2014 Hilux · Service Manual COMMUNICATION SYSTEM

Open in CAN Main Bus Line

Circuit diagnosis · Vehicles built Jun 2011 – Jul 2012

Versions by build date: Jun 2011 – Jul 2012 Aug 2012 – Jul 2013 Aug 2013 – Jul 2014 from Aug 2014

DESCRIPTION

There may be an open circuit in the CAN main wire and/or the DLC3 branch wire when the resistance between terminals 6 (CANH) and 14 (CANL) of the DLC3 is 70 Ω or higher.
Symptom
Trouble Area
Resistance between terminals 6 (CANH) and 14 (CANL) of DLC3 is 70 Ω or higher.
  1. CAN main wire and connector
  2. No. 1 junction connector
  3. No. 2 junction connector
  4. No. 3 junction connector
  5. ECM
  6. DLC3 branch wire or connector

WIRING DIAGRAM

C190674E06

INSPECTION PROCEDURE

HINT:
Operating the ignition switch, any switches or any doors triggers related ECU and sensor communication with the CAN, which causes resistance variation.


1. DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL
  1. Disconnect the cable from the negative (-) battery terminal before measuring the resistances of the main wire and the branch wire.

    CAUTION:
    Wait at least 90 seconds after disconnecting the cable from the negative (-) battery terminal to disable the SRS system.

    NOTICE:
    When disconnecting the cable from the negative (-) battery terminal, some systems need to be initialized after the cable is reconnected (Click here).


NEXT


2. CHECK FOR OPEN IN CAN BUS WIRE (NO. 3 JUNCTION CONNECTOR - DLC3)

  1. C245024E01
    Disconnect the J49 No. 3 junction connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    J49-2 (CANH) - D1-6 (CANH)
    Ignition switch off
    Below 1 Ω
    J49-1 (CANL) - D1-14 (CANL)
    Ignition switch off
    Below 1 Ω



NG
REPAIR OR REPLACE CAN BRANCH WIRE CONNECTED TO DLC3 (CANH, CANL)
OK


3. CONNECT CONNECTOR
  1. Reconnect the J49 No. 3 junction connector.


NEXT


4. CHECK FOR OPEN IN CAN BUS MAIN WIRE (NO. 1 JUNCTION CONNECTOR - NO. 3 JUNCTION CONNECTOR)

  1. C190785E05
    Disconnect the J54 No. 1 junction connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    J54-4 (CANH) - J54-1 (CANL)
    Ignition switch off
    108 to 132 Ω



NG
Go to step 6
OK


5. CHECK FOR OPEN IN CAN BUS MAIN WIRE (NO. 1 JUNCTION CONNECTOR - ECM)

  1. C190785E06
    Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    J54-12 (CANH) - J54-6 (CANL)
    Ignition switch off
    108 to 132 Ω



NG
Go to step 11
OK

REPLACE NO. 1 JUNCTION CONNECTOR

6. CONNECT CONNECTOR
  1. Reconnect the J54 No. 1 junction connector.


NEXT


7. CHECK FOR OPEN IN CAN BUS MAIN WIRE (NO. 2 JUNCTION CONNECTOR - NO. 3 JUNCTION CONNECTOR)

  1. C245025E01
    Disconnect the J59 No. 2 junction connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    J59-6 (CANH) - J59-17 (CANL)
    Ignition switch off
    108 to 132 Ω



NG
Go to step 9
OK


8. CHECK FOR OPEN IN CAN BUS MAIN WIRE (NO. 2 JUNCTION CONNECTOR - NO. 1 JUNCTION CONNECTOR)

  1. C245025E02
    Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    J59-5 (CANH) - J59-16 (CANL)
    Ignition switch off
    108 to 132 Ω



NG
REPAIR OR REPLACE CAN MAIN WIRE OR CONNECTOR (NO. 2 JUNCTION CONNECTOR - NO. 1 JUNCTION CONNECTOR)
OK

REPLACE NO. 2 JUNCTION CONNECTOR

9. CONNECT CONNECTOR
  1. Reconnect the J59 No. 2 junction connector.


NEXT


10. CHECK FOR OPEN IN CAN BUS MAIN WIRE (NO. 3 JUNCTION CONNECTOR - NO. 2 JUNCTION CONNECTOR)

  1. C190789E05
    Disconnect the J50 No. 3 junction connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    J50-2 (CANH) - J50-1 (CANL)
    Ignition switch off
    108 to 132 Ω



NG
REPAIR OR REPLACE CAN MAIN WIRE OR CONNECTOR (NO. 3 JUNCTION CONNECTOR - NO. 2 JUNCTION CONNECTOR)
OK

REPLACE NO. 3 JUNCTION CONNECTOR

11. CONNECT CONNECTOR
  1. Reconnect the J54 No. 1 junction connector.


NEXT


12. CHECK FOR OPEN IN CAN BUS MAIN WIRE (ECM - NO. 1 JUNCTION CONNECTOR)

  1. for 1KD-FTV, 2KD-FTV (w/ DPF):

    1. C245028E01
      Disconnect the E30 ECM connector.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance:
      Tester Connection
      Switch Condition
      Specified Condition
      E30-35 (CANH) - E30-36 (CANL)
      Ignition switch off
      108 to 132 Ω

  1. for 1KD-FTV, 2KD-FTV (w/o DPF):

    1. C190783E03
      Disconnect the E6 ECM connector.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance:
      Tester Connection
      Switch Condition
      Specified Condition
      E6-24 (CANH) - E6-23 (CANL)
      Ignition switch off
      108 to 132 Ω

  1. for 1GR-FE:

    1. C245027E01
      Disconnect the E13 ECM connector.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance:
      Tester Connection
      Switch Condition
      Specified Condition
      E13-33 (CANH) - E13-34 (CANL)
      Ignition switch off
      108 to 132 Ω

Result 
Result
Proceed to
OK (for 1KD-FTV)
A
OK (for 2KD-FTV)
B
OK (for 1GR-FE)
C
NG
D


B
REPLACE ECM (Click here)

C
REPLACE ECM (Click here)

D
REPAIR OR REPLACE CAN MAIN WIRE CONNECTED TO ECM (ECM - NO. 1 JUNCTION CONNECTOR)
A

REPLACE ECM (Click here)


← ECM Communication Stop Mode (from Aug 2013)Open in CAN Main Bus Line (Aug 2012 – Jul 2013) →