This DTC relates to the oil control valve.
The Variable Valve Timing (VVT) system includes the ECM, intake camshaft timing oil control valve assembly and VVT controller. The ECM sends a target duty cycle control signal to the intake camshaft timing oil control valve assembly. This control signal regulates the oil pressure applied to the VVT controller. Camshaft timing control is performed according to engine operating conditions such as the intake air volume, throttle valve position and engine coolant temperature. The ECM controls the intake camshaft timing oil control valve assembly based on the signals transmitted by several sensors. The VVT controller regulates the intake camshaft angle using oil pressure through the intake camshaft timing oil control valve assembly. As a result, the relative positions of the camshaft and crankshaft are optimized, the engine torque and fuel economy improve, and the exhaust emissions decrease under overall driving conditions. The ECM detects the actual intake valve timing using signals from the camshaft and crankshaft position sensors and performs feedback control. This is how the target intake valve timing is verified by the ECM.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Memory |
|---|---|---|---|---|---|
| P0010 | Camshaft Position "A" Actuator Circuit (Bank 1) | An open or short in the camshaft timing oil control valve circuit (1 trip detection logic). | ·
Open or short in camshaft timing oil control valve circuit ·
Camshaft timing oil control valve assembly ·
ECM |
Comes on | DTC stored |
Read freeze frame data using the intelligent tester. Freeze frame data records the engine condition when malfunctions are detected. When troubleshooting, freeze frame data can help determine if the vehicle was moving or stationary, if the engine was warmed up or not, if the air fuel ratio was lean or rich, and other data from the time the malfunction occurred.
Connect the intelligent tester to the DLC3.
Start the engine.
Turn the tester on.
Enter the following menus: Powertrain / Engine and ECT / Active Test / Control the VVT Linear (Bank 1).
| Tester Display |
|---|
| Control the VVT Linear (Bank1) |
Check the engine speed while operating the camshaft timing oil control valve using the intelligent tester.
When performing the Active Test, make sure the air conditioning is on.
Make sure the engine coolant temperature when the engine is started is 30°C (86°F) or less.
| Tester Operation | Specified Condition |
|---|---|
| 0% | Normal engine speed |
| 100% | Engine idles roughly or stalls |
Refer to "Data List / Active Test" [VVT OCV Duty #1 and VVT Change Angle #1].
Click hereEngine / Hybrid System>2TR-FBE ENGINE CONTROL>SFI SYSTEM>DATA LIST / ACTIVE TEST
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Inspect the camshaft timing oil control valve assembly.
Click hereEngine / Hybrid System>2TR-FBE ENGINE CONTROL>CAMSHAFT OIL CONTROL VALVE>INSPECTION
Connect the positive (+) battery terminal to terminal 1 and the negative (-) battery terminal to terminal 2. Check the valve operation.
Valve moves quickly.
Reinstall the camshaft timing oil control valve assembly.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the camshaft timing oil control valve assembly connector.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| C74-2 - C96-14 (OC1+) | Always | Below 1 Ω |
| C74-1 - C96-9 (OC1-) | Always | Below 1 Ω |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| C74-2 or C96-14 (OC1+) - Body ground | Always | 10 kΩ or higher |
| C74-1 or C96-9 (OC1-) - Body ground | Always | 10 kΩ or higher |
Reconnect the camshaft timing oil control valve assembly connector.
Reconnect the ECM connector.
| Proceed to |
|---|
| OK |
| NG |
OK
NG