MALFUNCTION DESCRIPTION
This DTC is stored when a short is detected in the inverter with converter assembly (generator inverter) or the hybrid vehicle transaxle assembly (generator (MG1)). The cause of this malfunction may be one of the following:
Generator inverter internal circuit malfunction
Open or short circuit
Damage from iron particles or other foreign objects
For a description of the inverter.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>MOTOR GENERATOR CONTROL SYSTEM (for 4WD/AWD)>P0D2D16
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Warning Indicate |
|---|---|---|---|---|---|
| P0A7A73 | Generator Inverter Actuator Stuck Closed | Current flow to any phase of the generator (MG1) exceeds the threshold after the generator inverter is shut down due to a DTC indicating a generator inverter malfunction (overheating, overcurrent or circuit malfunction) being stored.
(1 trip detection logic) |
·
Inverter with converter assembly ·
Motor cable ·
Hybrid vehicle transaxle assembly |
Comes on | Master Warning:
Comes on |
After repair has been completed, clear the DTC and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>MOTOR GENERATOR CONTROL SYSTEM (for 4WD/AWD)>UTILITY
Connect the GTS to the DLC3.
Turn the ignition switch to ON and turn the GTS on.
Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).
Turn the ignition switch off and wait for 2 minutes or more.
Turn the ignition switch to ON and turn the GTS on.
With ignition switch ON and wait for 5 seconds or more.
Turn the ignition switch to ON (READY) and wait for 5 seconds or more.
Check that there are no abnormalities (abnormal sounds, coolant leaks, etc.).
Drive the vehicle for approximately 10 minutes mainly using the engine.
As the state of charge of the HV battery may be low after driving in fail-safe mode, it will automatically be charged for 5 to 10 minutes with ignition switch ON (READY) after repairs have been performed.
Enter the following menus: Powertrain / Motor Generator / Utility / All Readiness.
Check the DTC judgment result.
If the judgment result shows NORMAL, the system is normal.
If the judgment result shows ABNORMAL, the system has a malfunction.
If the judgment result shows INCOMPLETE, perform driving pattern again.
Refer to the wiring diagram for the Generator High-voltage Circuit.
Before the following operations are conducted, take precautions to prevent electric shock by turning the ignition switch off, wearing insulated gloves, and removing the service plug grip from HV battery.
Inspecting the high-voltage system
Disconnecting the low voltage connector of the inverter with converter assembly
Disconnecting the low voltage connector of the HV battery
To prevent electric shock, make sure to remove the service plug grip to cut off the high voltage circuit before servicing the vehicle.
After removing the service plug grip from the HV battery, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
| *a | Without waiting for 10 minutes |
After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.
Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.
After turning the ignition switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work.
Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>INITIALIZATION
DTC P0A7A73 is stored after DTC P0A7A9E and/or P1C5F19 is stored. After troubleshooting and repairing the malfunction which caused DTC P0A7A73 to be stored, be sure to troubleshoot the other DTCs.
Depending on the conditions in which the vehicle is being operated when a short circuit occurs in the inverter with converter assembly, the hybrid vehicle transaxle assembly may be affected. As this DTC is stored if a short circuit occurs in the inverter with converter assembly, it is necessary to perform a road test to check the hybrid vehicle transaxle assembly. If problems are found, replace the malfunctioning parts.
After completing the repair, including the repair of previously output DTCs, drive the vehicle at a speed of approximately 40 km/h (25 mph) for 1 minute and check that DTC P0A92000 is not output. If DTC P0A92000 is output, replace the hybrid vehicle transaxle assembly.
Check for DTCs.
| Result | Proceed to |
|---|---|
| P0A7A73 only is output, or DTCs except the ones in the table below are also output. | A |
| Any of the following DTCs are also output. | B |
| Malfunction Content | Relevant DTC | |
|---|---|---|
| Insulation Malfunction | P1C7C49 | Hybrid/EV Battery Voltage System Isolation (A/C Area) Internal Electronic Failure |
| P1C7D49 | Hybrid/EV Battery Voltage System Isolation (Hybrid/EV Battery Area) Internal Electronic Failure | |
| P1C7E49 | Hybrid/EV Battery Voltage System Isolation (Transaxle Area) Internal Electronic Failure | |
| P1C7F49 | Hybrid/EV Battery Voltage System Isolation (Direct Current Area) Internal Electronic Failure | |
| P1C8049 | Hybrid/EV Battery Voltage System Isolation (Rear Motor Area) Internal Electronic Failure | |
P0A7A73 may be output as a result of the malfunctions indicated by the DTCs above.
The chart above is listed in inspection order of priority.
Check DTCs that are output at the same time by following the listed order. (The main cause of the malfunction can be determined without performing unnecessary inspections.)
Turn the ignition switch off.
A
B
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>INVERTER WITH CONVERTER>REMOVAL
| Proceed to |
|---|
| NEXT |
NEXT
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Click hereDrivetrain>P810 (HYBRID TRANSMISSION / TRANSAXLE)>HYBRID VEHICLE TRANSAXLE>REMOVAL
| Proceed to |
|---|
| NEXT |
NEXT
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>INVERTER WITH CONVERTER>REMOVAL
| Proceed to |
|---|
| NEXT |
NEXT
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the ignition switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Disconnect the motor cable from the hybrid vehicle transaxle assembly.
| *a | Motor Cable not connected
(Hybrid Vehicle Transaxle Assembly) |
Check the generator (MG1) for an interphase short using a milliohmmeter.
Using a milliohmmeter, measure the resistance according to the value(s) in the table below.
If the generator (MG1) temperature is high, the resistance will vary greatly from the specification. Therefore, measure the resistance at least 8 hours after the vehicle has been stopped.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| w1-4 (W) - w1-5 (U) | Ignition switch off | 25.7 to 28.5 mΩ |
| w1-5 (U) - w1-6 (V) | Ignition switch off | 25.7 to 28.5 mΩ |
| w1-4 (W) - w1-6 (V) | Ignition switch off | 25.8 to 28.6 mΩ |
To correct the variation of the measured resistance due to temperature, use the following formula to calculate the resistance at 20°C (68°F).
R20 = Rt / {1 + 0.00393 X (T - 20)}
The calculation is based on the following:
R20: Resistance at 20°C (68°F) (mΩ)
Rt: Measured resistance (mΩ)
T: Temperature when the resistance is measured (°C)
Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.
Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| w1-4 (W) - Body ground and shield ground | Ignition switch off | 100 MΩ or higher |
| w1-5 (U) - Body ground and shield ground | Ignition switch off | 100 MΩ or higher |
| w1-6 (V) - Body ground and shield ground | Ignition switch off | 100 MΩ or higher |
Connect the motor cable.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Click hereDrivetrain>P810 (HYBRID TRANSMISSION / TRANSAXLE)>MOTOR CABLE>REMOVAL
| Proceed to |
|---|
| NEXT |
NEXT
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>INVERTER WITH CONVERTER>REMOVAL
| Proceed to |
|---|
| NEXT |
NEXT
Click hereDrivetrain>P810 (HYBRID TRANSMISSION / TRANSAXLE)>MOTOR CABLE>REMOVAL
| Proceed to |
|---|
| NEXT |
NEXT
Click hereDrivetrain>P810 (HYBRID TRANSMISSION / TRANSAXLE)>HYBRID VEHICLE TRANSAXLE>REMOVAL
| Proceed to |
|---|
| NEXT |
NEXT
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>INVERTER WITH CONVERTER>REMOVAL
| Proceed to |
|---|
| NEXT |
NEXT
Check the other DTCs that were output together with DTC P0A7A73.
| Relevant DTC | |
|---|---|
| P0A7A9E | Generator Inverter Stuck On |
| P1C5F19 | Generator Inverter Circuit Current Above Threshold |
DTC P0A7A73 is stored after DTC P0A7A9E and/or P1C5F19 is stored. After troubleshooting and repairing the malfunction which caused DTC P0A7A73 to be stored, be sure to troubleshoot the other DTCs.
| Proceed to |
|---|
| NEXT |
NEXT