The illuminated entry system controls the engine switch illumination.
Before replacing the certification ECU (smart key ECU assembly), refer to the Service Bulletin.
Connect the GTS to the DLC3.
Turn the ignition switch to ON.
Turn the GTS on.
Enter the following menus: Body Electrical / Entry&Start / Active Test.
Perform the Active Test according to the display on the GTS.
| Tester Display | Measurement Item | Control Range | Diagnostic Note |
|---|---|---|---|
| Power/Engine SW Light | Engine switch illumination | OFF or ON | w/ Smart Entry and Start System |
| Tester Display |
|---|
| Power/Engine SW Light |
Engine switch illumination comes on.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Remove the engine switch.
for 1KD-FTV (for LHD):
Click hereEngine / Hybrid System>1KD-FTV STARTING>ENGINE SWITCH(for LHD)>REMOVAL
for 1KD-FTV (for RHD):
Click hereEngine / Hybrid System>1KD-FTV STARTING>ENGINE SWITCH(for RHD)>REMOVAL
for 1GD-FTV:
Click hereEngine / Hybrid System>1GD-FTV STARTING>ENGINE SWITCH>REMOVAL
for 2TR-FE
Click hereEngine / Hybrid System>2TR-FE STARTING>ENGINE SWITCH>REMOVAL
Inspect the engine switch.
for 1KD-FTV (for LHD):
Click hereEngine / Hybrid System>1KD-FTV STARTING>ENGINE SWITCH(for LHD)>INSPECTION
for 1KD-FTV (for RHD):
Click hereEngine / Hybrid System>1KD-FTV STARTING>ENGINE SWITCH(for RHD)>INSPECTION
for 1GD-FTV:
Click hereEngine / Hybrid System>1GD-FTV STARTING>ENGINE SWITCH>INSPECTION
for 2TR-FE
Click hereEngine / Hybrid System>2TR-FE STARTING>ENGINE SWITCH>INSPECTION
Engine switch illumination is normal.
| Proceed to |
|---|
| OK |
| NG (for 1KD-FTV) |
| NG (for 1GD-FTV) |
| NG (for 2TR-FE) |
OK
NG (for 1KD-FTV)
for LHD:
Click hereEngine / Hybrid System>1KD-FTV STARTING>ENGINE SWITCH(for LHD)>REMOVAL
for RHD:
Click hereEngine / Hybrid System>1KD-FTV STARTING>ENGINE SWITCH(for RHD)>REMOVAL
NG (for 1GD-FTV)
NG (for 2TR-FE)
Disconnect the G81 engine switch connector.
Disconnect the G69 certification ECU (smart key ECU assembly) connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| G81-9 (SWIL) - G69-19 (SWIL) | Always | Below 1 Ω |
| G81-6 (AGND) - G69-24 (AGND) | Always | Below 1 Ω |
| G81-9 (SWIL) or G69-19 (SWIL) - Body ground | Always | 10 kΩ or higher |
| G81-6 (AGND) or G69-24 (AGND) - Body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG