Home › Power Source / Network › 2GR-FE BATTERY / CHARGING › GENERATOR › 2013.12–2016.11
RM3160E _57 Power Source / Network _019670 2GR-FE BATTERY / CHARGING _0105679 GENERATOR A

2GR-FE BATTERY / CHARGING  GENERATOR  REMOVAL  


PROCEDURE

Hide 1. PRECAUTION

NOTICE:

After turning the ignition switch off, waiting time may be required before disconnecting the cable from the negative (-) battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) battery terminal notice before proceeding with work.

Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION


Hide 2.DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL

NOTICE:

When disconnecting the cable, some systems need to be initialized after the cable is reconnected.

Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>INITIALIZATION


Hide 12142 4.REMOVE NO. 2 ENGINE OIL LEVEL DIPSTICK GUIDE

Hide 27020 6.REMOVE GENERATOR ASSEMBLY

a.
A315039

Open the terminal cap.


b.

Remove the nut and disconnect the wire harness from terminal B.


c.

Disconnect the generator assembly connector from the generator assembly.


d.

Disconnect the compressor and magnetic clutch connector.


e.

Disconnect the 3 wire harness clamps.


f.
A315040

Remove the 2 bolts and then disconnect the generator assembly bracket.


g.
A315041

Remove the 2 bolts and generator assembly.


h.
A315042

Disconnect the wire harness clamp and then remove the generator assembly bracket.


i.
A170743

Remove the bolt and wire harness clamp bracket.