Open in CAN Main Bus Line
Circuit diagnosis · Vehicles built from Aug 2014
Versions by build date: Jun 2011 – Jul 2012 Aug 2012 – Jul 2013 Aug 2013 – Jul 2014 from Aug 2014
DESCRIPTION
There may be an open circuit in the CAN main wire and/or the DLC3 branch wire when the resistance between terminals 6 (CANH) and 14 (CANL) of the DLC3 is 70 Ω or higher.| Symptom |
Trouble Area |
| Resistance between terminals 6 (CANH) and 14 (CANL) of DLC3 is 70 Ω or higher. |
|
WIRING DIAGRAM


INSPECTION PROCEDURE
- HINT:
- Operating the ignition switch, any switches or any doors triggers related ECU and sensor communication with the CAN, which causes resistance variation.
| 1. DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL |
Disconnect the cable from the negative (-) battery terminal before measuring the resistances of the main wire and the branch wire.
- CAUTION:
- Wait at least 90 seconds after disconnecting the cable from the negative (-) battery terminal to disable the SRS system.
- NOTICE:
- When disconnecting the cable from the negative (-) battery terminal, some systems need to be initialized after the cable is reconnected (Click here).
| NEXT | |
| 2. CHECK FOR OPEN IN CAN BUS WIRE (NO. 3 JUNCTION CONNECTOR - DLC3) |
Disconnect the J49 No. 3 junction connector.

Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Switch Condition
Specified Condition
J49-2 (CANH) - D1-6 (CANH)
Ignition switch off
Below 1 Ω
J49-1 (CANL) - D1-14 (CANL)
Ignition switch off
Below 1 Ω
|
|
||||
| OK | |
| 3. CONNECT CONNECTOR |
Reconnect the J49 No. 3 junction connector.
| NEXT | |
| 4. CHECK FOR OPEN IN CAN BUS MAIN WIRE (NO. 1 JUNCTION CONNECTOR - NO. 3 JUNCTION CONNECTOR) |
Disconnect the J67 No. 1 junction connector.

Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Switch Condition
Specified Condition
J67-1 (CANH) - J67-7 (CANL)
Ignition switch off
108 to 132 Ω
|
|
||||
| OK | |
| 5. CHECK FOR OPEN IN CAN BUS MAIN WIRE (NO. 1 JUNCTION CONNECTOR - ECM) |
Measure the resistance according to the value(s) in the table below.

- Standard Resistance:
Tester Connection
Switch Condition
Specified Condition
J67-2 (CANH) - J67-8 (CANL)
Ignition switch off
108 to 132 Ω
|
|
||||
| OK | ||
| ||
| 6. CONNECT CONNECTOR |
Reconnect the J67 No. 1 junction connector.
| NEXT | |
| 7. CHECK FOR OPEN IN CAN BUS MAIN WIRE (NO. 2 JUNCTION CONNECTOR - NO. 3 JUNCTION CONNECTOR) |
Disconnect the J59 No. 2 junction connector.

Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Switch Condition
Specified Condition
J59-6 (CANH) - J59-17 (CANL)
Ignition switch off
108 to 132 Ω
|
|
||||
| OK | |
| 8. CHECK FOR OPEN IN CAN BUS MAIN WIRE (NO. 2 JUNCTION CONNECTOR - NO. 1 JUNCTION CONNECTOR) |
Measure the resistance according to the value(s) in the table below.

- Standard Resistance:
Tester Connection
Switch Condition
Specified Condition
J59-5 (CANH) - J59-16 (CANL)
Ignition switch off
108 to 132 Ω
|
|
||||
| OK | ||
| ||
| 9. CONNECT CONNECTOR |
Reconnect the J59 No. 2 junction connector.
| NEXT | |
| 10. CHECK FOR OPEN IN CAN BUS MAIN WIRE (NO. 3 JUNCTION CONNECTOR - NO. 2 JUNCTION CONNECTOR) |
Disconnect the J50 No. 3 junction connector.

Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Switch Condition
Specified Condition
J50-2 (CANH) - J50-1 (CANL)
Ignition switch off
108 to 132 Ω
|
|
||||
| OK | ||
| ||
| 11. CONNECT CONNECTOR |
Reconnect the J67 No. 1 junction connector.
| NEXT | |
| 12. CHECK FOR OPEN IN CAN BUS MAIN WIRE (ECM - NO. 1 JUNCTION CONNECTOR) |
for 1KD-FTV, 2KD-FTV (w/ DPF):
Disconnect the E30 ECM connector.

Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Switch Condition
Specified Condition
E30-35 (CANH) - E30-36 (CANL)
Ignition switch off
108 to 132 Ω
for 1KD-FTV, 2KD-FTV (w/o DPF):
Disconnect the E6 ECM connector.

Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Switch Condition
Specified Condition
E6-24 (CANH) - E6-23 (CANL)
Ignition switch off
108 to 132 Ω
for 1GR-FE:
Disconnect the E13 ECM connector.

Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Switch Condition
Specified Condition
E13-33 (CANH) - E13-34 (CANL)
Ignition switch off
108 to 132 Ω
| Result |
Proceed to |
| OK (for 1KD-FTV) |
A |
| OK (for 2KD-FTV) |
B |
| OK (for 1GR-FE) |
C |
| NG |
D |
|
|
||||
|
|
||||
|
|
||||
| A | ||
| ||