HEATING / AIR CONDITIONING  AIR CONDITIONING SYSTEM(for HV Model)  TERMINALS OF ECU  


CHECK AIR CONDITIONING AMPLIFIER ASSEMBLY


E432738E03
0.698,0.448 1.115,0.698 0.417,0.25 2.177,0.448 2.594,0.698 0.417,0.25 3.688,0.448 4.104,0.698 0.417,0.25 5.135,0.448 5.552,0.698 0.417,0.25 6.323,0.458 6.74,0.708 0.417,0.25 6.417,0.5 6.76,0.708 0.344,0.208 10 false z19 5.219,0.5 5.563,0.708 0.344,0.208 10 false H62 3.781,0.5 4.125,0.708 0.344,0.208 10 false H63 2.271,0.5 2.615,0.708 0.344,0.208 10 false H64 0.792,0.5 1.135,0.708 0.344,0.208 10 false H65

HINT:

Check from the rear of the connector while it is connected to the air conditioning amplifier assembly.


Channel 1 (z19)
Terminal No.
(Symbol)
Terminal Description Condition Specified Condition
z19-2 (BUS G) - Body ground Ground for BUS IC Always Below 1 V
z19-3 (BUS) - z19-2 (BUS G) BUS IC control signal Ignition switch ON Pulse generation
(See waveform "Servo LIN communication")
z19-4 (B BUS) - z19-2 (BUS G) Power supply for BUS IC Ignition switch off 11 to 14 V
z19-5 (SG) - Body ground Ground for evaporator temp. sensor (No. 1 cooler thermistor) Always Below 1 V
z19-6 (TE) - z19-5 (SG) Evaporator temp. sensor (No. 1 cooler thermistor) signal
·

Ignition switch ON

·

Evaporator temperature: 0°C (32°F)


1.7 to 2.1 V
·

Ignition switch ON

·

Evaporator temperature: 15°C (59°F)


0.9 to 1.3 V

Channel 2 (H62)
Terminal No.
(Symbol)
Terminal Description Condition Specified Condition
H62-2 (CANH) - H62-1 (CANL) CAN communication system CAN communication is performed Pulse generation
H62-5 (B) - H62-17 (GND) Power source (Back-up) Ignition switch off 11 to 14 V
H62-6 (IG+) - H62-17 (GND) Power source (IG) Ignition switch ON 11 to 14 V
Ignition switch off Below 1 V
H62-7 (LIN1) - H62-17 (GND) LIN communication signal Ignition switch ON Pulse generation
(See waveform "Control panel LIN communication")
H62-17 (GND) - Body ground Ground for main power supply Always Below 1 V
H62-21 (BLW) - H62-17 (GND) Blower motor speed control signal
·

Ignition switch ON

·

Blower switch: LO


Pulse generation
(See waveform "Blower")

Channel 3 (H63)
Terminal No.
(Symbol)
Terminal Description Condition Specified Condition
H63-1 (TAM) - H63-15 (SG-4) Ambient temp. sensor (thermistor assembly) signal
·

Ignition switch ON

·

Ambient temperature: 25°C (77°F)


1.05 to 1.45 V
·

Ignition switch ON

·

Ambient temperature: 40°C (104°F)


0.64 to 0.87 V
H63-3 (SG-1) - Body ground Ground for room temp. sensor (cooler thermistor) Always Below 1 V
H63-5 (TR) - H63-3 (SG-1) Room temp. sensor (cooler thermistor) signal
·

Ignition switch ON

·

Cabin temperature: 25°C (77°F)


1.05 to 1.45 V
·

Ignition switch ON

·

Cabin temperature: 40°C (104°F)


0.64 to 0.87 V
H63-6 (PRE) - H63-15 (SG-4) Air conditioner pressure sensor signal
·

Ignition switch ON (READY)

·

Air conditioning system operating

·

Refrigerant pressure: Abnormal pressure (more than 3025 kPaG (30.8 kgf/cm2, 439 psi))


4.61 V or higher
·

Ignition switch ON (READY)

·

Air conditioning system operating

·

Refrigerant pressure: Abnormal pressure (less than 176 kPaG (1.8 kgf/cm2, 26 psi))


Below 0.74 V
·

Ignition switch ON (READY)

·

Air conditioning system operating

·

Refrigerant pressure: Normal pressure (less than 3025 kPaG (30.8 kgf/cm2, 439 psi) and more than 176 kPaG (1.8 kgf/cm2, 26 psi))


0.74 to 4.61 V
H63-11 (S5-3) - H63-15 (SG-4) Power supply for air conditioner pressure sensor Ignition switch ON 4.75 to 5.25 V
Ignition switch off Below 1 V
H63-15 (SG-4) - Body ground Ground for air conditioner pressure sensor Always Below 1 V

Channel 4 (H64)
Terminal No.
(Symbol)
Terminal Description Condition Specified Condition
H64-1 (+B2) - H62-17 (GND) Power source (Back-up) Ignition switch off 11 to 14 V
H64-2 (RBBU) - H64-3 (RBUG) Power supply for BUS IC Ignition switch off 11 to 14 V
H64-3 (RBUG) - Body ground Ground for BUS IC Always Below 1 V
H64-4 (GND2) - Body ground Ground for main power supply Always Below 1 V
H64-7 (RBUS) - H64-3 (RBUG) BUS IC control signal Ignition switch ON Pulse generation
(See waveform "Servo LIN communication")
H64-10 (SBLW) - H62-17 (GND) Blower motor speed control signal
·

Ignition switch ON

·

Blower switch: LO


Pulse generation
(See waveform "Blower")
H64-20 (RLIN) - H62-17 (GND) LIN communication signal Ignition switch ON Pulse generation
(See waveform "Control panel LIN communication")

Channel 5 (H65)
Terminal No.
(Symbol)
Terminal Description Condition Specified Condition
H65-8 (TR) - H65-14 (SG-8) No. 2 room temp. sensor (cooler thermistor) signal
·

Ignition switch ON

·

Cabin temperature: 25°C (77°F)


1.05 to 1.45 V
·

Ignition switch ON

·

Cabin temperature: 40°C (104°F)


0.64 to 0.87 V
H65-11 (TEC) - H65-15 (SG-9) Rear evaporator temp. sensor (No. 2 air conditioning harness assembly) signal
·

Ignition switch ON

·

Evaporator temperature: 0°C (32°F)


1.7 to 2.1 V
·

Ignition switch ON

·

Evaporator temperature: 15°C (59°F)


0.9 to 1.3 V
H65-14 (SG-8) - Body ground Ground for No. 2 room temp. sensor (cooler thermistor) Always Below 1 V
H65-15 (SG-9) - Body ground Ground for Rear evaporator temp. sensor (No. 2 air conditioning harness assembly) Always Below 1 V

a.
E338778N01
2.823,1.24 3.281,1.438 0.458,0.198 10 false GND

Waveform "Blower":

Item Content
Terminal No.
·

H62-21 (BLW) - H62-17 (GND)

·

H64-10 (SBLW) - H62-17 (GND)


Tool Setting 2 V/DIV., 1 ms./DIV.
Condition
·

Ignition switch ON

·

Blower switch: LO




b.
E334619N02
0.313,1.563 0.771,1.76 0.458,0.198 10 false GND

Waveform "Control panel LIN communication":

Item Content
Terminal No.
·

H62-7 (LIN1) - H62-17 (GND)

·

H64-20 (RLIN) - H62-17 (GND)


Tool Setting 2 V/DIV., 20 ms./DIV.
Condition Ignition switch ON


c.
E202803N05
0.333,1.469 0.75,1.646 0.417,0.177 10 GND

Waveform "Servo LIN communication":

Item Content
Terminal No.
·

z19-3 (BUS) - z19-2 (BUS G)

·

H64-7 (RBUS) - H64-3 (RBUG)


Tool Setting 2 V/DIV., 2 ms./DIV.
Condition Ignition switch ON



CHECK AIR CONDITIONING CONTROL ASSEMBLY (w/o Toyota Multi Operation Touch System)


E432739E01
3.344,0.365 3.771,0.615 0.427,0.25 3.438,0.406 3.896,0.604 0.458,0.198 10 false H27

HINT:

Check from the rear of the connector while it is connected to the air conditioning control assembly.


Terminal No.
(Symbol)
Terminal Description Condition Specified Condition
H27-1 (ILL+) - Body ground Illumination signal Taillight off Below 1 V
Taillight on 11 to 14 V
H27-5 (ILL-) - Body ground Illumination signal Always Below 1 V
H27-6 (IG+) - H27-10 (GND) Power source (IG) Ignition switch off Below 1 V
Ignition switch ON 11 to 14 V
H27-8 (LIN1) - Body ground LIN communication signal Ignition switch ON Pulse generation
(See waveform)
H27-10 (GND) - Body ground Ground for air conditioning control assembly Always Below 1 V

a.
E202803N05
0.333,1.469 0.75,1.646 0.417,0.177 10 GND

Waveform:

Item Content
Terminal No. H27-8 (LIN1) - Body ground
Tool Setting 2 V/DIV., 20 ms./DIV.
Condition Ignition switch ON



CHECK AIR CONDITIONING CONTROL ASSEMBLY (w/ Toyota Multi Operation Touch System)


E432739E01
3.344,0.365 3.771,0.615 0.427,0.25 3.438,0.406 3.896,0.604 0.458,0.198 10 false H27

HINT:

Check from the rear of the connector while it is connected to the air conditioning control assembly.


Terminal No.
(Symbol)
Terminal Description Condition Specified Condition
H27-3 (LIN1) - Body ground LIN communication signal Ignition switch ON Pulse generation
(See waveform)
H27-4 (IG+) - H27-8 (E) Power source (IG) Ignition switch off Below 1 V
Ignition switch ON 11 to 14 V
H27-5 (ILL+) - Body ground Illumination signal Taillight off Below 1 V
Taillight on 11 to 14 V
H27-8 (E) - Body ground Ground for air conditioning control assembly Always Below 1 V
H27-10 (ILL-) - Body ground Illumination signal Always Below 1 V

a.
E202803N05
0.333,1.469 0.75,1.646 0.417,0.177 10 GND

Waveform:

Item Content
Terminal No. H27-3 (LIN1) - Body ground
Tool Setting 2 V/DIV., 20 ms./DIV.
Condition Ignition switch ON



CHECK NO. 2 AIR CONDITIONING CONTROL ASSEMBLY


E432740E01
3.333,0.625 3.729,0.875 0.396,0.25 3.458,0.667 3.771,0.865 0.313,0.198 10 false T2

HINT:

Check from the rear of the connector while it is connected to the air conditioning control assembly.


Terminal No.
(Symbol)
Terminal Description Condition Specified Condition
T2-6 (ILL-) - Body ground Illumination signal Always Below 1 V
T2-7 (E) - Body ground Ground for No. 2 air conditioning control assembly Always Below 1 V
T2-8 (RLIN) - Body ground LIN communication signal Ignition switch ON Pulse generation
(See waveform)
T2-9 (IG) - T2-7 (E) Power source (IG) Ignition switch off Below 1 V
Ignition switch ON 11 to 14 V
T2-10 (ILL+) - Body ground Illumination signal Taillight off Below 1 V
Taillight on 11 to 14 V

a.
E202803N05
0.333,1.469 0.75,1.646 0.417,0.177 10 GND

Waveform:

Item Content
Terminal No. T2-8 (RLIN) - Body ground
Tool Setting 2 V/DIV., 20 ms./DIV.
Condition Ignition switch ON




MAIN BODY ECU (MULTIPLEX NETWORK BODY ECU)


for WIPER AND WASHER SYSTEM: Click hereVehicle Exterior>WIPER / WASHER>WIPER AND WASHER SYSTEM>TERMINALS OF ECU

for LIGHTING SYSTEM: Click hereVehicle Exterior>LIGHTING (EXT)>LIGHTING SYSTEM>TERMINALS OF ECU