Home › Engine / Hybrid System › 1KD-FTV ENGINE CONTROL › ECD SYSTEM(for DPF) › 2012.04–2012.10
RM1840EF _51 Engine / Hybrid System _009570 1KD-FTV ENGINE CONTROL _0052104 ECD SYSTEM(for DPF) C

1KD-FTV ENGINE CONTROL  ECD SYSTEM(for DPF)  P011C  Charge Air Temperature/Intake Air Temperature Correlation (Bank 1)  


DESCRIPTION

Refer to DTC P007C (See page Engine / Hybrid System>1KD-FTV ENGINE CONTROL>ECD SYSTEM(for DPF)>P007C).

Refer to DTC P0112 (See page Engine / Hybrid System>1KD-FTV ENGINE CONTROL>ECD SYSTEM(for DPF)>P0112).

DTC No. Detection Item DTC Detection Condition Trouble Area MIL Memory
P011C Charge Air Temperature/Intake Air Temperature Correlation (Bank 1) After the engine is completely warmed up and then allowed to soak for a long time (10 hours or more), the difference in temperature at the intake air temperature sensor and intake air temperature sensor (turbo) after turbocharger after idling for 3 minutes is 15°C (59°F) or higher.
(2 trip detection logic)
·

Open or short in intake air temperature sensor circuit

·

Open or short in intake air temperature sensor (turbo) circuit

·

Intake air temperature sensor (built into mass air flow meter)

·

Intake air temperature sensor (turbo)

·

ECM

·

Engine off timer (P2610)


Comes on DTC stored

Related Data List
DTC No. Data List
P011C
·

Intake Air

·

Intake Air Temp (Turbo)



CONFIRMATION DRIVING PATTERN

P011C
DTC Detection Drive Pattern After engine completely warmed up, allow engine to soak for long time (10 hours or more).
Start the engine and idle the engine for 3 minutes or more.

CAUTION / NOTICE / HINT

NOTICE:
·

Inspect the fuses of circuits related to this system before performing the following inspection procedure.

·

After replacing the fuel supply pump assembly, the ECM needs initialization (See page Engine / Hybrid System>1KD-FTV ENGINE CONTROL>ECD SYSTEM(for DPF)>INITIALIZATION).

·

After replacing an injector assembly, the ECM needs registration (See page Engine / Hybrid System>1KD-FTV ENGINE CONTROL>ECD SYSTEM(for DPF)>REGISTRATION).



HINT:

Read freeze frame data using the intelligent tester. Freeze frame data records the engine condition when malfunctions are detected. When troubleshooting, freeze frame data can help determine if the vehicle was moving or stationary, if the engine was warmed up or not, and other data from the time the malfunction occurred.


PROCEDURE

1.CHECK OTHER DTC OUTPUT (IN ADDITION TO DTC P011C)
a.

Connect the intelligent tester to the DLC3.


b.

Turn the ignition switch to ON and turn the tester on.


c.

Enter the following menus: Powertrain / Engine and ECT / DTC.

Powertrain > Engine > Trouble Codes
50001 61

d.

Read the DTCs.

Result:
Result Proceed to
P011C is output A
P011C and other DTCs are output B




A

2.READ VALUE USING INTELLIGENT TESTER (ENGINE COOLANT TEMPERATURE)

B

2.READ VALUE USING INTELLIGENT TESTER (ENGINE COOLANT TEMPERATURE)
a.

Allow the engine to soak for 1 to 2 hours.

HINT:
·

It is not necessary to allow the engine to soak if the engine is cold.

·

The engine cools faster if the hood is opened.




b.

Connect the intelligent tester to the DLC3.


c.

Turn the ignition switch to ON and turn the tester on.


d.

Enter the following menus: Powertrain / Engine and ECT / Data List / Coolant temp.

Powertrain > Engine > Data List
Tester Display
Coolant Temp
50003 61 309

e.

Read the value.

OK:

The difference between the displayed value and outside air temperature is below 5°C (9°F).


NOTICE:

If the difference between "Coolant Temp" and the outside air temperature is 5°C (9°F) or higher, the heat from the engine affects the intake air temperature sensor, causing an incorrect value to be displayed. In this case, allow the engine to soak again.



Result:
Proceed to
NEXT



NEXT

3.READ VALUE USING INTELLIGENT TESTER (INTAKE AIR TEMPERATURE)
3.READ VALUE USING INTELLIGENT TESTER (INTAKE AIR TEMPERATURE)
a.

Connect the intelligent tester to the DLC3.


b.

Turn the ignition switch to ON and turn the tester on.


c.

Enter the following menus: Powertrain / Engine and ECT / Data List / Intake Air.

Powertrain > Engine > Data List
Tester Display
Intake Air
50003 61 318

d.

Read the value.

OK:

The difference between the displayed value and outside air temperature is below 15°C (27°F).



Result:
Proceed to
OK
NG



OK

4.READ VALUE USING INTELLIGENT TESTER (INTAKE AIR TEMPERATURE [TURBO])

NG

6.CHECK HARNESS AND CONNECTOR (MASS AIR FLOW METER - ECM)
4.READ VALUE USING INTELLIGENT TESTER (INTAKE AIR TEMPERATURE [TURBO])
a.

Connect the intelligent tester to the DLC3.


b.

Turn the ignition switch to ON and turn the tester on.


c.

Enter the following menus: Powertrain / Engine and ECT / Data List / Intake Air Temp (Turbo).


d.

Read the value.

OK:

The difference between the displayed value and outside air temperature is below 15°C (27°F).



Result:
Proceed to
OK
NG



OK

5.REPLACE ECM

NG

8.CHECK HARNESS AND CONNECTOR (INTAKE AIR TEMPERATURE SENSOR (TURBO) - ECM)
5.REPLACE ECM

Result:
Proceed to
NEXT



NEXT

11.CONFIRM WHETHER MALFUNCTION HAS BEEN SUCCESSFULLY REPAIRED
6.CHECK HARNESS AND CONNECTOR (MASS AIR FLOW METER - ECM)
a.

Disconnect the mass air flow meter connector.


b.

Disconnect the ECM connector.


c.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
C115-1 (THA) - C113-6 (THA) Always Below 1 Ω
C115-2 (E2) - C114-14 (E2) Always Below 1 Ω
C115-1 (THA) or C113-6 (THA) - Body ground Always 10 kΩ or higher



d.

Reconnect the mass air flow meter connector.


e.

Reconnect the ECM connector.


Result:
Proceed to
OK
NG



OK

7.REPLACE MASS AIR FLOW METER

NG

10.REPAIR OR REPLACE HARNESS AND CONNECTOR
7.REPLACE MASS AIR FLOW METER
a.

Replace the mass air flow meter.

Click hereEngine / Hybrid System>1KD-FTV ENGINE CONTROL>MASS AIR FLOW METER(w/ Glow Plug Controller)>REMOVAL

HINT:

If foreign matter is stuck inside the mass air flow meter, the output characteristics of the mass air flow meter may change, resulting in a malfunction.



Result:
Proceed to
NEXT



NEXT

11.CONFIRM WHETHER MALFUNCTION HAS BEEN SUCCESSFULLY REPAIRED
8.CHECK HARNESS AND CONNECTOR (INTAKE AIR TEMPERATURE SENSOR (TURBO) - ECM)
a.

Disconnect the intake air temperature sensor (turbo) connector.


b.

Disconnect the ECM connector.


c.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
C18-2 - C113-3 (THIA) Always Below 1 Ω
C18-1 - C114-14 (E2) Always Below 1 Ω
C18-2 or C113-3 (THIA) - Body ground Always 10 kΩ or higher



d.

Reconnect the intake air temperature sensor (turbo) connector.


e.

Reconnect the ECM connector.


Result:
Proceed to
OK
NG



OK

9.REPLACE INTAKE AIR TEMPERATURE SENSOR (TURBO)

NG

10.REPAIR OR REPLACE HARNESS AND CONNECTOR
9.REPLACE INTAKE AIR TEMPERATURE SENSOR (TURBO)

Result:
Proceed to
NEXT



NEXT

11.CONFIRM WHETHER MALFUNCTION HAS BEEN SUCCESSFULLY REPAIRED
10.REPAIR OR REPLACE HARNESS AND CONNECTOR
a.

Repair or replace the harness or connector.


Result:
Proceed to
NEXT



NEXT

11.CONFIRM WHETHER MALFUNCTION HAS BEEN SUCCESSFULLY REPAIRED
11.CONFIRM WHETHER MALFUNCTION HAS BEEN SUCCESSFULLY REPAIRED
a.

Allow the engine to soak for 1 to 2 hours.

HINT:
·

It is not necessary to allow the engine to soak if the engine is cold.

·

The engine cools faster if the hood is opened.




b.

Connect the intelligent tester to the DLC3.


c.

Turn the ignition switch to ON and turn the tester on.


d.

Enter the following menus: Powertrain / Engine and ECT / Data List / Coolant temp.


e.

Read the value.

NOTICE:

If the difference between "Coolant Temp" and the outside air temperature is 5°C (9°F) or higher, the heat from the engine affects the intake air temperature sensor, causing an incorrect value to be displayed. In this case, allow the engine to soak again.



f.

Enter the following menus: Powertrain / Engine and ECT / Data List / Intake Air and Intake Air Temp (Turbo).


g.

Read the value.

OK:

The difference between the displayed value and outside air temperature is below 15°C (27°F).



Result:
Proceed to
NEXT



NEXT

END