CHECK AIR CONDITIONING AMPLIFIER ASSEMBLY
Check from the rear of the connector while it is connected to the air conditioning amplifier assembly.
| Terminal No.
(Symbol) |
Terminal Description | Condition | Specified Condition |
|---|---|---|---|
| z19-2 (BUS G) - Body ground | Ground for BUS IC | Always | Below 1 V |
| z19-3 (BUS) - z19-2 (BUS G) | BUS IC control signal | Ignition switch ON | Pulse generation
(See waveform "Servo LIN communication") |
| z19-4 (B BUS) - z19-2 (BUS G) | Power supply for BUS IC | Ignition switch off | 11 to 14 V |
| z19-5 (SG) - Body ground | Ground for evaporator temp. sensor (No. 1 cooler thermistor) | Always | Below 1 V |
| z19-6 (TE) - z19-5 (SG) | Evaporator temp. sensor (No. 1 cooler thermistor) signal | ·
Ignition switch ON ·
Evaporator temperature: 0°C (32°F) |
1.7 to 2.1 V |
·
Ignition switch ON ·
Evaporator temperature: 15°C (59°F) |
0.9 to 1.3 V |
| Terminal No.
(Symbol) |
Terminal Description | Condition | Specified Condition |
|---|---|---|---|
| H62-2 (CANH) - H62-1 (CANL) | CAN communication system | CAN communication is performed | Pulse generation |
| H62-5 (B) - H62-17 (GND) | Power source (Back-up) | Ignition switch off | 11 to 14 V |
| H62-6 (IG+) - H62-17 (GND) | Power source (IG) | Ignition switch ON | 11 to 14 V |
| Ignition switch off | Below 1 V | ||
| H62-7 (LIN1) - H62-17 (GND) | LIN communication signal | Ignition switch ON | Pulse generation
(See waveform "Control panel LIN communication") |
| H62-17 (GND) - Body ground | Ground for main power supply | Always | Below 1 V |
| H62-21 (BLW) - H62-17 (GND) | Blower motor speed control signal | ·
Ignition switch ON ·
Blower switch: LO |
Pulse generation
(See waveform "Blower") |
| Terminal No.
(Symbol) |
Terminal Description | Condition | Specified Condition |
|---|---|---|---|
| H63-1 (TAM) - H63-15 (SG-4) | Ambient temp. sensor (thermistor assembly) signal | ·
Ignition switch ON ·
Ambient temperature: 25°C (77°F) |
1.05 to 1.45 V |
·
Ignition switch ON ·
Ambient temperature: 40°C (104°F) |
0.64 to 0.87 V | ||
| H63-3 (SG-1) - Body ground | Ground for room temp. sensor (cooler thermistor) | Always | Below 1 V |
| H63-5 (TR) - H63-3 (SG-1) | Room temp. sensor (cooler thermistor) signal | ·
Ignition switch ON ·
Cabin temperature: 25°C (77°F) |
1.05 to 1.45 V |
·
Ignition switch ON ·
Cabin temperature: 40°C (104°F) |
0.64 to 0.87 V | ||
| H63-6 (PRE) - H63-15 (SG-4) | Air conditioner pressure sensor signal | ·
Ignition switch ON (READY) ·
Air conditioning system operating ·
Refrigerant pressure: Abnormal pressure (more than 3025 kPaG (30.8 kgf/cm2, 439 psi)) |
4.61 V or higher |
·
Ignition switch ON (READY) ·
Air conditioning system operating ·
Refrigerant pressure: Abnormal pressure (less than 176 kPaG (1.8 kgf/cm2, 26 psi)) |
Below 0.74 V | ||
·
Ignition switch ON (READY) ·
Air conditioning system operating ·
Refrigerant pressure: Normal pressure (less than 3025 kPaG (30.8 kgf/cm2, 439 psi) and more than 176 kPaG (1.8 kgf/cm2, 26 psi)) |
0.74 to 4.61 V | ||
| H63-11 (S5-3) - H63-15 (SG-4) | Power supply for air conditioner pressure sensor | Ignition switch ON | 4.75 to 5.25 V |
| Ignition switch off | Below 1 V | ||
| H63-15 (SG-4) - Body ground | Ground for air conditioner pressure sensor | Always | Below 1 V |
| Terminal No.
(Symbol) |
Terminal Description | Condition | Specified Condition |
|---|---|---|---|
| H64-1 (+B2) - H62-17 (GND) | Power source (Back-up) | Ignition switch off | 11 to 14 V |
| H64-2 (RBBU) - H64-3 (RBUG) | Power supply for BUS IC | Ignition switch off | 11 to 14 V |
| H64-3 (RBUG) - Body ground | Ground for BUS IC | Always | Below 1 V |
| H64-4 (GND2) - Body ground | Ground for main power supply | Always | Below 1 V |
| H64-7 (RBUS) - H64-3 (RBUG) | BUS IC control signal | Ignition switch ON | Pulse generation
(See waveform "Servo LIN communication") |
| H64-10 (SBLW) - H62-17 (GND) | Blower motor speed control signal | ·
Ignition switch ON ·
Blower switch: LO |
Pulse generation
(See waveform "Blower") |
| H64-20 (RLIN) - H62-17 (GND) | LIN communication signal | Ignition switch ON | Pulse generation
(See waveform "Control panel LIN communication") |
| Terminal No.
(Symbol) |
Terminal Description | Condition | Specified Condition |
|---|---|---|---|
| H65-8 (TR) - H65-14 (SG-8) | No. 2 room temp. sensor (cooler thermistor) signal | ·
Ignition switch ON ·
Cabin temperature: 25°C (77°F) |
1.05 to 1.45 V |
·
Ignition switch ON ·
Cabin temperature: 40°C (104°F) |
0.64 to 0.87 V | ||
| H65-11 (TEC) - H65-15 (SG-9) | Rear evaporator temp. sensor (No. 2 air conditioning harness assembly) signal | ·
Ignition switch ON ·
Evaporator temperature: 0°C (32°F) |
1.7 to 2.1 V |
·
Ignition switch ON ·
Evaporator temperature: 15°C (59°F) |
0.9 to 1.3 V | ||
| H65-14 (SG-8) - Body ground | Ground for No. 2 room temp. sensor (cooler thermistor) | Always | Below 1 V |
| H65-15 (SG-9) - Body ground | Ground for Rear evaporator temp. sensor (No. 2 air conditioning harness assembly) | Always | Below 1 V |
Waveform "Blower":
| Item | Content |
|---|---|
| Terminal No. | ·
H62-21 (BLW) - H62-17 (GND) ·
H64-10 (SBLW) - H62-17 (GND) |
| Tool Setting | 2 V/DIV., 1 ms./DIV. |
| Condition | ·
Ignition switch ON ·
Blower switch: LO |
Waveform "Control panel LIN communication":
| Item | Content |
|---|---|
| Terminal No. | ·
H62-7 (LIN1) - H62-17 (GND) ·
H64-20 (RLIN) - H62-17 (GND) |
| Tool Setting | 2 V/DIV., 20 ms./DIV. |
| Condition | Ignition switch ON |
Waveform "Servo LIN communication":
| Item | Content |
|---|---|
| Terminal No. | ·
z19-3 (BUS) - z19-2 (BUS G) ·
H64-7 (RBUS) - H64-3 (RBUG) |
| Tool Setting | 2 V/DIV., 2 ms./DIV. |
| Condition | Ignition switch ON |
CHECK AIR CONDITIONING CONTROL ASSEMBLY (w/o Toyota Multi Operation Touch System)
Check from the rear of the connector while it is connected to the air conditioning control assembly.
| Terminal No.
(Symbol) |
Terminal Description | Condition | Specified Condition |
|---|---|---|---|
| H27-1 (ILL+) - Body ground | Illumination signal | Taillight off | Below 1 V |
| Taillight on | 11 to 14 V | ||
| H27-5 (ILL-) - Body ground | Illumination signal | Always | Below 1 V |
| H27-6 (IG+) - H27-10 (GND) | Power source (IG) | Ignition switch off | Below 1 V |
| Ignition switch ON | 11 to 14 V | ||
| H27-8 (LIN1) - Body ground | LIN communication signal | Ignition switch ON | Pulse generation
(See waveform) |
| H27-10 (GND) - Body ground | Ground for air conditioning control assembly | Always | Below 1 V |
Waveform:
| Item | Content |
|---|---|
| Terminal No. | H27-8 (LIN1) - Body ground |
| Tool Setting | 2 V/DIV., 20 ms./DIV. |
| Condition | Ignition switch ON |
CHECK AIR CONDITIONING CONTROL ASSEMBLY (w/ Toyota Multi Operation Touch System)
Check from the rear of the connector while it is connected to the air conditioning control assembly.
| Terminal No.
(Symbol) |
Terminal Description | Condition | Specified Condition |
|---|---|---|---|
| H27-3 (LIN1) - Body ground | LIN communication signal | Ignition switch ON | Pulse generation
(See waveform) |
| H27-4 (IG+) - H27-8 (E) | Power source (IG) | Ignition switch off | Below 1 V |
| Ignition switch ON | 11 to 14 V | ||
| H27-5 (ILL+) - Body ground | Illumination signal | Taillight off | Below 1 V |
| Taillight on | 11 to 14 V | ||
| H27-8 (E) - Body ground | Ground for air conditioning control assembly | Always | Below 1 V |
| H27-10 (ILL-) - Body ground | Illumination signal | Always | Below 1 V |
Waveform:
| Item | Content |
|---|---|
| Terminal No. | H27-3 (LIN1) - Body ground |
| Tool Setting | 2 V/DIV., 20 ms./DIV. |
| Condition | Ignition switch ON |
CHECK NO. 2 AIR CONDITIONING CONTROL ASSEMBLY
Check from the rear of the connector while it is connected to the air conditioning control assembly.
| Terminal No.
(Symbol) |
Terminal Description | Condition | Specified Condition |
|---|---|---|---|
| T2-6 (ILL-) - Body ground | Illumination signal | Always | Below 1 V |
| T2-7 (E) - Body ground | Ground for No. 2 air conditioning control assembly | Always | Below 1 V |
| T2-8 (RLIN) - Body ground | LIN communication signal | Ignition switch ON | Pulse generation
(See waveform) |
| T2-9 (IG) - T2-7 (E) | Power source (IG) | Ignition switch off | Below 1 V |
| Ignition switch ON | 11 to 14 V | ||
| T2-10 (ILL+) - Body ground | Illumination signal | Taillight off | Below 1 V |
| Taillight on | 11 to 14 V |
Waveform:
| Item | Content |
|---|---|
| Terminal No. | T2-8 (RLIN) - Body ground |
| Tool Setting | 2 V/DIV., 20 ms./DIV. |
| Condition | Ignition switch ON |
HYBRID VEHICLE CONTROL ECU
for 2WD:Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM (for 2WD)>TERMINALS OF ECU
for AWD:Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM (for 4WD/AWD)>TERMINALS OF ECU
MAIN BODY ECU (MULTIPLEX NETWORK BODY ECU)
for WIPER AND WASHER SYSTEM: Click hereVehicle Exterior>WIPER / WASHER>WIPER AND WASHER SYSTEM>TERMINALS OF ECU
for LIGHTING SYSTEM: Click hereVehicle Exterior>LIGHTING (EXT)>LIGHTING SYSTEM>TERMINALS OF ECU