1. PRECAUTION
After turning the ignition switch off, waiting time may be required before disconnecting the cable from the negative (-) battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) battery terminal notice before proceeding with work.
Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION
2.DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL
When disconnecting the cable, some systems need to be initialized after the cable is reconnected.
Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>INITIALIZATION
16711
3.REMOVE FAN SHROUD
12142
4.REMOVE NO. 2 ENGINE OIL LEVEL DIPSTICK GUIDE
5.REMOVE V-RIBBED BELT
27020
6.REMOVE GENERATOR ASSEMBLY
Open the terminal cap.
Remove the nut and disconnect the wire harness from terminal B.
Disconnect the generator assembly connector from the generator assembly.
Disconnect the compressor and magnetic clutch connector.
Disconnect the 3 wire harness clamps.
Remove the 2 bolts and then disconnect the generator assembly bracket.
Remove the 2 bolts and generator assembly.
Disconnect the wire harness clamp and then remove the generator assembly bracket.
Remove the bolt and wire harness clamp bracket.