Refer to DTC P2006.
Click hereEngine / Hybrid System>1GD-FTV ENGINE CONTROL>ECD SYSTEM(for i-ART)>P2006
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Memory |
|---|---|---|---|---|---|
| P2009 | Intake Manifold Runner Control Circuit Low (Bank 1) | Open in vacuum switching valve (for swirl control valve) circuit for 0.5 seconds (2 trip detection logic). | ·
Vacuum switching valve (for swirl control valve) ·
Open in vacuum switching valve (for swirl control valve) circuit ·
ECM |
Comes on | DTC stored |
| P2010 | Intake Manifold Runner Control Circuit High (Bank 1) | Short in vacuum switching valve (for swirl control valve) circuit for 0.5 seconds (2 trip detection logic). | ·
Vacuum switching valve (for swirl control valve) ·
Short in vacuum switching valve (for swirl control valve) circuit ·
ECM |
Comes on | DTC stored |
| DTC No. | DTC Detection Drive Pattern |
|---|---|
| P2009
P2010 |
2 seconds after engine is started, race engine for 1 second |
Refer to DTC P2006.
Click hereEngine / Hybrid System>1GD-FTV ENGINE CONTROL>ECD SYSTEM(for i-ART)>P2006
Inspect the fuses of circuits related to this system before performing the following inspection procedure.
After replacing the ECM, the new ECM needs registration (Click here Engine / Hybrid System>1GD-FTV ENGINE CONTROL>ECD SYSTEM(for i-ART)>REGISTRATION) and initialization (Click here Engine / Hybrid System>1GD-FTV ENGINE CONTROL>ECD SYSTEM(for i-ART)>INITIALIZATION).
Read freeze frame data using the GTS. Freeze frame data records the engine condition when malfunctions are detected. When troubleshooting, freeze frame data can help determine if the vehicle was moving or stationary, if the engine was warmed up or not, and other data from the time the malfunction occurred.
Connect the GTS to the DLC3.
Disconnect the vacuum hoses from the vacuum switching valve (for swirl control valve).
Turn the engine switch on (IG) and turn the GTS on.
Enter the following menus: Powertrain / Engine / Active Test / Activate the VSV for Swirl Control Valve.
| Tester Display |
|---|
| Activate the VSV for Swirl Control Valve |
Check the VSV operation when it is operated using the GTS.
| GTS Operation | Specified Condition |
|---|---|
| VSV ON | Air from port E flows out through port F |
| VSV OFF | Air from port E flows out through air filter |
Reconnect the vacuum hoses.
| Proceed to |
|---|
| OK |
| NG |
OK
Click hereEngine / Hybrid System>1GD-FTV ENGINE CONTROL>ECD SYSTEM(for i-ART)>CHECK FOR INTERMITTENT PROBLEMS
NG
Inspect the vacuum switching valve (for swirl control valve).
Click hereEngine / Hybrid System>1GD-FTV INTAKE / EXHAUST>INTAKE MANIFOLD>INSPECTION
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the vacuum switching valve (for swirl control valve) connector.
| *a | Front view of wire harness connector
(to Vacuum Switching Valve (for Swirl Control Valve)) |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| C110-2 (SCV+) - Body ground | Engine switch on (IG) | 11 to 14 V |
Reconnect the vacuum switching valve (for swirl control valve) connector.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the vacuum switching valve (for swirl control valve) connector.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| C110-1 (SCV-) - C38-10 (SCV) | Always | Below 1 Ω |
| C110-1 (SCV-) or C38-10 (SCV) - Body ground and other terminals | Always | 10 kΩ or higher |
Reconnect the vacuum switching valve (for swirl control valve) connector.
Reconnect the ECM connector.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Replace the ECM.
Click hereEngine / Hybrid System>1GD-FTV ENGINE CONTROL>ECM>REMOVAL
| Proceed to |
|---|
| NEXT |
NEXT
Replace the vacuum control valve set.
Click hereEngine / Hybrid System>1GD-FTV INTAKE / EXHAUST>INTAKE MANIFOLD>REMOVAL
| Proceed to |
|---|
| NEXT |
NEXT
Remove the instrument panel junction block connector.
Disconnect the vacuum switching valve (for swirl control valve) connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 2G-3 - C110-2 (SCV+) | Always | Below 1 Ω |
| 2G-3 or C110-2 (SCV+) - Body ground and other terminals | Always | 10 kΩ or higher |
Reinstall the instrument panel junction block connector.
Reconnect the vacuum switching valve (for swirl control valve) connector.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Check the ECM power source circuit.
Click hereEngine / Hybrid System>1GD-FTV ENGINE CONTROL>ECD SYSTEM(for i-ART)>ECM Power Source Circuit
| Proceed to |
|---|
| NEXT |
NEXT
Repair or replace harness or connector.
| Proceed to |
|---|
| NEXT |
NEXT
Connect the GTS to the DLC3.
Clear the DTCs.
Start the engine and wait for 3 seconds or more.
Enter the following menus: Powertrain / Engine / Trouble Codes.
Confirm that the DTC is not output again.
| Proceed to |
|---|
| NEXT |
NEXT