Home › Engine / Hybrid System › 1KD-FTV ENGINE CONTROL › ECD SYSTEM(w/ EGR Cooler) › 2011.10–2012.04
RM1840EF _51 Engine / Hybrid System _009570 1KD-FTV ENGINE CONTROL _0052102 ECD SYSTEM(w/ EGR Cooler) C

1KD-FTV ENGINE CONTROL  ECD SYSTEM(w/ EGR Cooler)  P0489  Exhaust Gas Recirculation Control Circuit Low  P0490  Exhaust Gas Recirculation Control Circuit High  


DESCRIPTION

The EGR system recirculates exhaust gases in a way that suits every driving condition. The recirculated gas mixes with intake air. Therefore, the EGR system can slow combustion speed and keep the combustion temperature down. This helps reduce NOx emission.

In order to increase EGR circulation efficiency, the ECM adjusts the lift amount of the EGR valve and the throttle valve angle.

DTC No. Detection Item DTC Detection Condition Trouble Area MIL Memory
P0489 Exhaust Gas Recirculation Control Circuit Low Open or short in electric vacuum regulating valve assembly circuit for 5 seconds or more (1 trip detection logic).
·

Electric vacuum regulating valve assembly

·

Open or short in electric vacuum regulating valve assembly circuit

·

ECM


Comes on DTC stored
P0490 Exhaust Gas Recirculation Control Circuit High Open or short in electric vacuum regulating valve assembly circuit for 5 seconds or more (1 trip detection logic).
·

Electric vacuum regulating valve assembly

·

Open or short in electric vacuum regulating valve assembly circuit

·

ECM


Comes on DTC stored

Related Data List
DTC No. Data List
P0489
·

Actual EGR Valve Pos.

·

Target EGR Position


P0490

CONFIRMATION DRIVING PATTERN

P0489, P0490
DTC Detection Drive Pattern 5 seconds after engine is started

CAUTION / NOTICE / HINT

NOTICE:
·

Inspect the fuses of circuits related to this system before performing the following inspection procedure.



PROCEDURE

1.INSPECT ELECTRIC VACUUM REGULATING VALVE ASSEMBLY
a.

Inspect the electric vacuum regulating valve assembly.

Click hereEngine / Hybrid System>1KD-FTV EMISSION CONTROL>VACUUM REGULATING VALVE>INSPECTION


Result:
Proceed to
OK
NG



OK

2.CHECK TERMINAL VOLTAGE (POWER SOURCE)

NG

5.REPLACE ELECTRIC VACUUM REGULATING VALVE ASSEMBLY
2.CHECK TERMINAL VOLTAGE (POWER SOURCE)
a.
A255071
0.552,0.927 0.958,1.167 0.406,0.24 0.219,0.083 0.573,0.25 0.354,0.167 10 false *a 0.656,0.958 0.875,1.125 0.219,0.167 10 false C8
*a Front view of wire harness connector
(to Electric Vacuum Regulating Valve Assembly)


Disconnect the electric vacuum regulating valve assembly connector.


b.

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Switch Condition Specified Condition
C8-1 - Body ground Ignition switch ON 11 to 14 V



c.

Reconnect the electric vacuum regulating valve assembly connector.


Result:
Proceed to
OK
NG



OK

3.CHECK HARNESS AND CONNECTOR (ELECTRIC VACUUM REGULATING VALVE ASSEMBLY - ECM)

NG

6.REPAIR OR REPLACE HARNESS OR CONNECTOR
3.CHECK HARNESS AND CONNECTOR (ELECTRIC VACUUM REGULATING VALVE ASSEMBLY - ECM)
a.

Disconnect the electric vacuum regulating valve assembly connector.


b.

Disconnect the ECM connector.


c.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
C8-2 - C23-9 (EGR) Always Below 1 Ω
C8-2 or C23-9 (EGR) - Body ground Always 10 kΩ or higher



d.

Reconnect the electric vacuum regulating valve assembly connector.


e.

Reconnect the ECM connector.


Result:
Proceed to
OK
NG



OK

4.REPLACE ECM

NG

6.REPAIR OR REPLACE HARNESS OR CONNECTOR
4.REPLACE ECM

Result:
Proceed to
NEXT



NEXT

7.CONFIRM WHETHER MALFUNCTION HAS BEEN SUCCESSFULLY REPAIRED
5.REPLACE ELECTRIC VACUUM REGULATING VALVE ASSEMBLY
a.

Replace the electric vacuum regulating valve assembly.

Click hereEngine / Hybrid System>1KD-FTV EMISSION CONTROL>VACUUM REGULATING VALVE>REMOVAL


Result:
Proceed to
NEXT



NEXT

7.CONFIRM WHETHER MALFUNCTION HAS BEEN SUCCESSFULLY REPAIRED
6.REPAIR OR REPLACE HARNESS OR CONNECTOR
a.

Repair or replace the harness or connector.

HINT:

If the voltage at the electric vacuum regulating valve assembly connector is not 11 to 14 V, repair or replace the harness and connector between the electric vacuum regulating valve assembly and the MAIN relay.



Result:
Proceed to
NEXT



NEXT

7.CONFIRM WHETHER MALFUNCTION HAS BEEN SUCCESSFULLY REPAIRED
7.CONFIRM WHETHER MALFUNCTION HAS BEEN SUCCESSFULLY REPAIRED
a.

Connect the intelligent tester to the DLC3.


b.

Clear the DTCs.

Click hereEngine / Hybrid System>1KD-FTV ENGINE CONTROL>ECD SYSTEM(w/ EGR Cooler)>DTC CHECK / CLEAR

Powertrain > Engine > Clear DTCs
50002 61

c.

Turn the ignition switch off for 30 seconds or more.


d.

Start the engine.


e.

Idle the engine for 5 seconds or more.


f.

Enter the following menus: Powertrain / Engine and ECT / DTC.

Powertrain > Engine > Trouble Codes
50001 61

g.

Confirm that the DTC is not output again.


Result:
Proceed to
NEXT



NEXT

END