EVAP system.
Negative pressure (vacuum) is created in EVAP system, and EVAP system pressure is then measured.
Write down measured values as they will be used in leak check.
If EVAP pressure does not stabilize within 15 minutes, ECM (included in hybrid vehicle control ECU) cancels EVAP system monitor.
15 minutes
D
Purge VSV monitor
Purge VSV opens and then EVAP system pressure is measured by ECM (included in hybrid vehicle control ECU).
Large increase indicates normal.
10 seconds
E
Second 0.02 inch leak pressure measurement
After second 0.02 inch leak pressure measurement, leak check is performed by comparing first and second 0.02 inch leak pressure standards.
If stabilized system pressure is higher than second 0.02 inch leak pressure standard, ECM (included in the hybrid vehicle control ECU) determines that EVAP system has a leak.
60 seconds
F
Resetting
Fuel tank pressure is compared with atmospheric pressure. If tank pressure is higher than PH or lower than PL, ECM (Included in hybrid vehicle control ECU) determines that EVAP system is normal and runs sequence I in method B. If tank pressure is around atmospheric pressure, ECM performs sequence G in method A.
5 seconds
G
Fuel tank pressure measurement
Vent valve is turned ON (closed). Fuel vapor-containment valve opens to allow negative pressure to enter the fuel tank and fuel tank pressure is measured.
Write down measured values because they will be used in leak check.
If fuel tank pressure does not stabilize within 15 minutes, ECM (included in the hybrid vehicle control ECU) stops monitoring.
15 seconds*
H
Third 0.02 inch leak pressure measurement
After 3rd 0.02 inch leak pressure measurement, leak check of fuel tank is performed. If recorded fuel tank pressure is higher than 3rd 0.02 inch leak pressure, ECM (included in the hybrid vehicle control ECU) determines that EVAP system has a leakage.
60 seconds
I
Fuel vapor-containment valve close stuck check
Fuel vapor-containment valve is opened for a certain period of time to check whether the valve is stuck closed.
0.1 second
J
Final check
Atmospheric pressure is measured and then monitoring result is recorded by ECM (included in the hybrid vehicle control ECU).
-

HINT:
*: If there is only a small amount of fuel in the fuel tank, stabilizing the EVAP pressure takes longer than usual.


A109158E02

  1. Purge flow monitor
    If EVAP system pressure change is less than 7.5 mmHg (1 kPa) when the engine is running and the purge VSV is turned ON (closed), the ECM (included in the hybrid vehicle control ECU) determines that the purge flow is insufficient.

    A153027E04


RELATED DTCS


DTC No.
Monitoring Item
P043E
0.02 inch orifice low flow
P043F
0.02 inch orifice high flow
P0441
  1. Purge VSV stuck close
  2. Purge VSV stuck open
  3. Insufficient purge flow
P1420
0.02 inch leak from canister
P1421
Gross leak from canister
P1422
0.02 inch leak from fuel tank
P1423
Gross leak from fuel tank
P2401
Vacuum pump stuck OFF
P2402
Vacuum pump stuck ON
P2419
Vent valve stuck ON (close)
P2420
Vent valve stuck OFF (vent)
P2450
Fuel vapor-containment valve stuck open
P2451
Fuel vapor-containment valve stuck close

MONITOR RESULT

Refer to CHECKING MONITOR STATUS (Click here).

CONFIRMATION DRIVING PATTERN


KEY-OFF MONITOR DRIVE PATTERN
  1. Connect the Techstream to the DLC3.

  2. Confirm the following conditions are satisfied:

    1. The fuel level is less than 90%.
    2. The altitude is less than 8000 ft. (2400 m).
    3. The vehicle is stopped (the vehicle speed is less than 2 mph).
    4. The engine coolant temperature is 4.4 to 35°C (40 to 95°F)
    5. The intake air temperature is 4.4 to 35°C (40 to 95°F)

  3. Perform the drive pattern:

    1. Allow the engine to idle for 5 minutes or more.

    2. Turn the power switch off and wait 6 hours.

  4. Check the monitor status with the Techstream.


PURGE FLOW MONITOR DRIVE PATTERN (P0441)
  1. Connect the Techstream to the DLC3.

  2. Confirm that the following conditions are satisfied:

    1. The engine coolant temperature is more than 4.4°C (40°F).
    2. The intake air temperature is more than 4.4°C (40°F).

  3. Perform the drive pattern:

    1. Remove and reinstall the fuel cap to release the fuel tank pressure.

    2. Warm the engine until the engine coolant temperature reaches 75°C (167°F) or more.

    3. Run the engine at 3000 rpm once.

    4. Allow the engine to idle and turn on the air conditioning (A/C) for 1 minute.

  4. Check the monitor status with the Techstream.


WIRING DIAGRAM


A179772E01


INSPECTION PROCEDURE

1.CONFIRM DTC
  1. Turn the power switch off and wait 10 seconds.

  1. Turn the power switch on (IG).

  1. Turn the power switch off and wait 10 seconds.

  1. Connect the Techstream to the DLC3.

  1. Turn the power switch on (IG) and turn the Techstream switch on.

  1. Enter the following menus: Powertrain / Engine and ECT / Trouble Codes.

  1. Confirm the DTCs and freeze frame data.

    EVAP Related DTCs 
    DTC No.
    Monitoring Item
    P043E
    0.02 inch orifice low flow
    P043F
    0.02 inch orifice high flow
    P0441
    1. Purge VSV stuck close
    2. Purge VSV stuck open
    3. Insufficient purge flow
    P1420
    0.02 inch leak from canister
    P1421
    Gross leak from canister
    P1422
    0.02 inch leak from fuel tank
    P1423
    Gross leak from fuel tank
    P2401
    Vacuum pump stuck OFF
    P2402
    Vacuum pump stuck ON
    P2419
    Vent valve stuck ON (close)
    P2420
    Vent valve stuck OFF (vent)
    P2450
    Fuel vapor-containment valve stuck open
    P2451
    Fuel vapor-containment valve stuck close

    DTC and Malfunction Cross-Reference 
    Malfunction
    Output DTC
    0.02 inch orifice low flow
    P043E, P043F, P2401, P2402, P2419
    0.02 inch orifice high flow
    P043E, P043F, P2401, P2402, P2419
    Vacuum pump stuck OFF
    P043E, P043F, P2401, P2402, P2419
    Vacuum pump stuck ON
    P043E, P043F, P2401, P2402, P2419
    Vent valve stuck ON (closed)
    P043E, P043F, P2401, P2402, P2419
    Vent valve stuck OFF (vent)
    P2420
    Insufficient purge flow
    P0441
    Purge VSV stuck open
    P0441, P1421
    Purge VSV stuck close
    P0441
    0.02 inch leak from canister
    P1420
    Gross leak from canister
    P0441, P1421
    0.02 inch leak from fuel tank
    P1422
    Gross leak from fuel tank
    P1423
    Fuel vapor-containment valve stuck open
    P1423, P2450
    Fuel vapor-containment valve stuck close
    P2451


NEXT


2.PERFORM EVAP SYSTEM CHECK (AUTOMATIC MODE)

NOTICE:
  1. In the Evaporative System Check (Automatic Mode), a series of 6 EVAP SYSTEM CHECK steps are performed automatically. A maximum of 15 minutes is required.
  2. Do not perform the EVAP SYSTEM CHECK when the fuel tank is more than 90% full because the cut-off valve may be closed and the leak check of the fuel tank is impossible.
  3. Do not run the engine.
  4. When the temperature of the fuel is 35°C (95°F) or more, a large amount of vapor forms and any check results become inaccurate. When performing an Evaporative System Check, keep the temperature below 35°C (95°F).

  1. Clear the DTCs with the Techstream.

  1. Remove the fuel tank cap and reinstall the fuel cap.

  1. Enter the following menus: Powertrain / Engine and ECT / Utility / Evaporative System Check / Automatic Mode.

  1. After the Evaporative System Check is completed, check for pending DTCs.

    Result:

    DTC
    Conclusion
    Proceed to
    A pending DTC is set
    A malfunction occurs and troubleshooting can be performed
    A
    A pending DTC is not set
    No malfunctions occur and it is difficult to perform troubleshooting
    B
    A pending DTC is not set and any of the current DTCs (P1422, P1423, or P2450) is set
    DTCs can be set because the fuel cap is not tightened firmly
    C



B
Go to step 34

C
END
A


3.IDENTIFY TROUBLE AREAS USING DTC
  1. Refer to the table below to determine the next procedure according to the output DTCs.

    Result:

    Malfunction
    Output DTC
    Proceed to
    0.02 inch orifice low flow
    P043E, P043F, P2401, P2402 and P2419
    B
    0.02 inch orifice high flow
    P043E, P043F, P2401, P2402 and P2419
    B
    Vacuum pump OFF stuck
    P043E, P043F, P2401, P2402 and P2419
    B
    Vacuum pump ON stuck
    P043E, P043F, P2401, P2402 and P2419
    B
    Vent valve ON (closed) stuck
    P043E, P043F, P2401, P2402 and P2419
    B
    Vent valve OFF (vent) stuck
    P2420
    C
    Insufficient purge flow
    P0441
    A
    Purge VSV open stuck
    P0441 and P1421
    A
    Purge VSV close stuck
    P0441
    A
    0.02 inch leak from canister
    P1420
    D
    Gross leak from canister
    P0441 and P1421
    A
    0.02 inch leak from fuel tank
    P1422
    A
    Gross leak from fuel tank
    P1423
    A
    Fuel vapor-containment valve stuck open
    P1423 and P2450
    A
    Fuel vapor-containment valve stuck close
    P2451
    A



B
Go to step 11

C
Go to step 15

D
Go to step 6
A


4.IDENTIFY TROUBLE AREAS USING DTC
  1. Refer to the table below to determine the next procedure according to the output DTCs.

    Result:

    Malfunction
    Output DTC
    Proceed to
    Insufficient purge flow
    P0441
    A
    Purge VSV stuck open
    P0441, P1421
    B
    Purge VSV stuck close
    P0441
    A
    Gross leak from canister
    P0441, P1421
    B
    0.02 inch leak from fuel tank
    P1422
    C
    Gross leak from fuel tank
    P1423
    C
    Fuel vapor-containment valve stuck open
    P1423, P2450
    C
    Fuel vapor-containment valve stuck close
    P2451
    D



B
Go to step 15

C
Go to step 21

D
Go to step 23
A


5.CHECK VACUUM HOSE (PURGE VSV - THROTTLE BODY)


    A096856E04
  1. Disconnect the hose (to the intake air connector) from the purge VSV.

  1. Start the engine.

  1. Use your finger and confirm that the purge VSV has suction.

    Result:

    Result
    Proceed to
    There is suction.
    Conclusion: EVAP hose between purge VSV and throttle body is normal.
    OK
    There is no suction.
    Conclusion: Problem in throttle body or hose between purge VSV and throttle body
    NG



NG
Go to step 33
OK


6.PERFORM ACTIVE TEST USING TECHSTREAM (PURGE VSV)


    A086478E05
  1. Disconnect the hose (to canister) from the purge VSV.

  1. Start the engine.

  1. Enter the following menus on the Techstream: Powertrain / Engine and ECT / Active Test / Active the VSV for EVAP Control.

  1. Turn the purge VSV OFF.

  1. Use your finger and confirm that the purge VSV has no suction.

  1. Turn the Purge VSV ON.

  1. Use your finger and confirm that the purge VSV has suction.

    OK:
    Purge VSV functions normally

    Result:
    Result
    Proceed to
    Normal
    B
    Malfunction
    A



B
Go to step 19
A


7.CHECK PURGE VSV


    A110919E02
  1. Remove the purge VSV.

  1. Apply compressed air to the purge VSV, and confirm that no air flows from A to B as shown in the illustration.

  1. Apply battery voltage to the purge VSV.

  1. While applying compressed air, confirm that air flows from A to B as shown in the illustration.

    Result:

    Result
    Proceed to
    Air flows from A to B.
    Conclusion: purge VSV is normal.
    OK
    No air flows from A to B.
    Conclusion: purge VSV is malfunctioning.
    NG



NG
Go to step 27
OK


8.CHECK HARNESS AND CONNECTOR (PURGE VSV - EFI NO. 3 FUSE)


    A178669E02
  1. Disconnect the purge VSV connector.

  1. Turn the power switch on (IG).

  1. Measure the voltage between terminal 1 of the B29 connector and body ground.

    Result:

    Result
    Proceed to
    11 to 14 V
    Conclusion: No problem exists in power source.
    OK
    Except above
    Conclusion: Problem in wire or connector between purge VSV and ECM (included in the hybrid vehicle control ECU).
    NG



NG
Go to step 32
OK


9.CHECK HARNESS AND CONNECTOR (PURGE VSV - HYBRID VEHICLE CONTROL ECU)


    A178670E04
  1. Disconnect the hybrid vehicle control ECU connector and the purge VSV connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    B1-17 (PRG) - B29-2
    Always
    10 Ω or less
    B1-17 (PRG) or B29-2 - Body ground
    Always
    10 kΩ or more



NG
Go to step 32
OK


10.REPLACE HYBRID VEHICLE CONTROL ECU
  1. Replace the hybrid vehicle control ECU (Click here).


NEXT

PERFORM EVAP SYSTEM CHECK AGAIN (AUTOMATIC MODE) 

11.CHECK CANISTER PUMP MODULE (VACUUM PUMP POWER SOURCE CIRCUIT)


    A178671E04
  1. Turn the power switch off.

  1. Remove the canister lower cover.

  1. Disconnect the canister pump module connector.

  1. Connect the Techstream to the DLC3.

  1. Turn the power switch on (IG).

  1. Enter the following menus: Powertrain / Engine and ECT / Active Test / Activate the Vacuum Pump.

  1. Turn the vacuum pump on using the Techstream.

  1. Measure the voltage between terminals 1 and 6 of the O42 connector.

    Standard voltage:
    10 to 14 V

    Result:
    Voltage
    Proceed to
    Out of standard range
    A
    within standard range
    B



B
Go to step 15
A


12.CHECK HARNESS AND CONNECTOR (VACUUM PUMP - BODY GROUND)


    A178672E02
  1. Turn the power switch off.

  1. Measure the resistance between terminal O42-6 and body ground.

    Standard resistance:
    Below 10 Ω



NG
Go to step 32
OK


13.CHECK HARNESS AND CONNECTOR (VACUUM PUMP - HYBRID VEHICLE CONTROL ECU)


    A184183E01
  1. Disconnect the hybrid vehicle control ECU connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    D36-6 (MPMP) - O42-1
    Always
    10 Ω or less
    D36-6 (MPMP) or O42-1 - Body ground
    Always
    10 kΩ or more

  1. Connect the hybrid vehicle control ECU connector.



NG
Go to step 32
OK


14.REPLACE HYBRID VEHICLE CONTROL ECU
  1. Replace the hybrid vehicle control ECU (Click here).


NEXT

PERFORM EVAP SYSTEM CHECK AGAIN (AUTOMATIC MODE) 

15.CHECK CANISTER PUMP MODULE (VENT VALVE POWER SOURCE CIRCUIT)


    A178671E04
  1. Turn the power switch off.

  1. Remove the canister lower cover.

  1. Disconnect the canister pump module connector.

  1. Connect the Techstream to the DLC3.

  1. Turn the power switch on (IG).

  1. Enter the following menus: Powertrain / Engine and ECT / Active Test / Activate the Vacuum Pump.

  1. Turn the vacuum pump on using the Techstream.

  1. Measure the voltage between terminals 8 and 9 of the O42 connector and body ground.

    Standard voltage:
    10 to 14 V

    Result:
    Voltage
    Proceed to
    Out of standard range
    A
    within standard range
    B



B
Go to step 28
A


16.CHECK HARNESS AND CONNECTOR (VENT VALVE - BODY GROUND)


    A178672E02
  1. Turn the power switch off.

  1. Measure the resistance between terminal O42-9 and body ground.

    Standard resistance:
    Below 10 Ω



NG
Go to step 32
OK


17.CHECK HARNESS AND CONNECTOR (VENT VALVE - HYBRID VEHICLE CONTROL ECU)


    A184183E02
  1. Disconnect the hybrid vehicle control ECU connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    D36-16 (VPMP) - O42-8
    Always
    10 Ω or less
    D36-16 (VPMP) or O42-8 - Body ground
    Always
    10 kΩ or more

  1. Connect the hybrid vehicle control ECU connector.



NG
Go to step 32
OK


18.REPLACE HYBRID VEHICLE CONTROL ECU
  1. Replace the hybrid vehicle control ECU (Click here).


NEXT


19.CHECK HOSES (PURGE VSV - CANISTER)
  1. Remove the canister cover.



    A156067E01
  1. Connect the pressure gauge (SST) to the canister pump module with the adapter.

  1. Pressurize the EVAP system to between 3.2 and 3.7 kPa (24 and 28 mmHg).

    NOTICE:
    More than 4.7 kPa (35 mmHg) of pressure will damage the EVAP system. Pay attention to the pressure.

  1. Apply soapy water to the piping and connections of the EVAP system. Look for the area where bubbles appear.

    HINT:
    1. If the system has leaks, a whistling sound will be heard.
    2. Disconnect the hose between the canister and fuel tank from the canister. Close the canister on the area where the hose was connected and perform an inspection. The fuel tank can be eliminated from the suspected areas for leak checks.


NEXT


20.REPLACE MALFUNCTIONING PART

NEXT

PERFORM EVAP SYSTEM CHECK AGAIN (AUTOMATIC MODE) 

21.CHECK FUEL TANK CAP ASSEMBLY
  1. Check if the fuel cap is tightened until a few "click" sounds are heard.

  1. If you have the EVAP tester, check the fuel cap using the fuel cap adaptor.

    1. Install the fuel cap to the fuel cap adaptor, and connect the hose from the EVAP tester's pump.

    2. Pressurize the fuel cap adaptor to between 3.2 and 3.7 kPa (24 and 28 mmHg) or for 45 seconds.

    3. Stop the pump and seal the fuel cap adaptor.

    4. Wait 2 minutes.

    5. Confirm that the pressure is higher than 2.0 kPa (15 mmHg).

      OK:
      Higher than 2.0 kPa (15 mmHg)



NG
Go to step 31
OK


22.CHECK HOSES (FUEL VAPOR-CONTAINMENT VALVE - FUEL TANK)
  1. Remove the canister cover.



    A156067E01
  1. Connect the pressure gauge (SST) to the canister pump module with the adapter.

  1. Connect the Techstream to the DLC3.

  1. Turn the power switch on (IG).

  1. Enter the following menus: Powertrain / Engine and ECT / Active Test / Activate the Fuel Vapor-Containment Valve.

  1. Turn the fuel vapor-containment valve ON using the Techstream.

  1. Pressurize the EVAP system to between 3.2 and 3.7 kPa (24 and 28 mmHg).

    NOTICE:
    More than 4.7 kPa (35 mmHg) of pressure will damage the EVAP system. Pay attention to the pressure.

  1. Apply soapy water to the piping and connections of the EVAP system. Look for the area where bubbles appear.

    HINT:
    1. If the system has leaks, a whistling sound will be heard.
    2. Disconnect the hose between the canister and fuel tank from the canister. Close the canister on the area where the hose was connected and perform an inspection. The fuel tank can be eliminated from the suspected areas for leak checks.


NEXT


23.CHECK FUEL VAPOR-CONTAINMENT VALVE ASSEMBLY (POWER SOURCE CIRCUIT)


    A109172E03
  1. Turn the power switch off.

  1. Disconnect the Ok1 connector.

  1. Connect the Techstream to the DLC3.

  1. Turn the power switch on (IG).

  1. Enter the following menus: Powertrain / Engine and ECT / Active Test / Activate the Fuel Vapor-Containment Valve.

  1. Turn the fuel vapor-containment valve ON using the Techstream.

  1. Measure the voltage between terminals 3 and 7 of the Ok1 connector.

    Standard voltage:
    10 to 14 V

    Result:
    Voltage
    Proceed to
    Out of standard range
    A
    within standard range
    B



B
Go to step 29
A


24.CHECK HARNESS AND CONNECTOR (FUEL VAPOR-CONTAINMENT VALVE - IGCT FUSE)


    A178674E02
  1. Turn the power switch on (IG).

  1. Measure the voltage between terminal Ok1-3 and body ground.

    Standard voltage:
    10 to 14 V



NG
Go to step 32
OK


25.CHECK HARNESS AND CONNECTOR (FUEL VAPOR-CONTAINMENT VALVE - HYBRID VEHICLE CONTROL ECU)


    A178673E10
  1. Disconnect the hybrid vehicle control ECU connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    D36-12 (CCV2) - Ok1-3
    Always
    10 Ω or less
    D36-12 (CCV2) or Ok1-3 - Body ground
    Always
    10 kΩ or more

  1. Connect the hybrid vehicle control ECU connector.



NG
Go to step 32
OK


26.REPLACE HYBRID VEHICLE CONTROL ECU
  1. Replace the hybrid vehicle control ECU (Click here).


NEXT

PERFORM EVAP SYSTEM CHECK AGAIN (AUTOMATIC MODE) 

27.REPLACE PURGE VSV
  1. Replace the purge VSV (Click here).


NEXT

PERFORM EVAP SYSTEM CHECK AGAIN (AUTOMATIC MODE) 

28.REPLACE CANISTER ASSEMBLY
  1. Replace the canister assembly (Click here).


NEXT

PERFORM EVAP SYSTEM CHECK AGAIN (AUTOMATIC MODE) 

29.CHECK HARNESS AND CONNECTOR (TANK WIRE HARNESS)
  1. Remove the fuel tank assembly. (Click here)



    A109176E03
  1. Disconnect the fuel vapor-containment valve connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    Ok1-3 - k3-1
    Always
    Below 1 Ω
    Ok1-7 - k3-2
    Always
    Below 1 Ω

  1. Reinstall the fuel tank assembly. (Click here)



NG
Go to step 32
OK


30.REPLACE FUEL VAPOR-CONTAINMENT VALVE
  1. Replace the fuel vapor-containment valve (Click here).


NEXT

PERFORM EVAP SYSTEM CHECK AGAIN (AUTOMATIC MODE) 

31.REPLACE FUEL TANK CAP ASSEMBLY

NEXT

PERFORM EVAP SYSTEM CHECK AGAIN (AUTOMATIC MODE) 

32.REPAIR OR REPLACE HARNESS OR CONNECTOR

NEXT

PERFORM EVAP SYSTEM CHECK AGAIN (AUTOMATIC MODE) 

33.REPAIR OR REPLACE VACUUM HOSE (PURGE VSV - THROTTLE BODY)

NEXT

PERFORM EVAP SYSTEM CHECK AGAIN (AUTOMATIC MODE) 

34.PERFORM EVAP SYSTEM CHECK (MANUAL MODE)

HINT:
In the manual operation check, the EVAP system can be checked in several steps. Valve operation and pressure in each step can also be checked.

  1. Clear the DTCs (Click here).

  1. Remove the fuel tank cap and reinstall the fuel tank cap.



  1. Select the following menu items: Powertrain / Engine and ECT / Utility / Evaporative System Check / Manual Mode.

    NOTICE:
    1. In the Evaporative System Check (Manual Mode), the series of 9 EVAP SYSTEM CHECK steps is performed automatically. It takes a maximum of approximately 18 minutes.
    2. Do not perform the Evaporative System Check when the fuel tank is more than 90% full because the cut-off valve may be closed, making the leak check of the fuel tank impossible.
    3. Do not run the engine in this step.
    4. When the temperature of the fuel is 35°C (95°F) or more, a large amount of vapor forms and any check results become inaccurate. When performing the Evaporative System Check, keep the temperature below 35°C (95°F).


    Tester Display 
    Display
    Details
    Atmosphere Press Check
    The number of steps and step names are displayed
    Purge VSV
    Purge VSV condition is displayed: ON (Open)/ OFF (Closed)
    VENT VALVE
    Vent valve condition is displayed: ON (Closed)/ OFF (Vent)
    VACUUM PUMP
    Vacuum pump condition is displayed: ON/ OFF
    FVCV
    Fuel vapor-containment valve condition is displayed: ON (Open)/ OFF (Closed)
    TANK PRESS
    Fuel tank pressure (Gauge pressure)
    VAPOR PRESS
    EVAP pressure (Gauge pressure)
    VAPOR PRESS
    EVAP pressure (Absolute pressure)
    Time (Step)
    Elapsed time for each step
    Time (VSV)
    Accumulated purge VSV open time
    Time (PUMP)
    Accumulated vacuum pump operating time

    Manual Operation Step 
    Step
    Operations
    1. Arm Press Check 1
    Atmospheric pressure measurement
    2. Ref Press Check 1
    First 0.02 inch leak pressure measurement
    3. Leak Check
    EVAP system pressure measurement
    4. Purge VSV Check
    Purge VSV monitor
    5. Ref Press Check 2
    Second 0.02 inch leak pressure measurement
    6. Resetting
    Resetting
    7. Tank Leak Check
    Fuel tank pressure measurement
    8. Ref Press Check 3
    Third 0.02 inch leak pressure measurement

    A110928E05


NEXT


35.PERFORM EVAP SYSTEM CHECK (MANUAL MODE STEP 1)
  1. Select step 1 and wait 10 seconds.


NEXT


36.PERFORM EVAP SYSTEM CHECK (MANUAL MODE STEP 2)
  1. Perform step 2.



  1. Check the EVAP pressure 2 seconds after the vacuum pump is activated*.
    *: The vacuum pump begins to operate at the start of step 2.


    A109177E05



  1. Check the EVAP pressure again when it has stabilized. This pressure is the first reference pressure standard.


    A109178E04


    Result:

    Test Results
    Suspected Trouble Areas
    Proceed to
    EVAP pressure in step (b) is between -4.85 kPa and -1.06 kPa (-36.38 mmHg and -7.95 mmHg)
    Not yet determined
    A
    EVAP pressure in step (b) is -1.06 kPa (-7.95 mmHg) or more
    1. 0.02 inch orifice high-flow
    2. Vacuum pump stuck OFF
    B
    EVAP pressure in step (b) is below -4.85 kPa (-36.38 mmHg)
    0.02 inch orifice clogged
    C



B
Go to step 50

C
Go to step 65
A


37.PERFORM EVAP SYSTEM CHECK (MANUAL MODE STEP 3)
  1. Perform step 3.



  1. Check the EVAP pressure change in step 3.


    A109179E05


    Result:

    Test Results
    Suspected Trouble Areas
    Proceed to
    EVAP pressure change in step (b) is 0.3 kPa (2.25 mmHg) or more
    Not yet determined
    A
    EVAP pressure in step (b) is below 0.3 kPa (2.25 mmHg)
    Vent valve stuck OFF
    B



  1. Check the fuel tank pressure change in step 3.


    A109180E06


    Result:

    Test Results
    Suspected Trouble Areas
    Proceed to
    Fuel tank pressure in step (b) is below 0.5 kPa (3.75 mmHg)
    Not yet determined
    A
    Fuel tank pressure change in step (b) is 0.5 kPa (3.75 mmHg) or more
    Fuel vapor-containment valve stuck ON (open)
    C

  1. Check the EVAP pressure again when it has stabilized. This pressure is the canister leak pressure standard.



  1. Compare the first reference pressure with the canister leak pressure.


    A109181E05


    Result:

    Test Results
    Suspected Trouble Areas
    Proceed to
    Lower than first reference pressure
    Not yet determined
    A
    First reference pressure or higher
    1. Purge VSV stuck open
    2. Leakage from line between purge VSV and canister
    D



B
Go to step 54

C
Go to step 60

D
Go to step 45
A


38.PERFORM EVAP SYSTEM CHECK (MANUAL MODE STEP 4)
  1. Perform step 4.



  1. Check the EVAP pressure change in step 3.


    A109182E06


    Result:

    Test Results
    Suspected Trouble Areas
    Proceed to
    EVAP pressure change in step (b) is 0.3 kPa (2.25 mmHg) or more
    Not yet determined
    A
    EVAP pressure in step (b) is below 0.3 kPa (2.25 mmHg)
    Vent valve stuck OFF
    B



B
Go to step 44
A


39.PERFORM EVAP SYSTEM CHECK (MANUAL MODE STEP 5)
  1. Perform step 5 and wait 60 seconds.

  1. Check the EVAP pressure. This pressure is the second reference pressure standard.


NEXT


40.PERFORM EVAP SYSTEM CHECK (MANUAL MODE STEP 6)
  1. Perform step 6 and wait 5 seconds.


NEXT


41.PERFORM EVAP SYSTEM CHECK (MANUAL MODE STEP 7)
  1. Perform step 7.

  1. Check that the tank pressure and EVAP pressure change.



  1. Check the tank pressure again when it has stabilized. This pressure is the fuel tank leak pressure standard.


    A109183E05


    Result:

    Test Results
    Suspected Trouble Areas
    Proceed to
    Tank pressure change is more than 0.9 kPa (7 mmHg) and EVAP pressure is more than -1.0 kPa (-7 mmHg)
    Not yet determined
    A
    Tank pressure change is less than 0.9 kPa (7 mmHg) and EVAP pressure is less than -1.0 kPa (-7 mmHg)
    Tank close valve stuck OFF (close)
    B



B
Go to step 60
A


42.PERFORM EVAP SYSTEM CHECK (MANUAL MODE STEP 8)
  1. Perform step 8 and wait 60 seconds.

  1. Check the EVAP pressure. This pressure is the third reference pressure standard.



  1. Compare the tank pressure checked in step 41 with the third reference pressure.


    A109184E02


    Result:

    Test Results
    Suspected Trouble Areas
    Proceed to
    Lower than third reference pressure
    Not yet determined
    A
    Third reference pressure or higher
    Leakage from line between tank close valve and fuel tank
    B



B
Go to step 67
A


43.PERFORM CONFIRMATION DRIVING PATTERN
  1. KEY-OFF MONITOR DRIVE PATTERN

    1. Connect the Techstream to the DLC3.

    2. Confirm the following conditions are satisfied:

      1. The fuel level is less than 90%.
      2. The altitude is less than 8000 ft. (2400 m).
      3. The vehicle is stopped (the vehicle speed is less than 2 mph).
      4. The engine coolant temperature is 4.4 to 35°C (40 to 95°F)
      5. The intake air temperature is 4.4 to 35°C (40 to 95°F)

    3. Perform the drive pattern:

      1. Allow the engine to idle for 5 minutes or more.
      2. Turn the power switch off and wait 6 hours.

    4. Check the monitor status with the Techstream.

  1. PURGE FLOW MONITOR DRIVE PATTERN (P0441)

    1. Connect the Techstream to the DLC3.

    2. Confirm that the following conditions are satisfied:

      1. The engine coolant temperature is more than 4.4°C (40°F).
      2. The intake air temperature is more than 4.4°C (40°F).

    3. Perform the drive pattern:

      1. Remove and reinstall the fuel cap to release the fuel tank pressure.
      2. Warm up the engine until the engine coolant temperature reaches 75°C (167°F) or more.
      3. Run the engine at 3000 rpm once.
      4. Allow the engine to idle and turn on the air conditioning (A/C) for 1 minute.

    4. Check the monitor status with the Techstream.


NEXT

PERFORM EVAP SYSTEM CHECK AGAIN (AUTOMATIC MODE) 

44.CHECK VACUUM HOSE (PURGE VSV - THROTTLE BODY)


    A096856E04
  1. Disconnect the hose (to intake air connector) from the purge VSV.

  1. Start the engine.

  1. Use your finger and confirm that the purge VSV has suction.

    Result:

    Result
    Proceed to
    There is suction.
    Conclusion: EVAP hose between purge VSV and throttle body is normal.
    OK
    There is no suction.
    Conclusion: Problem in throttle body or hose between purge VSV and throttle body
    NG



NG
Go to step 69
OK


45.PERFORM ACTIVE TEST USING TECHSTREAM (PURGE VSV)


    A086478E05
  1. Disconnect the hose (to canister) from the purge VSV.

  1. Start the engine.

  1. Enter the following menus on Techstream: Powertrain / Engine and ECT / Active Test / Active the VSV for EVAP Control.

  1. Turn the purge VSV OFF.

  1. Use your finger and confirm that the purge VSV has no suction.

  1. Turn the purge VSV ON.

  1. Use your finger and confirm that the purge VSV has suction.

    OK:
    Purge VSV functions normally

    Result:
    Result
    Proceed to
    Normal
    B
    Malfunction
    A



B
Go to step 58
A


46.CHECK PURGE VSV


    A110919E02
  1. Remove the purge VSV.

  1. Apply compressed air to the purge VSV, and confirm that no air flows from A to B as shown in the illustration.

  1. Apply battery voltage to the purge VSV.

  1. While applying compressed air, confirm that air flows from A to B as shown in the illustration.

    Result:

    Result
    Proceed to
    Air flows from A to B.
    Conclusion: purge VSV is normal.
    OK
    No air flows from A to B.
    Conclusion: purge VSV is malfunctioning.
    NG



NG
Go to step 64
OK


47.CHECK HARNESS AND CONNECTOR (PURGE VSV - EFI NO. 3 FUSE)


    A178669E02
  1. Disconnect the purge VSV connector.

  1. Turn the power switch on (IG).

  1. Measure the voltage between terminal 1 of the B29 connector and body ground.

    Result:

    Result
    Proceed to
    11 to 14 V
    Conclusion: No problem exists in power source.
    OK
    Except above
    Conclusion: Problem in wire or connector between purge VSV and ECM (Included in hybrid vehicle control ECU).
    NG



NG
Go to step 68
OK


48.CHECK HARNESS AND CONNECTOR (PURGE VSV - HYBRID VEHICLE CONTROL ECU)


    A178670E04
  1. Disconnect the hybrid vehicle control ECU connector and the purge VSV connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    B1-17 (PRG) - B29-2
    Always
    10 Ω or less
    B1-17 (PRG) or B29-2 - Body ground
    Always
    10 kΩ or more

  1. Connect the hybrid vehicle control ECU connector.



NG
Go to step 68
OK


49.REPLACE HYBRID VEHICLE CONTROL ECU
  1. Replace the hybrid vehicle control ECU (Click here).


NEXT

PERFORM EVAP SYSTEM CHECK AGAIN (AUTOMATIC MODE) 

50.CHECK CANISTER PUMP MODULE (VACUUM PUMP POWER SOURCE CIRCUIT)


    A178671E04
  1. Turn the power switch off.

  1. Remove the canister lower cover.

  1. Disconnect the canister pump module connector.

  1. Connect the Techstream to the DLC3.

  1. Turn the power switch on (IG).

  1. Enter the following menus: Powertrain / Engine and ECT / Active Test / Activate the Vacuum Pump.

  1. Turn the vacuum pump on using the tester.

  1. Measure the voltage between terminals 1 and 6 of the O42 connector.

    Standard voltage:
    10 to 14 V

    Result:
    Voltage
    Proceed to
    without standard voltage
    A
    within standard voltage
    B



B
Go to step 54
A


51.CHECK HARNESS AND CONNECTOR (VACUUM PUMP - BODY GROUND)


    A178672E02
  1. Turn the power switch off.

  1. Measure the resistance between terminal O42-6 and body ground.

    Standard resistance:
    Below 10 Ω



NG
Go to step 69
OK


52.CHECK HARNESS AND CONNECTOR (VACUUM PUMP - HYBRID VEHICLE CONTROL ECU)


    A184183E01
  1. Disconnect the hybrid vehicle control ECU connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    D36-6 (MPMP) - O42-1
    Always
    10 Ω or less
    D36-6 (MPMP) or O42-1 - Body ground
    Always
    10 kΩ or more

  1. Connect the hybrid vehicle control ECU connector.



NG
Go to step 68
OK


53.REPLACE HYBRID VEHICLE CONTROL ECU
  1. Replace the hybrid vehicle control ECU (Click here).


NEXT

PERFORM EVAP SYSTEM CHECK AGAIN (AUTOMATIC MODE) 

54.CHECK CANISTER PUMP MODULE (VENT VALVE POWER SOURCE CIRCUIT)


    A178671E04
  1. Turn the power switch off.

  1. Remove the canister lower cover.

  1. Disconnect the canister connector.

  1. Connect the Techstream to the DLC3.

  1. Turn the Power switch on (IG).

  1. Enter the following menus: Powertrain / Engine and ECT / Active Test / Activate the Vacuum Pump.

  1. Turn the vacuum pump on using the tester.

  1. Measure the voltage between terminals 8 and 9 of the O42 connector and body ground.

    Standard voltage:
    10 to 14 V

    Result:
    Voltage
    Proceed to
    without standard voltage
    A
    within standard voltage
    B



B
Go to step 65
A


55.CHECK HARNESS AND CONNECTOR (VENT VALVE - BODY GROUND)


    A178672E02
  1. Turn the power switch off.

  1. Measure the resistance between terminal O42-9 and body ground.

    Standard resistance:
    Below 10 Ω



NG
Go to step 68
OK


56.CHECK HARNESS AND CONNECTOR (VENT VALVE - HYBRID VEHICLE CONTROL ECU)


    A184183E02
  1. Disconnect the hybrid vehicle control ECU connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    D36-16 (VPMP) - O42-8
    Always
    10 Ω or less
    D36-16 (VPMP) or O42-8 - Body ground
    Always
    10 kΩ or more

  1. Connect the hybrid vehicle control ECU connector.



NG
Go to step 68
OK


57.REPLACE HYBRID VEHICLE CONTROL ECU
  1. Replace the hybrid vehicle control ECU (Click here).


NEXT


58.CHECK HOSES (PURGE VSV - CANISTER)
  1. Remove the canister cover.



    A156067E01
  1. Connect the pressure gauge (SST) to the canister pump module with the adapter.

  1. Pressurize the EVAP system to between 3.2 and 3.7 kPa (24 to 28 mmHg).

    NOTICE:
    More than 4.7 kPa (35 mmHg) of pressure will damage the EVAP system. Pay attention to the pressure.

  1. Apply soapy water to the piping and connecting parts of the EVAP system. Look for the area where bubbles appear.

    HINT:
    1. If the system has leaks, a whistling sound will be heard.
    2. Disconnect the hose between the canister and fuel tank from the canister. Close the canister on the area where the hose was connected and perform an inspection. The fuel tank can be eliminated from the suspected areas for leak checks.


NEXT


59.REPLACE MALFUNCTIONING PARTS, COMPONENT AND AREA

NEXT

PERFORM EVAP SYSTEM CHECK AGAIN (AUTOMATIC MODE) 

60.CHECK FUEL VAPOR-CONTAINMENT VALVE ASSEMBLY (POWER SOURCE CIRCUIT)


    A109172E03
  1. Turn the power switch off.

  1. Disconnect the Ok1 connector.

  1. Connect the Techstream to the DLC3.

  1. Turn the power switch on (IG).

  1. Enter the following menus: Powertrain / Engine and ECT / Active Test / Activate the Fuel Vapor-Containment Valve.

  1. Turn the fuel vapor-containment valve ON using the tester.

  1. Measure the voltage between terminals 3 and 7 of the Ok1 connector.

    Standard voltage:
    10 to 14 V

    Result:
    Voltage
    Proceed to
    without standard voltage
    A
    within standard voltage
    B



B
Go to step 66
A


61.CHECK HARNESS AND CONNECTOR (FUEL VAPOR-CONTAINMENT VALVE - IGCT FUSE)


    A178674E02
  1. Turn the power switch on (IG).

  1. Measure the voltage between terminal Ok1-3 and body ground.

    Standard voltage:
    10 to 14 V



NG
Go to step 68
OK


62.CHECK HARNESS AND CONNECTOR (FUEL VAPOR-CONTAINMENT VALVE - HYBRID VEHICLE CONTROL ECU)


    A178673E10
  1. Disconnect the hybrid vehicle control ECU connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    D36-12 (CCV2) - Ok1-3
    Always
    10 Ω or less
    D36-12 (CCV2) or Ok1-3 - Body ground
    Always
    10 kΩ or more

  1. Connect the hybrid vehicle control ECU connector.



NG
Go to step 68
OK


63.REPLACE HYBRID VEHICLE CONTROL ECU
  1. Replace the hybrid vehicle control ECU (Click here).


NEXT

PERFORM EVAP SYSTEM CHECK AGAIN (AUTOMATIC MODE) 

64.REPLACE PURGE VSV
  1. Replace the purge VSV (Click here).


NEXT

PERFORM EVAP SYSTEM CHECK AGAIN (AUTOMATIC MODE) 

65.REPLACE CHARCOAL CANISTER ASSEMBLY
  1. Replace the canister assembly (Click here).


NEXT

PERFORM EVAP SYSTEM CHECK AGAIN (AUTOMATIC MODE) 

66.CHECK HARNESS AND CONNECTOR (TANK WIRE HARNESS)
  1. Remove the fuel tank assembly. (Click here)



    A109176E03
  1. Disconnect the fuel vapor-containment valve connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    Ok1-3 - k3-1
    Always
    Below 1 Ω
    Ok1-7 - k3-2
    Always
    Below 1 Ω

  1. Reinstall fuel tank assembly. (Click here)



NG
Go to step 68
OK


67.REPLACE FUEL VAPOR-CONTAINMENT VALVE
  1. Replace the Fuel vapor- containment Valve (Click here).


NEXT

PERFORM EVAP SYSTEM CHECK AGAIN (AUTOMATIC MODE) 

68.REPAIR OR REPLACE HARNESS OR CONNECTOR

NEXT

PERFORM EVAP SYSTEM CHECK AGAIN (AUTOMATIC MODE) 

69.REPAIR OR REPLACE VACUUM HOSE (PURGE VSV - THROTTLE BODY)

NEXT

PERFORM EVAP SYSTEM CHECK AGAIN (AUTOMATIC MODE)