Home › Engine / Hybrid System › HYBRID / BATTERY CONTROL › HYBRID CONTROL SYSTEM (for 4WD/AWD)
RM37A0E _51 Engine / Hybrid System _086850 HYBRID / BATTERY CONTROL _0420994 HYBRID CONTROL SYSTEM(for 4WD/AWD) J

HYBRID / BATTERY CONTROL  HYBRID CONTROL SYSTEM(for 4WD/AWD)  HV Battery High-voltage Line Circuit  


DESCRIPTION

The cause of the malfunction may be the HV battery high-voltage line circuit.

Check the continuity in the high-voltage line from the HV battery to the inverter.

Check the connection condition and for an open circuit in the frame wire from the service plug grip, EV electric battery fuse and HV battery to the inverter and perform a function check of the system main relay.

Related Parts Check
Area Inspection
High-voltage circuit from HV battery to inverter Check connection condition and for open circuit.
Service plug grip Check connection condition and for open circuit.
EV electric battery fuse Check for open circuit.
System Main Relay Check operation condition as relay.

SYSTEM DESCRIPTION

The HV battery high voltage is supplied to the inverter via the system main relay operation.

WIRING DIAGRAM

A454577E03
0.135,3.385 0.927,4.021 0.792,0.635 10 false Service Plug Grip 0.135,1.677 1.073,2.333 0.938,0.656 10 false Hybrid Battery Terminal Block 0.313,2.719 1.844,2.917 1.531,0.198 10 false HV Battery 1.49,0.927 1.771,1.146 0.281,0.219 10 false z11 1.573,0.76 1.729,0.958 0.156,0.198 10 false 1 0.979,1.448 1.135,1.646 0.156,0.198 10 false 1 0.99,2.125 1.146,2.323 0.156,0.198 10 false 1 1.563,3.688 1.719,3.885 0.156,0.198 10 false 1 1.167,1.427 1.625,1.625 0.458,0.198 10 false z10 1.177,2.125 1.635,2.323 0.458,0.198 10 false z14 1.5,3.875 1.958,4.073 0.458,0.198 10 false z9 1.844,0.792 2,0.99 0.156,0.198 10 false + 1.833,3.719 1.99,3.917 0.156,0.198 10 false - 2.802,1.594 3.417,1.792 0.615,0.198 10 false SMRB 3.875,1.26 4.49,1.458 0.615,0.198 10 false SMRB 6.208,4.708 6.823,4.906 0.615,0.198 10 false SMRB 2.792,4.531 3.406,4.729 0.615,0.198 10 false SMRG 3.885,4.208 4.5,4.406 0.615,0.198 10 false SMRG 6.198,5.198 6.813,5.396 0.615,0.198 10 false SMRG 2.802,5.958 3.417,6.156 0.615,0.198 10 false SMRP 6.208,5.635 6.823,5.833 0.615,0.198 10 false SMRP 3.896,5.625 4.51,5.823 0.615,0.198 10 false SMRP 4,6.115 4.458,6.313 0.458,0.198 10 false GND 1.917,6.667 4.333,6.948 2.417,0.281 10 false HV Battery Junction Block Assembly 4.042,0.781 4.5,0.979 0.458,0.198 10 false CBI 4.052,3.74 4.51,3.938 0.458,0.198 10 false CEI 4.406,0.927 4.719,1.125 0.313,0.198 10 false k2 4.354,1.375 4.813,1.573 0.458,0.198 10 false M56 4.406,3.885 4.719,4.083 0.313,0.198 10 false k3 4.365,4.323 4.823,4.521 0.458,0.198 10 false M56 4.365,5.74 4.823,5.938 0.458,0.198 10 false M56 4.365,6.198 4.823,6.396 0.458,0.198 10 false M56 4.458,0.74 4.615,0.938 0.156,0.198 10 false 1 4.448,1.188 4.604,1.385 0.156,0.198 10 false 1 4.458,3.698 4.615,3.896 0.156,0.198 10 false 1 4.458,4.146 4.615,4.344 0.156,0.198 10 false 4 4.448,5.552 4.604,5.75 0.156,0.198 10 false 2 4.458,6.021 4.615,6.219 0.156,0.198 10 false 3 5.969,4.708 6.229,4.948 0.26,0.24 10 false 16 5.979,5.188 6.24,5.427 0.26,0.24 10 false 13 5.99,5.625 6.25,5.865 0.26,0.24 10 false 15 5.438,6.625 5.75,6.823 0.313,0.198 10 false A32 5.448,6.823 7.156,7.24 1.708,0.417 10 false Hybrid Vehicle Control ECU 6.292,0.917 6.75,1.115 0.458,0.198 10 false CBI 6.302,1.792 6.76,1.99 0.458,0.198 10 false CEI 6.104,0.781 6.26,0.979 0.156,0.198 10 false 1 6.115,1.646 6.271,1.844 0.156,0.198 10 false 2 5.781,2.24 6.094,2.438 0.313,0.198 10 false k1 5.781,2.406 7.156,3.031 1.375,0.625 10 false Inverter with Converter Assembly 1.219,7.344 5.042,7.542 3.823,0.198 10 false : HV Battery Voltage Line 3.188,7.344 4.625,7.583 1.438,0.24 10 false *: with Monitor Circuit 6.896,4.771 7.052,4.969 0.156,0.198 10 false * 6.885,5.219 7.042,5.417 0.156,0.198 10 false * 6.896,5.698 7.052,5.896 0.156,0.198 10 false * 1.021,3.177 1.177,3.375 0.156,0.198 10 false 1 1.021,3.76 1.177,3.958 0.156,0.198 10 false 2 5.729,6.354 6.042,6.552 0.313,0.198 10 false MF

CAUTION / NOTICE / HINT

This diagnostic procedure is referenced to in the diagnostic procedure of several DTCs.

If the result of this diagnostic procedure is normal, proceed as directed in the procedure for the DTC.

CAUTION:
·
A340358

Before the following operations are conducted, take precautions to prevent electric shock by turning the ignition switch off, wearing insulated gloves, and removing the service plug grip from HV battery.

-

Inspecting the high-voltage system

-

Disconnecting the low voltage connector of the inverter with converter assembly

-

Disconnecting the low voltage connector of the HV battery


·
A357588

To prevent electric shock, make sure to remove the service plug grip to cut off the high voltage circuit before servicing the vehicle.

·
A358042

After removing the service plug grip from the HV battery, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.

·
A357589C44
1.573,0.74 2.021,0.427 true 2.094,0.344 2.354,0.51 0.26,0.167 10 false *a
*a Without waiting for 10 minutes


After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM (for 4WD/AWD)>PRECAUTION

HINT:

Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.




NOTICE:

After turning the ignition switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work.

Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>INITIALIZATION


PROCEDURE

1.CHECK INVERTER WITH CONVERTER ASSEMBLY (HV FLOOR UNDER WIRE CONNECTION CONDITION)
CAUTION:

Be sure to wear insulated gloves.


a.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.



b.
C412485

Check that the bolts for the HV floor under wire is tightened to the specified torque, the HV floor under wire is connected securely, and there are no contact problems.

Specified Condition:

T = 8.0 N*m (82 kgf*cm, 71 in.*lbf)



c.

Disconnect the HV floor under wire from the inverter with converter assembly.


d.

Check for arc marks on the terminals for the HV floor under wire and inverter with converter assembly.

Result:
Result Proceed to
The terminals are connected securely and there are no contact problems. There are no arc marks. A
The terminals are not connected securely and there is a contact problem. There are arc marks. B
The terminals are not connected securely and there is a contact problem. There are no arc marks. C
The terminals are connected securely and there are no contact problems. There are arc marks. B



e.

Reconnect the HV floor under wire.



A

2.CHECK SERVICE PLUG GRIP (CONNECTION CONDITION)

B

REPLACE MALFUNCTIONING PARTS

C

CONNECT SECURELY

2.CHECK SERVICE PLUG GRIP (CONNECTION CONDITION)
CAUTION:

Be sure to wear insulated gloves.


a.

Visually check the connection of the service plug grip to the HV battery. Remove the service plug grip and check for contamination.

OK:

Dirt or foreign matter has not entered the connectors, and there is no evidence of contamination.



b.

Install the service plug grip.


Result:
Proceed to
OK
NG



OK

3.INSPECT SERVICE PLUG GRIP

NG

3.INSPECT SERVICE PLUG GRIP
CAUTION:

Be sure to wear insulated gloves.



b.
A365294C01
0.104,0.083 0.417,0.24 0.313,0.156 10 false *1
*1 Service Plug Grip


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
Service plug grip terminals Always Below 1 Ω



c.

Install the service plug grip.


Result:
Proceed to
OK
NG



OK

4.CHECK HYBRID BATTERY TERMINAL BLOCK

NG

4.CHECK HYBRID BATTERY TERMINAL BLOCK
CAUTION:

Be sure to wear insulated gloves and protective goggles.


a.

Remove the Hybrid battery terminal block.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>FUSE BOX>REMOVAL


b.
A367707C01
0.104,0.083 0.417,0.24 0.313,0.156 10 false *1
*1 Hybrid Battery Terminal Block


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
Hybrid battery terminal block Always Below 1 Ω



c.

Install the Hybrid battery terminal block.


Result:
Proceed to
OK
NG



OK

5.CHECK HV BATTERY JUNCTION BLOCK ASSEMBLY (HV FLOOR UNDER WIRE CONNECTION CONDITION)

NG

REPLACE HYBRID BATTERY TERMINAL BLOCK

5.CHECK HV BATTERY JUNCTION BLOCK ASSEMBLY (HV FLOOR UNDER WIRE CONNECTION CONDITION)
CAUTION:

Be sure to wear insulated gloves.


a.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.



b.

Remove the No. 10 HV battery shield panel.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HV BATTERY>REMOVAL


c.
A454534N01
0.781,1.354 1.125,1.594 0.344,0.24 1.865,1.802 2.26,2.042 0.396,0.24 0.823,1.375 1.115,1.573 0.292,0.198 10 true k2 1.917,1.823 2.229,2.021 0.313,0.198 10 true k3

Check that the HV floor under wire is connected securely, and there are no contact problems.


d.

Disconnect the HV floor under wire connectors from the HV battery junction block assembly.


e.

Check for arc marks on the terminals of the HV floor under wire and the HV battery junction block assembly.

Result:
Result Proceed to
The terminals are connected securely and there are no contact problems. There are no arc marks. A
The terminals are not connected securely and there is a contact problem. There are arc marks. B
The terminals are not connected securely and there is a contact problem. There are no arc marks. C
The terminals are connected securely and there are no contact problems. There are arc marks. B



f.

Reconnect the HV floor under wire.


g.

Install the No. 10 HV battery shield panel.



A

6.CHECK FLOOR UNDER WIRE

B

REPLACE MALFUNCTIONING PARTS

C

CONNECT SECURELY

6.CHECK FLOOR UNDER WIRE
CAUTION:

Be sure to wear insulated gloves.


a.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.



b.

Remove the No. 10 HV battery shield panel.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HV BATTERY>REMOVAL


c.
A454534N01
0.781,1.354 1.125,1.594 0.344,0.24 1.865,1.802 2.26,2.042 0.396,0.24 0.823,1.375 1.115,1.573 0.292,0.198 10 true k2 1.917,1.823 2.229,2.021 0.313,0.198 10 true k3

Disconnect the HV floor under wire connectors from the HV battery junction block assembly.


d.
C412478N01
2.063,1.26 2.417,1.49 0.354,0.229 2.083,1.281 2.396,1.479 0.313,0.198 10 true k1

Disconnect the HV floor under wire connector from the inverter with converter assembly.


e.

Measure the resistance according to the value(s) in the table below.

A455379C02
1.896,0.417 2.198,0.667 0.302,0.25 4.885,2.135 5.188,2.385 0.302,0.25 3.531,2.146 3.833,2.396 0.302,0.25 2.208,1.156 2.708,1.438 true 1.396,1.469 1.906,1.156 true 3.615,2.594 4.083,2.438 true 4.625,2.458 5.01,2.604 true 1.396,0.896 1.594,0.833 true 5.677,1.25 5.948,1.479 true 0.333,0.219 0.646,0.417 0.313,0.198 10 false *a 3.667,0.208 3.979,0.406 0.313,0.198 10 false *b 1.969,0.469 2.281,0.667 0.313,0.198 10 false k1 1.135,1.396 1.5,1.615 0.365,0.219 10 false CBI 2.76,1.406 3.125,1.625 0.365,0.219 10 false CEI 4.969,2.188 5.281,2.385 0.313,0.198 10 false k3 3.604,2.198 3.917,2.396 0.313,0.198 10 false k2 3.365,2.521 3.729,2.74 0.365,0.219 10 false CBI 5.052,2.542 5.417,2.76 0.365,0.219 10 false CEI 1.167,0.833 1.531,1.052 0.365,0.219 10 false *1 5.99,1.417 6.354,1.635 0.365,0.219 10 false *1
*1 Shield Ground - -
*a HV Floor Under Wire
(Inverter with Converter Assembly Side)
*b HV Floor Under Wire
(HV Battery Junction Block Assembly Side)


Standard Resistance:
Tester Connection Condition Specified Condition
k1-1 (CBI) - k2-1 (CBI) Ignition switch off Below 1 Ω
k1-2 (CEI) - k3-1 (CEI) Ignition switch off Below 1 Ω


NOTICE:

Be sure not to damage or deform the terminal being inspected.



f.

Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.

NOTICE:

Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.


Standard Resistance:
Tester Connection Condition Specified Condition
k1-1 (CBI) or k2-1(CBI) - Body ground and shield ground Ignition switch off 10 MΩ or higher
k1-2 (CEI) or k3-1(CEI) - Body ground and shield ground Ignition switch off 10 MΩ or higher
k1-1 (CBI) - k1-2 (CEI) Ignition switch off 10 MΩ or higher
k2-1 (CBI) - k3-1 (CEI) Ignition switch off 10 MΩ or higher



g.

Reconnect the HV floor under wire connector to the inverter with converter assembly.


h.

Reconnect the HV floor under wire connectors to the HV battery junction block assembly.


i.

Install the No. 10 HV battery shield panel.


Result:
Proceed to
OK
NG



OK

7.INSPECT HV BATTERY JUNCTION BLOCK ASSEMBLY (SMRB)

NG

7.INSPECT HV BATTERY JUNCTION BLOCK ASSEMBLY (SMRB)
CAUTION:

Be sure to wear insulated gloves.


a.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.



b.

Remove the HV battery junction block assembly.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HV RELAY ASSEMBLY>REMOVAL


c.

Measure the resistance according to the value(s) in the table below.

C384277C40
3.76,1.031 4.115,1.24 0.354,0.208 5.625,0.146 6.031,0.375 0.406,0.229 3.302,0.146 3.656,0.365 0.354,0.219 3.125,1.406 3.396,1.24 true 3.792,1.417 3.625,1.24 true 3.771,0.427 3.396,0.677 true 6.292,0.698 5.802,0.698 true 0.573,0.146 0.885,0.302 0.313,0.156 10 false *a 3.823,1.063 4.281,1.26 0.458,0.198 10 false M56 2.958,1.438 3.292,1.646 0.333,0.208 10 true GND 3.677,1.417 4.156,1.625 0.479,0.208 10 true SMRB 5.688,0.167 6,0.365 0.313,0.198 10 true z11 6.323,0.604 6.479,0.802 0.156,0.198 10 false + 3.375,0.188 3.583,0.333 0.208,0.146 10 true k2 3.813,0.344 4.198,0.563 0.385,0.219 10 false CBI
*a Component without harness connected
(HV Battery Junction Block Assembly)
- -


Standard Resistance:
Tester Connection Condition Specified Condition
z11-1 (+) - k2-1 (CBI) Auxiliary battery voltage not applied between terminals M56-1 (SMRB) and M56-3 (GND) 10 kΩ or higher
z11-1 (+) - k2-1 (CBI) Auxiliary battery voltage applied between terminals M56-1 (SMRB) and M56-3 (GND) Below 1 Ω



d.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
M56-1 (SMRB) - M56-3 (GND) -40 to 80°C (-40 to 176°F) 25.0 to 59.0 Ω



e.

Install the HV battery junction block assembly.


Result:
Proceed to
OK
NG



OK

8.INSPECT HV BATTERY JUNCTION BLOCK ASSEMBLY (SMRG)

NG

REPLACE HV BATTERY JUNCTION BLOCK ASSEMBLY

8.INSPECT HV BATTERY JUNCTION BLOCK ASSEMBLY (SMRG)
CAUTION:

Be sure to wear insulated gloves.


a.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.



b.

Remove the HV battery junction block assembly.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HV RELAY ASSEMBLY>REMOVAL


c.

Measure the resistance according to the value(s) in the table below.

C384277C41
3.76,1.031 4.115,1.24 0.354,0.208 2.219,0.104 2.583,0.344 0.365,0.24 1.167,0.115 1.531,0.323 0.365,0.208 3.469,1.479 3.427,1.25 true 3.01,1.5 3.323,1.25 true 2.063,1.063 2.396,0.677 true 0.833,0.854 1.344,0.656 true 0.573,0.146 0.885,0.302 0.313,0.156 10 false *a 3.823,1.052 4.281,1.25 0.458,0.198 10 false M56 3.365,1.51 3.698,1.719 0.333,0.208 10 true GND 2.771,1.51 3.219,1.708 0.448,0.198 10 true SMRG 2.281,0.156 2.552,0.313 0.271,0.156 10 true k3 1.229,0.135 1.5,0.302 0.271,0.167 10 true z9 1.813,1 2.188,1.208 0.375,0.208 10 false CEI 0.719,0.781 0.875,0.979 0.156,0.198 10 false -
*a Component without harness connected
(HV Battery Junction Block Assembly)
- -


Standard Resistance:
Tester Connection Condition Specified Condition
z9-1 (-) - k3-1 (CEI) Auxiliary battery voltage not applied between terminals M56-4 (SMRG) and M56-3 (GND) 10 kΩ or higher
z9-1 (-) - k3-1 (CEI) Auxiliary battery voltage applied between terminals M56-4 (SMRG) and M56-3 (GND) Below 1 Ω



d.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
M56-4 (SMRG) - M56-3 (GND) -40 to 80°C (-40 to 176°F) 25.0 to 59.0 Ω



e.

Install the HV battery junction block assembly.


Result:
Proceed to
OK
NG



OK

HV BATTERY HIGH-VOLTAGE LINE CIRCUIT NORMAL (PERFORM NEXT STEP FOR REFERENCED DTC)

NG

REPLACE HV BATTERY JUNCTION BLOCK ASSEMBLY