Refer to the description for DTC P0C7396.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM (for 2WD)>P0C7396
The inverter water pump assembly sends the inverter water pump speed (measured value) signal to the hybrid vehicle control ECU.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Warning Indicate |
|---|---|---|---|---|---|
| P314A31 | Motor Electronics Coolant Pump "A" No Signal | The inverter water pump speed signal is not sent to the hybrid vehicle control ECU when the ignition switch is turned to ON (READY).*
(1 trip detection logic) |
·
Wire harness or connector ·
Hybrid vehicle control ECU ·
Inverter water pump assembly ·
INV W/PMP fuse ·
IGCT NO. 2 fuse ·
INV W/PMP relay |
Comes on | Master Warning:
Comes on |
A malfunction (open, short to +B or short to ground) in the speed signal line from the inverter water pump assembly to the hybrid vehicle control ECU is detected.
A malfunction in the +B line is detected.
A malfunction in the inverter water pump assembly power source circuit is detected.
A malfunction in hybrid vehicle control ECU power source circuit is detected.
| DTC No. | Data List |
|---|---|
| P314A31 | ·
Inverter Water Pump Revolution ·
Inverter Water Pump Duty Ratio ·
Ready Signal |
| DTC No. | Active Test |
|---|---|
| P314A31 | Activate the Inverter Water Pump |
After repair has been completed, clear the DTC and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM (for 2WD)>UTILITY
Connect the GTS to the DLC3.
Turn the ignition switch to ON and turn the GTS on.
Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).
Turn the ignition switch off and wait for 2 minutes or more.
Turn the ignition switch to ON and turn the GTS on.
Turn the ignition switch to ON (READY) and wait for 2 minutes or more.
Enter the following menus: Powertrain / Hybrid Control / Utility / All Readiness.
Check the DTC judgment result.
If the judgment result shows NORMAL, the system is normal.
If the judgment result shows ABNORMAL, the system has a malfunction.
If the judgment result shows INCOMPLETE, perform driving pattern again.
Refer to the wiring diagram for Cooling System.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM (for 2WD)>Cooling System
Read and record the DTCs and Freeze Frame Data.
Clear the DTCs and Freeze Frame Data.
Turn the ignition switch off and wait for 2 minutes or more.
| Proceed to |
|---|
| NEXT |
NEXT
Make sure that the HV coolant level is above the low line of the inverter reserve tank.
Be sure to perform the inspection with the auxiliary battery voltage at 12 V or more.
When the auxiliary battery voltage is low, the inverter water pump assembly may not operate.
When the inverter water pump assembly signal line (SWP - IWP) is open or its connection is faulty, the inverter water pump assembly is operated forcibly.
Perform the "Activate the Inverter Water Pump" Active Test.
| Tester Display |
|---|
| Activate the Inverter Water Pump |
Touch the inverter water pump assembly and check that it is operating (vibrating).
The inverter water pump is operating (vibrating).
Perform the Active Test with the inverter coolant temperature between -15 and 65°C (5 to 149°F).
Turn the ignition switch off.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM (for 2WD)>P056014
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM (for 2WD)>Cooling System
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the A31 hybrid vehicle control ECU connector.
Disconnect the A56 inverter water pump assembly connector.
| *a | Front view of wire harness connector
(to Hybrid Vehicle Control ECU) |
| *b | Front view of wire harness connector
(to Inverter Water Pump Assembly) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A31-33 (NIWP) - A56-2 (NWP) | Ignition switch off | Below 1 Ω |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A31-33 (NIWP) or A56-2 (NWP) - Body ground and other terminals | Ignition switch off | 10 kΩ or higher |
Check the condition (looseness, deterioration, etc.) of the wire to body ground for the inverter water pump assembly.
Reconnect the A56 inverter water pump assembly connector.
Reconnect the A31 hybrid vehicle control ECU connector.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the A56 inverter water pump assembly connector.
Turn the ignition switch to ON.
Measure the voltage according to the value(s) in the table below.
| *a | Component with harness connected
(Hybrid Vehicle Control ECU) |
- | - |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A31-33 (NIWP) - H67-3 (E1) | Ignition switch ON | 11 to 14 V |
Turn the ignition switch off.
Reconnect the A56 inverter water pump assembly connector.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM (for 2WD)>P06881F
| Proceed to |
|---|
| NEXT |
NEXT
Be sure to perform the inspection with the auxiliary battery voltage at 12 V or more.
When the auxiliary battery voltage is low, the inverter water pump assembly may not operate.
Perform the "Activate the Inverter Water Pump" Active Test.
| Tester Display |
|---|
| Activate the Inverter Water Pump |
Connect an oscilloscope between the hybrid vehicle control ECU terminals specified in the table below, and measure the waveform.
| *a | Component with harness connected
(Hybrid Vehicle Control ECU) |
- | - |
| Item | Content |
|---|---|
| Terminal | A31-33 (NIWP) - H67-3 (E1) |
| Equipment Setting | 5 V/DIV., 5 ms./DIV. |
| Condition | Ignition switch ON, during Active Test |
The period of the wavelength is 13 msec or less.
Turn the ignition switch off.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM (for 2WD)>Cooling System
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| *1 | No. 1 Engine Room Relay Block and No. 1 Junction Block Assembly |
| *2 | INV W/PMP Relay |
Check installation condition of the INV W/PMP relay.
INV W/PMP relay is installed correctly.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| *1 | No. 5 Floor Relay Block and No. 5 Floor Junction Block Assembly |
| *2 | IGCT Relay Holder |
Remove the IGCT relay from the No. 5 floor relay block and No. 5 floor junction block assembly.
| *1 | No. 1 Engine Room Relay Block and No. 1 Junction Block Assembly |
| *2 | INV W/PMP Relay Holder |
Remove the INV W/PMP relay from the No. 1 engine room relay block and No. 1 junction block assembly.
| *a | Example |
| *b | Shake Slightly |
| *c | Vibrate Slightly |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 5 (IGCT relay holder) - 1 (INV W/PMP relay holder) | Ignition switch off | Below 1 Ω |
Do not apply excessive force when using the probes of the tester to perform the inspection. If excessive force is used, the terminals will be damaged.
Connectors
Slightly shake the connector vertically and horizontally.
Wire Harness
Slightly shake the wire harness vertically and horizontally.
The connector joint and fulcrum of the vibration are the major areas that should be checked thoroughly.
No. 5 Floor Relay Block and No. 5 Floor Junction Block Assembly
Apply slight vibration with a finger to the No. 5 floor relay block and No. 5 floor junction block assembly and check whether a malfunction occurs.
No. 1 Engine Room Relay Block and No. 1 Junction Block Assembly
Apply slight vibration with a finger to the No. 1 engine room relay block and No. 1 junction block assembly and check whether a malfunction occurs.
IGCT NO. 2 fuse
Apply slight vibration with a finger to the IGCT NO. 2 fuse and check whether a malfunction occurs.
Install the IGCT relay and INV W/PMP relay.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| *1 | No. 1 Engine Room Relay Block and No. 1 Junction Block Assembly |
| *2 | INV W/PMP Relay |
Remove the INV W/PMP relay from the No. 1 engine room relay block and No. 1 junction block assembly.
| *1 | INV W/PMP Relay |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3 - 5 | Auxiliary battery voltage not applied between terminals 1 and 2 | 10 kΩ or higher |
| Auxiliary battery voltage applied between terminals 1 and 2 | Below 1 Ω |
Install the INV W/PMP relay.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| *a | Front view of wire harness connector
(to Inverter Water Pump Assembly) |
| *a | Example |
| *b | Shake Slightly |
| *c | Vibrate Slightly |
Disconnect the A56 inverter water pump assembly connector.
Turn the ignition switch to ON.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A56-4 (+BWP) - Body ground | Ignition switch ON | 11 to 14 V |
If the ignition switch is turned to ON with the connectors disconnected, other DTCs will be stored. Be sure to clear the DTCs after the inspection.
Do not apply excessive force when using the probes of the tester to perform the inspection. If excessive force is used, the terminals will be damaged.
Connectors
Slightly shake the connector vertically and horizontally.
Wire Harness
Slightly shake the wire harness vertically and horizontally.
The connector joint and fulcrum of the vibration are the major areas that should be checked thoroughly.
No. 1 Engine Room Relay Block and No. 1 Junction Block Assembly
Apply slight vibration with a finger to the No. 1 engine room relay block and No. 1 junction block assembly and check whether a malfunction occurs.
INV W/PMP fuse
Apply slight vibration with a finger to the INV W/PMP fuse and check whether a malfunction occurs.
INV W/PMP Relay
Apply slight vibration with a finger to the INV W/PMP relay and check whether a malfunction occurs.
Turn the ignition switch off.
Reconnect the A56 inverter water pump assembly connector.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the A56 inverter water pump assembly connector.
| *a | Front view of wire harness connector
(to Inverter Water Pump Assembly) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A56-1 (GND) - Body ground | Ignition switch off | Below 1 Ω |
Reconnect the A56 inverter water pump assembly connector.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>WATER PUMP WITH MOTOR>REMOVAL
| Proceed to |
|---|
| NEXT |
NEXT
After replacing the inverter water pump assembly, add HV coolant and perform air bleeding.
Click hereGeneral>MAINTENANCE>COOLANT (for Inverter)>REPLACEMENT
| Proceed to |
|---|
| NEXT |
NEXT
| *1 | No. 1 Engine Room Relay Block and No. 1 Junction Block Assembly |
| *2 | INV W/PMP Relay |
Remove the INV W/PMP relay from the No. 1 engine room relay block and No. 1 junction block assembly.
| *1 | INV W/PMP Relay |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3 - 5 | Auxiliary battery voltage not applied between terminals 1 and 2 | 10 kΩ or higher |
| Auxiliary battery voltage applied between terminals 1 and 2 | Below 1 Ω |
Install the INV W/PMP relay.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| *1 | No. 5 Floor Relay Block and No. 5 Floor Junction Block Assembly |
| *2 | IGCT NO. 2 Fuse |
Check installation condition of the IGCT NO. 2 fuse.
IGCT NO. 2 fuse is installed correctly.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| *1 | No. 5 Floor Relay Block and No. 5 Floor Junction Block Assembly |
| *2 | IGCT NO. 2 Fuse |
Remove the IGCT NO. 2 fuse from the No. 5 floor relay block and No. 5 floor junction block assembly.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| IGCT NO. 2 fuse | Always | Below 1 Ω |
Install the IGCT NO. 2 fuse.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| *1 | No. 1 Engine Room Relay Block and No. 1 Junction Block Assembly |
| *2 | INV W/PMP Relay |
Check the terminals of the INV W/PMP relay holder.
The terminals of the INV W/PMP relay holder are not bent, loose or corroded.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| *1 | No. 1 Engine Room Relay Block and No. 1 Junction Block Assembly |
| *2 | INV W/PMP Fuse |
Check installation condition of the INV W/PMP fuse.
INV W/PMP fuse is installed correctly.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| *1 | No. 1 Engine Room Relay Block and No. 1 Junction Block Assembly |
| *2 | INV W/PMP Relay |
Remove the INV W/PMP relay from the No. 1 engine room relay block and No. 1 junction block assembly.
| *1 | INV W/PMP Relay |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3 - 5 | Auxiliary battery voltage not applied between terminals 1 and 2 | 10 kΩ or higher |
| Auxiliary battery voltage applied between terminals 1 and 2 | Below 1 Ω |
Install the INV W/PMP relay.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Remove the INV W/PMP relay and INV W/PMP fuse from the No. 1 engine room relay block and No. 1 junction block assembly.
Disconnect the A56 inverter water pump assembly connector.
Measure the resistance according to the value(s) in the table below.
| *1 | No. 1 Engine Room Relay Block and No. 1 Junction Block Assembly | *2 | INV W/PMP Relay Holder |
| *3 | INV W/PMP Fuse | - | - |
| *a | Front view of wire harness connector
(to Inverter Water Pump Assembly) |
- | - |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A56-4 (+BWP) - 3 (INV W/PMP relay holder) | Ignition switch off | Below 1 Ω |
| 2 (INV W/PMP fuse holder) or A56-4 (+BWP) - Body ground and other terminals | Ignition switch off | 10 kΩ or higher |
Do not apply excessive force when using the probes of the tester to perform the inspection. If excessive force is used, the terminals will be damaged.
Reconnect the A56 inverter water pump assembly connector.
Install the INV W/PMP relay and INV W/PMP fuse.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| *1 | No. 1 Engine Room Relay Block and No. 1 Junction Block Assembly |
| *2 | INV W/PMP Fuse |
Remove the INV W/PMP fuse from the No. 1 engine room relay block and No. 1 junction block assembly.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| INV W/PMP fuse | Always | Below 1 Ω |
Install the INV W/PMP fuse.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| *1 | No. 1 Engine Room Relay Block and No. 1 Junction Block Assembly |
| *2 | INV W/PMP Relay |
Remove the INV W/PMP relay from the No. 1 engine room relay block and No. 1 junction block assembly.
| *1 | INV W/PMP Relay |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3 - 5 | Auxiliary battery voltage not applied between terminals 1 and 2 | 10 kΩ or higher |
| Auxiliary battery voltage applied between terminals 1 and 2 | Below 1 Ω |
Install the INV W/PMP relay.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| *1 | No. 5 Floor Relay Block and No. 5 Floor Junction Block Assembly |
| *2 | IGCT NO. 2 Fuse |
Check the terminals of the IGCT NO. 2 fuse holder.
The terminals of the IGCT NO. 2 fuse holder are not bent, loose or corroded.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Repair or replace the terminals of the INV W/PMP relay holder.
| Proceed to |
|---|
| NEXT |
NEXT
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>WATER PUMP WITH MOTOR>REMOVAL
| Proceed to |
|---|
| NEXT |
NEXT
After replacing the inverter water pump assembly, add HV coolant and perform air bleeding.
Click hereGeneral>MAINTENANCE>COOLANT (for Inverter)>REPLACEMENT
| Proceed to |
|---|
| NEXT |
NEXT
| Proceed to |
|---|
| NEXT |
NEXT
Repair or replace the terminals of the IGCT NO. 2 fuse holder.
| Proceed to |
|---|
| NEXT |
NEXT
| *1 | No. 1 Engine Room Relay Block and No. 1 Junction Block Assembly |
| *2 | INV W/PMP Relay |
Check the terminals of the INV W/PMP relay holder.
The terminals of the INV W/PMP relay holder are not bent, loose or corroded.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| *1 | No. 5 Floor Relay Block and No. 5 Floor Junction Block Assembly |
| *2 | IGCT NO. 2 Fuse |
Remove the IGCT NO. 2 fuse from the No. 5 floor relay block and No. 5 floor junction block assembly.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| IGCT NO. 2 fuse | Always | Below 1 Ω |
Install the IGCT NO. 2 fuse.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| *1 | No. 5 Floor Relay Block and No. 5 Floor Junction Block Assembly |
| *2 | IGCT NO. 2 Fuse |
Remove the IGCT NO. 2 fuse from the No. 5 floor relay block and No. 5 floor junction block assembly.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| IGCT NO. 2 fuse | Always | Below 1 Ω |
Install the IGCT NO. 2 fuse.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Repair or replace the terminals of the INV W/PMP relay holder.
| Proceed to |
|---|
| NEXT |
NEXT
| Proceed to |
|---|
| NEXT |
NEXT
Repair or replace the terminals of the INV W/PMP relay holder.
| Proceed to |
|---|
| NEXT |
NEXT
| Proceed to |
|---|
| NEXT |
NEXT