The electromagnetic oil pump is installed inside the automatic transmission assembly.
The electromagnetic oil pump operates from the time the engine is stopped due to stop and start control until the vehicle starts moving again in order to ensure oil pressure within the automatic transmission assembly and allow for a smooth start-off.
The engine stop and start ECU supplies power from the backup boost converter to the electromagnetic oil pump through Tr1 and performs Tr2 duty control to operate the electromagnetic oil pump.
The engine stop and start ECU performs Tr1 and Tr2 control when operating or not operating the electromagnetic oil pump and during the preliminary check, and also monitors the EGND terminal to record DTCs.
As a preliminary check, the first time the vehicle speed reaches 2 km/h (1.2 mph) or more on each trip and every time the vehicle speed reaches 2km/h (1.2 mph) or more after stop and start control is performed, the engine stop and start ECU turns Tr1 ON and checks that there are no malfunctions in the electromagnetic oil pump circuit.
The engine stop and start solenoid filter absorbs high-voltage counter-electromotive force generated when the electromagnetic oil pump operates.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | Warning Indicate | Memory |
|---|---|---|---|---|---|
| P2796 | Electromagnetic Oil Pump Circuit | ·
Electromagnetic oil pump not operating: Tr1: OFF, Tr2: OFF The following condition is met for 2 seconds (1 trip detection logic):
·
EGND terminal voltage 10 V or higher ·
Electromagnetic oil pump operating: Tr1: ON, Tr2: Operating Either condition is met for 0.21 seconds (2 trip detection logic):
·
EGND terminal voltage 10 V or higher ·
EGND terminal voltage below 1 V ·
During electromagnetic oil pump preliminary check: First time vehicle speed reaches 2 km/h or higher once per driving cycle Both conditions are met for 0.16 seconds (2 trip detection logic):
·
Tr1: ON, Tr2: OFF ·
EGND terminal voltage below 1 V |
·
Engine stop and start ECU ·
Electromagnetic oil pump ·
Engine stop and start solenoid filter ·
Transmission wire ·
Wire harness or connector |
Blinks | DTC stored |
DTCs for the stop and start system are not cleared even if the malfunction has been repaired. After repairing the malfunction, be sure to clear the DTCs.
Click hereEngine / Hybrid System>STOP AND START>STOP AND START SYSTEM>DTC CHECK / CLEAR
CONFIRMATION AFTER TROUBLESHOOTING
If the cable is disconnected from the battery terminal, stop and start control is prohibited until refresh charge is completed.
In this case, let the vehicle idle with the battery temperature at 11°C (51°F) or higher for 5 to 60 minutes to complete the refresh charge. (The refresh charge is complete when the Data List item Status of Battery Charge Control changes from "Refresh Charge Mode".)
If the GTS is not available and the Data List item Status of Battery Charge Control cannot be checked, charge the battery by idling the engine for approximately 5 to 60 minutes or driving the vehicle, and then drive the vehicle and check that stop and start control operates.
If the engine is started with the hood open, the system determines that a jump start has occurred. Therefore, make sure that the hood is closed before starting the engine and driving the vehicle.
After the refresh charge completes, turn the engine switch off, wait for at least 30 seconds, and then start the engine again.
If the vehicle enters refresh charge mode again while the engine is idling, the initial refresh charge did not properly complete, so wait for the refresh charge to complete.
Allow the engine to idle for 3 minutes after the engine warms up and check that the engine speed is within 50 rpm of the target idle speed.
Connect the GTS to the DLC3.
Turn the ignition switch to ON and turn the GTS on.
Clear the DTCs.
Start the engine and warm it up.
Drive the vehicle at 7 km/h (4.3 mph) or more.
When performing Confirmation Driving Pattern, obey all speed limits and traffic laws.
Depress the brake pedal and stop the vehicle.
Keep the engine stopped by stop and start control. (Keep the shift lever in D.)
Release the brake pedal with the shift lever in D to start the engine.
Check that no DTCs are output.
STOP AND START SYSTEM OPERATION CHECK
If the cable is disconnected from the battery terminal, stop and start control is prohibited until refresh charge is completed.
In this case, let the vehicle idle with the battery temperature at 11°C (51°F) or higher for 5 to 60 minutes to complete the refresh charge. (The refresh charge is complete when the Data List item Status of Battery Charge Control changes from "Refresh Charge Mode".)
If the GTS is not available and the Data List item Status of Battery Charge Control cannot be checked, charge the battery by idling the engine for approximately 5 to 60 minutes or driving the vehicle, and then drive the vehicle and check that stop and start control operates.
If the engine is started with the hood open, the system determines that a jump start has occurred. Therefore, make sure that the hood is closed before starting the engine and driving the vehicle.
After the refresh charge completes, turn the engine switch off, wait for at least 30 seconds, and then start the engine again.
If the vehicle enters refresh charge mode again while the engine is idling, the initial refresh charge did not properly complete, so wait for the refresh charge to complete.
Start the engine and warm it up.
Turn the air conditioning system off.
Drive the vehicle at 7 km/h (4.3 mph) or more.
When performing Confirmation Driving Pattern, obey all speed limits and traffic laws.
Depress the brake pedal and stop the vehicle.
Allow the engine to stop by stop and start control. (Keep the shift lever in D.)
Release the brake pedal with the shift lever in D to start the engine.
Before replacing the engine stop and start ECU, read the number of starter operations and total number of engine starts and write it into a new engine stop and start ECU.
Click hereEngine / Hybrid System>STOP AND START>STOP AND START SYSTEM>REGISTRATION
After replacing the engine stop and start ECU or air conditioning amplifier assembly, reset and perform learning of the air conditioning information in the engine stop and start ECU.
Click hereEngine / Hybrid System>STOP AND START>STOP AND START SYSTEM>REGISTRATION
After replacing the engine stop and start ECU or airbag sensor assembly, clear and calibrate the deceleration sensor zero point in the engine stop and start ECU.
Click hereEngine / Hybrid System>STOP AND START>STOP AND START SYSTEM>REGISTRATION
When the electromagnetic oil pump or engine stop and start ECU is replaced, check the electromagnetic oil pump.
Click hereEngine / Hybrid System>STOP AND START>STOP AND START SYSTEM>REGISTRATION
Using the GTS, read the freeze frame data before troubleshooting. System condition information is recorded as freeze frame data the moment a DTC is stored. This information can be useful when troubleshooting.
Click hereEngine / Hybrid System>STOP AND START>STOP AND START SYSTEM>FREEZE FRAME DATA
Connect the GTS to the DLC3.
Turn the ignition switch to ON.
Turn the GTS on.
Enter the following menus: Powertrain / Stop and Start / Trouble Codes.
Read the DTCs
| Result | Proceed to |
|---|---|
| DTC P2796 is output | A |
| DTC P2796 and B22C0 are output | B |
A
B
The freeze frame data is cleared when DTCs are cleared. Be sure to make a note of necessary data in advance.
According to the display on the GTS, select DTC P2796 and check the sets of freeze frame data.
Click hereEngine / Hybrid System>STOP AND START>STOP AND START SYSTEM>FREEZE FRAME DATA
| Tester Display | Result | Proceed to |
|---|---|---|
| Electromagnetic Oil Pump Abnormal When Non Drive | ON | A |
| Electromagnetic Oil Pump Abnormal When Preliminarily Check | ON | B |
| Electromagnetic Oil Pump Abnormal When Non Drive, Electromagnetic Oil Pump Abnormal When Preliminarily Check and Electromagnetic Oil Pump Abnormal When Drive | OFF | |
| Electromagnetic Oil Pump Abnormal When Drive | ON | C |
A
B
C
| *a | Component with harness connected
(Engine Stop and Start ECU) |
- | - |
Turn the ignition switch to ON.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Result | Proceed to |
|---|---|---|---|
| G127-8 (EGND) - Body ground | Ignition switch ON | 10 to 14 V | A |
| Below 1 V | B |
A
B
Click hereGeneral>INTRODUCTION>HOW TO TROUBLESHOOT ECU CONTROLLED SYSTEMS>HOW TO PROCEED WITH TROUBLESHOOTING
| *a | Component with harness connected
(Engine Stop and Start ECU) |
- | - |
Disconnect the C42 transmission wire connector.
Turn the ignition switch to ON.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Result | Proceed to |
|---|---|---|---|
| G127-8 (EGND) - Body ground | Ignition switch ON | 10 to 14 V | A |
| Below 1 V | B |
A
B
| *a | Front view of wire harness connector
(to Engine Stop and Start ECU) |
Disconnect the engine stop and start ECU connector.
Turn the ignition switch to ON.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Result | Proceed to |
|---|---|---|---|
| G127-8 (EGND) - Body ground | Ignition switch ON | 10 to 14 V | A |
| Below 1 V | B |
A
B
| *a | Front view of wire harness connector
(to Transmission Wire) |
Disconnect the C42 transmission wire connector.
Turn the ignition switch to ON.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Result | Proceed to |
|---|---|---|---|
| C42-17 (EMP+) - Body ground | Ignition switch ON | 10 to 14 V | A |
| Below 1 V | B |
A
B
| *a | Front view of wire harness connector
(to Transmission Wire) |
Disconnect the G127 engine stop and start ECU connector.
Disconnect the transmission wire connector.
Turn the ignition switch to ON.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Result | Proceed to |
|---|---|---|---|
| C42-17 (EMP+) - Body ground | Ignition switch ON | 10 to 14 V | A |
| Below 1 V | B |
A
B
| *1 | Electromagnetic Oil Pump |
Remove the electromagnetic oil pump.
Click hereDrivetrain>AC60F AUTOMATIC TRANSMISSION / TRANSAXLE>VALVE BODY ASSEMBLY>DISASSEMBLY
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1 - 2 | 20°C (68°F) | 5.0 to 5.6 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| *a | Component with harness connected
(Engine Stop and Start ECU) |
- | - |
Connect an oscilloscope to terminals G127-8 (EGND) and G125-8 (GND1).
Enter the following menus: Powertrain / Stop and Start / Active Test / Electromagnetic Oil Pump.
Check the waveform while performing the Active Test.
| Item | Condition |
|---|---|
| Tester Connection | G127-8 (EGND) - G125-8 (GND1) |
| Tool Setting | 10 V/DIV., 20 ms./DIV. |
| Condition | ·
Ignition switch ON (engine is stopped) ·
Active Test "Electromagnetic Oil Pump" being performed |
The waveform is similar to that shown in the illustration.
| Result | Proceed to |
|---|---|
| Constant value below 1 V | A |
| Constant value between 10 to 14 V | B |
| Waveform output as in illustration | C |
A
B
C
Click hereGeneral>INTRODUCTION>HOW TO TROUBLESHOOT ECU CONTROLLED SYSTEMS>HOW TO PROCEED WITH TROUBLESHOOTING
| *a | Component with harness connected
(Engine Stop and Start ECU) |
- | - |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Result | Proceed to |
|---|---|---|---|
| G127-8 (EGND) - Body ground | Ignition switch off | Below 1 Ω | A |
| 10 kΩ or higher | B |
A
B
| *a | Front view of wire harness connector
(to Engine Stop and Start ECU) |
Disconnect the G127 engine stop and start ECU connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Result | Proceed to |
|---|---|---|---|
| G127-8 (EGND) - Body ground | Always | 10 kΩ or higher | A |
| Below 1 Ω | B |
A
B
| *a | Front view of wire harness connector
(to Engine Stop and Start ECU) |
Disconnect the C42 transmission wire connector.
Disconnect the G127 engine stop and start ECU connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Result | Proceed to |
|---|---|---|---|
| G127-8 (EGND) - Body ground | Always | 10 kΩ or higher | A |
| Below 1 Ω | B |
A
B
| *1 | Electromagnetic Oil Pump |
Remove the electromagnetic oil pump.
Click hereDrivetrain>AC60F AUTOMATIC TRANSMISSION / TRANSAXLE>VALVE BODY ASSEMBLY>DISASSEMBLY
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1 - 2 | 20°C (68°F) | 5.0 to 5.6 Ω |
| 1 - Body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| *a | Front view of wire harness connector
(to Transmission Wire) |
Disconnect the C42 transmission wire connector.
Connect the GTS to the DLC3.
Turn the ignition switch to ON.
Turn the GTS on.
Enter the following menus: Powertrain / Stop and Start / Active Test / Electromagnetic Oil Pump.
| Tester Display |
|---|
| Electromagnetic Oil Pump |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Result | Proceed to |
|---|---|---|---|
| C42-17 (EMP+) - Body ground | ·
Ignition switch ON (engine is stopped) ·
Active Test "Electromagnetic Oil Pump" being performed |
10 to 14 V | A |
| Below 1 V | B |
A
B
Disconnect the C42 transmission wire connector.
| *a | Component without harness connected
(Transmission Wire) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 17 (EMP+) - 27 (EMP-) | 20°C (68°F) | 5.0 to 5.6 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| *1 | Electromagnetic Oil Pump |
Remove the electromagnetic oil pump.
Click hereDrivetrain>AC60F AUTOMATIC TRANSMISSION / TRANSAXLE>VALVE BODY ASSEMBLY>DISASSEMBLY
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1 - 2 | 20°C (68°F) | 5.0 to 5.6 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| *a | Component with harness connected
(Engine Stop and Start ECU) |
- | - |
Disconnect the C42 transmission wire connector.
Connect the GTS to the DLC3.
Turn the ignition switch to ON.
Turn the GTS on.
Enter the following menus: Powertrain / Stop and Start / Active Test / Electromagnetic Oil Pump.
| Tester Display |
|---|
| Electromagnetic Oil Pump |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Result | Proceed to |
|---|---|---|---|
| G127-9 (EMOP) - Body ground | ·
Ignition switch ON (engine is stopped) ·
Active Test "Electromagnetic Oil Pump" being performed |
10 to 14 V | A |
| Below 1 V | B |
A
B
Disconnect the C42 transmission wire connector.
Disconnect the G127 engine stop and start ECU connector.
Measure the resistance according to the value(s) in the table below.
Measure the values on the front side of the connector
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| G127-9 (EMOP) - C42-17 (EMP+) | Always | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
The freeze frame data is cleared when DTCs are cleared. Be sure to make a note of necessary data in advance.
According to the display on the GTS, select DTC P2796 and check the sets of freeze frame data.
Click hereEngine / Hybrid System>STOP AND START>STOP AND START SYSTEM>FREEZE FRAME DATA
| Tester Display | Result | Proceed to |
|---|---|---|
| Electromagnetic Oil Pump Abnormal When Preliminarily Check | ON | A |
| Electromagnetic Oil Pump Abnormal When Drive | ON | B |
| Electromagnetic Oil Pump Abnormal When Preliminarily Check and Electromagnetic Oil Pump Abnormal When Drive | OFF | C |
A
B
C
| *a | Component with harness connected
(Engine Stop and Start ECU) |
- | - |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| G127-9 (EMOP) - Body ground and other terminals | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| *a | Component with harness connected
(Engine Stop and Start ECU) |
- | - |
Disconnect the C42 transmission wire connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| G127-9 (EMOP) - Body ground and other terminals | Always | 10 kΩ or higher |
| Tester Connection | Result | Proceed to |
|---|---|---|
| G127-9 (EMOP) - Body ground and other terminals | 10 kΩ or higher | A |
| Below 1 Ω | B |
A
B
| *1 | Electromagnetic Oil Pump |
Remove the electromagnetic oil pump.
Click hereDrivetrain>AC60F AUTOMATIC TRANSMISSION / TRANSAXLE>VALVE BODY ASSEMBLY>DISASSEMBLY
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 2 - Body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the C42 transmission wire connector.
Disconnect the G127 engine stop and start ECU connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| G127-9 (EMOP) - Body ground and other terminals | Always | 10 kΩ or higher |
| C42-17 (EMP+) - Body ground and other terminals | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| *a | Front view of wire harness connector
(to Engine Stop and Start ECU) |
Disconnect the G127 engine stop and start ECU connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| G127-9 (EMOP) - G127-8 (EGND) | 20°C (68°F) | 5.0 to 5.6 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| *a | Front view of wire harness connector
(to Engine Stop and Start ECU) |
Disconnect the C42 transmission wire connector.
Disconnect G127 the engine stop and start ECU connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| G127-9 (EMOP) - G127-8 (EGND) | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| *1 | Electromagnetic Oil Pump |
Remove electromagnetic oil pump.
Click hereDrivetrain>AC60F AUTOMATIC TRANSMISSION / TRANSAXLE>VALVE BODY ASSEMBLY>DISASSEMBLY
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1 - 2 | 20°C (68°F) | 5.0 to 5.6 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| *a | Component without harness connected
(Engine Stop and Start Solenoid Filter) |
Remove the engine stop and start solenoid filter.
Click hereEngine / Hybrid System>STOP AND START>ENGINE STOP AND START SOLENOID FILTER>REMOVAL
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 2 (MOP+) - 1 (MOP-) | Always | 10 kΩ or higher |
| 7 (MOPI) - 8 (GND) | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| *a | Component with harness connected
(Engine Stop and Start ECU) |
- | - |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| G127-9 (EMOP) - Body ground and other terminals | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| *a | Front view of wire harness connector
(to Engine Stop and Start ECU) |
Disconnect the G127 engine stop and start ECU connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| G127-9 (EMOP) - G127-8 (EGND) | 20°C (68°F) | 5.0 to 5.6 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| *a | Component without harness connected
(Engine Stop and Start ECU) |
- | - |
Disconnect the engine stop and start ECU connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| G127-9 (EMOP) - G127-8 (EGND) | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG