B1412/12 Ambient Temperature Sensor Circuit
Diagnostic trouble codes · Vehicles built from Aug 2014
Versions by build date: Aug 2013 – Jul 2014 from Aug 2014
DESCRIPTION
The cooler thermistor (ambient temperature sensor) is installed in the front part of the cooler condenser assembly to detect the ambient temperature and control the air conditioning auto mode. The sensor connected to the air conditioning amplifier assembly detects fluctuations in the ambient temperature. This data is used for controlling the room temperature. The sensor sends a signal to the air conditioning amplifier assembly. The resistance of the cooler thermistor (ambient temperature sensor) changes in accordance with the cooler thermistor temperature (ambient temperature). As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases.The air conditioning amplifier assembly applies a voltage (5 V) to the cooler thermistor (ambient temperature sensor) and reads voltage changes as changes in the resistance of the cooler thermistor (ambient temperature sensor).
| DTC Code |
DTC Detection Condition |
Trouble Area |
| B1412/12 |
An open or short in the cooler thermistor (ambient temperature sensor) circuit. |
|
WIRING DIAGRAM


INSPECTION PROCEDURE
| 1. READ VALUE USING INTELLIGENT TESTER (AMBIENT TEMPERATURE SENSOR) |
Use the Data List to check if the cooler thermistor (ambient temperature sensor) is functioning properly (Click here).
Air Conditioner Tester Display
Measurement Item/Range
Normal Condition
Diagnostic Note
Ambient Temp Sensor
Cooler thermistor (ambient temperature sensor) /
Min: -23.3°C (-9.94°F)
Max: 65.95°C (150.71°F)
Actual ambient temperature displayed
Open in the circuit: -23.3°C (-9.94°F).
Short in the circuit: 65.95°C (150.71°F).
- OK:
- The display is as specified in the normal condition column.
Result Result
Proceed to
OK (When troubleshooting according to problem symptoms table)
A
OK (When troubleshooting according to the DTC)
B
NG
C
|
|
||||
|
|
||||
| A | ||
| ||
| 2. INSPECT COOLER THERMISTOR (AMBIENT TEMPERATURE SENSOR) |
Remove the cooler thermistor (ambient temperature sensor) (Click here).

Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Condition
Specified Condition
1 - 2
10°C (50°F)
3.00 to 3.73 kΩ
15°C (59°F)
2.45 to 2.88 kΩ
20°C (68°F)
1.95 to 2.30 kΩ
25°C (77°F)
1.60 to 1.80 kΩ
30°C (86°F)
1.28 to 1.47 kΩ
35°C (95°F)
1.00 to 1.22 kΩ
40°C (104°F)
0.80 to 1.00 kΩ
45°C (113°F)
0.65 to 0.85 kΩ
50°C (122°F)
0.50 to 0.70 kΩ
55°C (131°F)
0.44 to 0.60 kΩ
60°C (140°F)
0.36 to 0.50 kΩ
Text in Illustration *a
Sensing Portion
*b
Resistance
*c
Allowable Range
*d
Temperature
- NOTICE:
- Even slightly touching the sensor may change the resistance value. Be sure to hold the connector of the sensor.
- When measuring, the sensor temperature must be the same as the ambient temperature.
- Even slightly touching the sensor may change the resistance value. Be sure to hold the connector of the sensor.
- HINT:
- As the temperature increases, the resistance decreases (refer to the graph).
|
|
||||
| OK | |
| 3. CHECK HARNESS AND CONNECTOR (AMBIENT TEMPERATURE SENSOR - AIR CONDITIONING AMPLIFIER) |
Disconnect the A1 sensor connector.
Disconnect the G25 amplifier connector.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Condition
Specified Condition
A1-1 - G25-5 (TAM)
Always
Below 1 Ω
A1-2 - G25-13 (SG-2)
G25-5 (TAM) - Body ground
Always
10 kΩ or higher
G25-13 (SG-2) - Body ground
|
|
||||
| OK | ||
| ||