Refer to the description for DTC P0A8111.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM (for 2WD)>P0A8111
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Warning Indicate |
|---|---|---|---|---|---|
| P0A8100 | Hybrid/EV Battery Cooling Fan 1 Control Circuit High | Both of the following conditions are met:
·
The HV battery temperature is high and the hybrid battery cooling fan speed calculated based on the battery cooling blower assembly (No. 0) output frequency (FP0) is not within the target control speed range. ·
The HV battery temperature is high and the battery cooling blower assembly (No. 0) speed is excessively high when a speed below a certain level is requested. (1 trip detection logic) |
·
Battery cooling blower assembly (No. 0) ·
Battery voltage sensor |
Comes on | Master Warning:
Comes on |
| P0A8115 | Hybrid/EV Battery Cooling Fan 1 Circuit Short to Auxiliary Battery or Open | Both of the following conditions are met:
·
The speed calculated based on the battery cooling blower assembly (No. 0) output frequency (FP0) is not within the target control speed range. ·
The battery cooling blower assembly (No. 0) speed is excessively high when a speed below a certain level is requested. (2 trip detection logic) |
·
Battery cooling blower assembly (No. 0) ·
Battery voltage sensor |
Comes on | Master Warning:
Comes on |
| P0A9600 | Hybrid/EV Battery Cooling Fan 2 Control Circuit High | Both of the following conditions are met:
·
The HV battery temperature is high and the hybrid battery cooling fan speed calculated based on the battery cooling blower assembly (No. 1) output frequency (FP1) is not within the target control speed range. ·
The HV battery temperature is high and the battery cooling blower assembly (No. 1) speed is excessively high when a speed below a certain level is requested. (1 trip detection logic) |
·
Battery cooling blower assembly (No. 1) ·
Battery voltage sensor |
Comes on | Master Warning:
Comes on |
| P0A9615 | Hybrid/EV Battery Cooling Fan 2 Circuit Short to Auxiliary Battery or Open | Both of the following conditions are met:
·
The speed calculated based on the battery cooling blower assembly (No. 1) output frequency (FP1) is not within the target control speed range. ·
The battery cooling blower assembly (No. 1) speed is excessively high when a speed below a certain level is requested. (2 trip detection logic) |
·
Battery cooling blower assembly (No. 1) ·
Battery voltage sensor |
Comes on | Master Warning:
Comes on |
| DTC No. | Data List |
|---|---|
| P0A8100 | ·
Hybrid Battery Cooling Fan 1 Drive Request ·
Hybrid Battery Cooling Fan 1 Drive Status ·
Hybrid Battery Cooling Fan 1 Frequency |
| P0A8115 | |
| P0A9600 | ·
Hybrid/EV Battery Cooling Fan 2 Drive Request ·
Hybrid/EV Battery Cooling Fan 2 Drive Status ·
Hybrid/EV Battery Cooling Fan 2 Frequency |
| P0A9615 |
The following items can be helpful when performing repairs:
Hybrid Battery Temperature 1 to 6
BATT Voltage
"Hybrid Battery Cooling Fan 1 Frequency" is detected when the battery cooling blower assembly (No. 0) is operating and its value changes in proportion to the battery cooling blower assembly (No. 0) speed.
"Hybrid/EV Battery Cooling Fan 2 Frequency" is detected when the battery cooling blower assembly (No. 1) is operating and its value changes in proportion to the battery cooling blower assembly (No. 1) speed.
If the battery cooling blower assembly speed is excessively high, this DTC is stored.
After repair has been completed, clear the DTC and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM (for 2WD)>UTILITY
Connect the GTS to the DLC3.
Turn the ignition switch to ON and turn the GTS on.
Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).
Turn the ignition switch off and wait for 2 minutes or more.
Turn the ignition switch to ON and turn the GTS on.
Enter the following menus: Powertrain / Hybrid Control / Active Test / Control the Hybrid Battery Cooling Fan.
Select fan mode 6 and operate the battery cooling blower assembly and wait for 60 seconds or more.
Operation of the battery cooling blower assembly can be confirmed by checking if air is sucked into the air intake port of the intake duct or by operation sounds.
Enter the following menus: Powertrain / Hybrid Control / Utility / All Readiness.
Check the DTC judgment result.
If the judgment result shows NORMAL, the system is normal.
If the judgment result shows ABNORMAL, the system has a malfunction.
If the judgment result shows INCOMPLETE, perform driving pattern again.
Refer to the wiring diagram for DTC P0A8111.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM (for 2WD)>P0A8111
Before the following operations are conducted, take precautions to prevent electric shock by turning the ignition switch off, wearing insulated gloves, and removing the service plug grip from HV battery.
Inspecting the high-voltage system
Disconnecting the low voltage connector of the inverter with converter assembly
Disconnecting the low voltage connector of the HV battery
To prevent electric shock, make sure to remove the service plug grip to cut off the high voltage circuit before servicing the vehicle.
After removing the service plug grip from the HV battery, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
| *a | Without waiting for 10 minutes |
After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM (for 2WD)>PRECAUTION
Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.
After turning the ignition switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work.
Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>INITIALIZATION
Check for DTCs.
| Result | Proceed to |
|---|---|
| P0AFC00 or P0AFC96 is not output. | A |
| P0AFC00 or P0AFC96 is output. | B |
Turn the ignition switch off.
A
B
Check the DTCs that were output when the vehicle was brought to the workshop.
| Result | Proceed to |
|---|---|
| P0A8100 or P0A8115 is also output. | A |
| P0A9600 or P0A9615 is also output. | B |
A
B
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM (for 2WD)>P0A8111
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM (for 2WD)>P0A8111
| Proceed to |
|---|
| OK |
| NG |
OK
NG