CAN COMMUNICATION SYSTEM (w/ VSC) > Check CAN Bus Line for Short to +B |
| Symptom | Trouble Area |
| The resistance between terminals 6 (CANH) and 16 (BAT) or terminals 14 (CANL) and 16 (BAT) of the DLC3 is below 1 Ω. |
|

| 1.DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL |
Disconnect the cable from the negative (-) battery terminal before measuring the resistances of the main wire and the branch wire.
| NEXT | |
| 2.CHECK FOR SHORT TO +B IN CAN BUS WIRE (DLC3 BRANCH WIRE) |
![]() |
Disconnect the J51 No. 3 junction connector connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Measured Resistance | Proceed to |
| D3-6 (CANH) - D3-16 (BAT) | Ignition switch off | 1 Ω or higher | OK |
| D3-14 (CANL) - D3-16 (BAT) | |||
| D3-6 (CANH) - D3-16 (BAT) | Ignition switch off | Below 1 Ω | NG |
| D3-14 (CANL) - D3-16 (BAT) |
|
| ||||
| OK | |
| 3.CONNECT CONNECTOR |
Reconnect the J51 No. 3 junction connector connector.
| NEXT | |
| 4.CHECK FOR SHORT TO +B IN CAN BUS WIRE (NO. 1 JUNCTION CONNECTOR SIDE) |
![]() |
Disconnect the J57 No. 1 junction connector connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Measured Resistance | Proceed to |
| D3-6 (CANH) - D3-16 (BAT) | Ignition switch off | 1 Ω or higher | OK |
| D3-14 (CANL) - D3-16 (BAT) | |||
| D3-6 (CANH) - D3-16 (BAT) | Ignition switch off | Below 1 Ω | NG |
| D3-14 (CANL) - D3-16 (BAT) |
|
| ||||
| OK | |
| 5.CHECK FOR SHORT TO +B IN CAN BUS WIRE (NO. 1 JUNCTION CONNECTOR - SKID CONTROL ECU) |
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Measured Resistance | Proceed to |
| J57-13 (CANH) - D3-16 (BAT) | Ignition switch off | 1 Ω or higher | OK |
| J57-7 (CANL) - D3-16 (BAT) | |||
| J57-13 (CANH) - D3-16 (BAT) | Ignition switch off | Below 1 Ω | NG |
| J57-7 (CANL) - D3-16 (BAT) |
|
| ||||
| OK | |
| 6.CHECK FOR SHORT TO +B IN CAN BUS WIRE (NO. 1 JUNCTION CONNECTOR - ECM) |
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Measured Resistance | Proceed to |
| J57-12 (CANH) - D3-16 (BAT) | Ignition switch off | 1 Ω or higher | OK |
| J57-6 (CANL) - D3-16 (BAT) | |||
| J57-12 (CANH) - D3-16 (BAT) | Ignition switch off | Below 1 Ω | NG |
| J57-6 (CANL) - D3-16 (BAT) |
|
| ||||
| OK | ||
| ||
| 7.CHECK FOR SHORT TO +B IN CAN BUS WIRE (SKID CONTROL ECU) |
![]() |
Disconnect the S25 skid control ECU connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Measured Resistance | Proceed to |
| J57-13 (CANH) - D3-16 (BAT) | Ignition switch off | 1 Ω or higher | OK |
| J57-7 (CANL) - D3-16 (BAT) | |||
| J57-13 (CANH) - D3-16 (BAT) | Ignition switch off | Below 1 Ω | NG |
| J57-7 (CANL) - D3-16 (BAT) |
|
| ||||
| OK | ||
| ||
| 8.CHECK FOR SHORT TO +B IN CAN BUS WIRE (ECM) |
![]() |
Disconnect the E5*1 or E13*2 ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Measured Resistance | Result | Proceed to |
| J57-12 (CANH) - D3-16 (BAT) | Ignition switch off | 1 Ω or higher | OK (for 1KD-FTV) | A |
| OK (for 2KD-FTV) | B | |||
| J57-6 (CANL) - D3-16 (BAT) | OK (for 1GR-FE) | C | ||
| J57-12 (CANH) - D3-16 (BAT) | Ignition switch off | Below 1 Ω | NG | D |
| J57-6 (CANL) - D3-16 (BAT) |
|
| ||||
|
| ||||
|
| ||||
| A | ||
| ||
| 9.CHECK FOR SHORT TO +B IN CAN BUS WIRE (NO. 2 JUNCTION CONNECTOR - NO. 1 JUNCTION CONNECTOR) |
![]() |
Disconnect the J56 No. 2 junction connector connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Measured Resistance | Proceed to |
| J56-1 (CANH) - D3-16 (BAT) | Ignition switch off | 1 Ω or higher | OK |
| J56-2 (CANL) - D3-16 (BAT) | |||
| J56-1 (CANH) - D3-16 (BAT) | Ignition switch off | Below 1 Ω | NG |
| J56-2 (CANL) - D3-16 (BAT) |
|
| ||||
| OK | |
| 10.CONNECT CONNECTOR |
Reconnect the J57 No. 1 junction connector connector.
| NEXT | |
| 11.CHECK FOR SHORT TO +B IN CAN BUS WIRE (NO. 2 JUNCTION CONNECTOR SIDE) |
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Measured Resistance | Proceed to |
| D3-6 (CANH) - D3-16 (BAT) | Ignition switch off | 1 Ω or higher | OK |
| D3-14 (CANL) - D3-16 (BAT) | |||
| D3-6 (CANH) - D3-16 (BAT) | Ignition switch off | Below 1 Ω | NG |
| D3-14 (CANL) - D3-16 (BAT) |
|
| ||||
| OK | |
| 12.CHECK FOR SHORT TO +B IN CAN BUS WIRE (NO. 2 JUNCTION CONNECTOR - YAW RATE SENSOR) |
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Measured Resistance | Proceed to |
| J56-4 (CANH) - D3-16 (BAT) | Ignition switch off | 1 Ω or higher | OK |
| J56-6 (CANL) - D3-16 (BAT) | |||
| J56-4 (CANH) - D3-16 (BAT) | Ignition switch off | Below 1 Ω | NG |
| J56-6 (CANL) - D3-16 (BAT) |
|
| ||||
| OK | ||
| ||
| 13.CHECK FOR SHORT TO +B IN CAN BUS WIRE (YAW RATE SENSOR) |
![]() |
Disconnect the Y1 yaw rate sensor connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Measured Resistance | Proceed to |
| J56-4 (CANH) - D3-16 (BAT) | Ignition switch off | 1 Ω or higher | OK |
| J56-6 (CANL) - D3-16 (BAT) | |||
| J56-4 (CANH) - D3-16 (BAT) | Ignition switch off | Below 1 Ω | NG |
| J56-6 (CANL) - D3-16 (BAT) |
|
| ||||
| OK | ||
| ||
| 14.CHECK FOR SHORT TO +B IN CAN BUS WIRE (NO. 3 JUNCTION CONNECTOR - NO. 2 JUNCTION CONNECTOR) |
![]() |
Disconnect the J52 No. 3 junction connector connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Measured Resistance | Proceed to |
| J52-2 (CANH) - D3-16 (BAT) | Ignition switch off | 1 Ω or higher | OK |
| J52-1 (CANL) - D3-16 (BAT) | |||
| J52-2 (CANH) - D3-16 (BAT) | Ignition switch off | Below 1 Ω | NG |
| J52-1 (CANL) - D3-16 (BAT) |
|
| ||||
| OK | |
| 15.CONNECT CONNECTOR |
Reconnect the J56 No. 2 junction connector connector.
Reconnect the J52 No. 3 junction connector connector.
| NEXT | |
| 16.CHECK FOR SHORT TO +B IN CAN BUS WIRE (NO. 3 JUNCTION CONNECTOR - STEERING ANGLE SENSOR) |
![]() |
Disconnect the J53 No. 3 junction connector connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Measured Resistance | Proceed to |
| J53-2 (CANH) - D3-16 (BAT) | Ignition switch off | 1 Ω or higher | OK |
| J53-1 (CANL) - D3-16 (BAT) | |||
| J53-2 (CANH) - D3-16 (BAT) | Ignition switch off | Below 1 Ω | NG |
| J53-1 (CANL) - D3-16 (BAT) |
|
| ||||
| OK | ||
| ||
| 17.CHECK FOR SHORT TO +B IN CAN BUS WIRE (STEERING ANGLE SENSOR) |
![]() |
Disconnect the S23 steering angle sensor connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Measured Resistance | Proceed to |
| J53-2 (CANH) - D3-16 (BAT) | Ignition switch off | 1 Ω or higher | OK |
| J53-1 (CANL) - D3-16 (BAT) | |||
| J53-2 (CANH) - D3-16 (BAT) | Ignition switch off | Below 1 Ω | NG |
| J53-1 (CANL) - D3-16 (BAT) |
|
| ||||
| OK | ||
| ||