2013-2015 Land Cruiser Prado · Service Manual Engine / Hybrid System

Pre-heating Control Circuit

Circuit diagnosis · Vehicles built from Aug 2014

Versions by build date: Aug 2013 – Jul 2014 from Aug 2014

DESCRIPTION

When the ignition switch is turned to ON, the ECM calculates the glow indicator lighting time/heating corresponding to the coolant temperature at that time and turns on the glow indicator light/glow plug relay (GLOW).
As ceramic is used for glow plug assembly material, current control is not performed.
A018109E02

WIRING DIAGRAM

A269539E01

INSPECTION PROCEDURE

NOTICE:
Inspect the fuses for circuits related to this system before performing the following inspection procedure.


1. CHECK GLOW INDICATOR LIGHT
  1. Turn the ignition switch to ON.

  1. Check that the glow indicator light comes on.

    OK:
    The glow indicator light remains on for 0.5 seconds or more, and then goes off.



NG
Go to step 10
OK


2. CHECK GLOW PLUG ASSEMBLY (INSTALLATION)
  1. Check that the glow plug assembly and glow plug wire are securely installed.

    OK:
    The glow plug assembly and glow plug wire are securely installed.



NG
TIGHTEN GLOW PLUG ASSEMBLY
OK


3. INSPECT GLOW PLUG ASSEMBLY (RESISTANCE)
  1. Inspect the glow plug assembly (Click here).



NG
REPLACE GLOW PLUG ASSEMBLY (Click here)
OK


4. CHECK INDICATOR LIGHTING TIME AND AFTER GLOW TIME


NG
REPLACE ECM (Click here)
OK


5. READ OUTPUT DTC
  1. Connect the intelligent tester to the DLC3.

  1. Turn the ignition switch to ON and turn the tester on.

  1. Enter the following menus: Powertrain / Engine and ECT / DTC.

  1. Read the DTCs (Click here).

    Result 
    Result
    Proceed to
    DTC is not output
    A
    DTC is output
    B



B
GO TO RELEVANT DTC CHART (Click here)
A


6. INSPECT GLOW RELAY ASSEMBLY
  1. Inspect the glow plug relay (GLOW) (Click here).



NG
REPLACE GLOW PLUG RELAY (GLOW)
OK


7. CHECK ECM (SREL VOLTAGE)

  1. A062416E95
    Turn the ignition switch to the start position.

  1. Measure the voltage according to the value(s) in the table below.

    Standard Voltage:
    Tester Connection
    Condition
    Specified Condition
    G61-2 (SREL) - C101-14 (E1)
    Cranking
    11 to 14 V

    Text in Illustration 
    *a
    Component with harness connected
    (ECM)



NG
REPLACE ECM (Click here)
OK


8. CHECK HARNESS AND CONNECTOR (GLOW RELAY - ECM AND BODY GROUND)
  1. Disconnect the ECM connector.

  1. Remove the glow relay from the engine room relay block.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance (Check for Open):
    Tester Connection
    Condition
    Specified Condition
    G61-2 (SREL) - Relay block glow relay terminal 2
    Always
    Below 1 Ω
    Relay block glow relay terminal 1 - Body ground
    Always
    Below 1 Ω

    Standard Resistance (Check for Short):
    Tester Connection
    Condition
    Specified Condition
    G61-2 (SREL) or relay block glow relay terminal 2 - Body ground
    Always
    10 kΩ or higher

  1. Reconnect the ECM connector.

  1. Reinstall the glow relay.



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


9. CHECK HARNESS AND CONNECTOR (GLOW PLUG RELAY (GLOW) - GLOW PLUG ASSEMBLY AND BATTERY)
  1. Disconnect the cable from the negative (-) battery terminal.

  1. Disconnect the cable from the positive (+) battery terminal.

  1. Remove the glow relay from the engine room relay block.

  1. Disconnect the glow plug wire.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance (Check for Open):
    Tester Connection
    Condition
    Specified Condition
    Relay block glow relay terminal 3 - C114-1
    Always
    Below 1 Ω
    Relay block glow relay terminal 5 - Positive (+) battery terminal
    Always
    Below 1 Ω

    NOTICE:
    After reconnecting the battery cable, the radio and clock need to be adjusted as they were previously.

  1. Reinstall the glow relay.

  1. Reconnect the glow plug wire.

  1. Reconnect the cable to the positive (+) battery terminal.

  1. Reconnect the cable to the negative (-) battery terminal.



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE (Click here)

10. CHECK ECM (GIND VOLTAGE)

  1. A062418E17
    Disconnect the ECM connector.

  1. Turn the ignition switch to ON.

  1. Measure the voltage according to the value(s) in the table below.

    Standard Voltage:
    Tester Connection
    Switch Condition
    Specified Condition
    G62-1 (GIND) - C101-14 (E1)
    Ignition switch ON
    11 to 14 V

    Text in Illustration 
    *a
    Rear view of wire harness connector
    (to ECM)

  1. Reconnect the ECM connector.



NG
Go to step 11
OK

REPLACE ECM (Click here)

11. CHECK HARNESS AND CONNECTOR (ECM - COMBINATION METER ASSEMBLY)
  1. Disconnect the combination meter assembly connector.

  1. Disconnect the ECM connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    G7-8 - G62-1 (GIND)
    Always
    Below 1 Ω

  1. Reconnect the combination meter assembly connector.

  1. Reconnect the ECM connector.



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


12. CHECK HARNESS AND CONNECTOR (COMBINATION METER ASSEMBLY - BATTERY)

  1. A121704E06
    Disconnect the combination meter assembly connector.

  1. Turn the ignition switch to ON.

  1. Measure the voltage according to the value(s) in the table below.

    Standard Voltage:
    Tester Connection
    Switch Condition
    Specified Condition
    G6-28 - Body ground
    Ignition switch ON
    11 to 14 V

    Text in Illustration 
    *a
    Front view of wire harness connector
    (to Combination Meter Assembly)

  1. Reconnect the combination meter assembly connector.



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE COMBINATION METER ASSEMBLY (Click here)


← Pre-heating Control Circuit (Aug 2013 – Jul 2014)ECM Power Source Circuit (Aug 2013 – Jul 2014) →