B14A2 Driver Side Solar Sensor Short Circuit
Diagnostic trouble codes · Vehicles built from Aug 2014
Versions by build date: Aug 2013 – Jul 2014 from Aug 2014
DESCRIPTION


The automatic light control sensor (solar sensor), which is installed on the upper side of the instrument panel, detects sunlight and controls the air conditioning in auto mode. The output current from the automatic light control sensor (solar sensor) varies according to the amount of sunlight. When the amount of sunlight increases, the output current increases. As the amount of sunlight decreases, the output current decreases. The air conditioning amplifier assembly detects the output current from the automatic light control sensor (solar sensor).
| DTC Code |
DTC Detection Condition |
Trouble Area |
| B14A2 |
An open or short in the driver side solar sensor circuit. |
|
WIRING DIAGRAM


INSPECTION PROCEDURE
- HINT:
- If DTC B1244 is output together with other DTCs, troubleshoot DTC B1244 first (Click here).
- If the check is performed in a dark place, DTC B14A2 or B14A3 (solar sensor circuit abnormal) may be stored even though the system is normal.
- If DTC B1244 is output together with other DTCs, troubleshoot DTC B1244 first (Click here).
| 1. READ VALUE USING INTELLIGENT TESTER (SOLAR SENSOR) |
Use the Data List to check if the automatic light control sensor (solar sensor) is functioning properly (Click here).
Air Conditioner Tester Display
Measurement Item/Range
Normal Condition
Diagnostic Note
Solar Sensor (D side)
Automatic light control sensor (solar sensor) / Min.: 0, Max.: 255
Driver side solar sensor voltage increases as brightness increases
Open in the circuit: 0.
Short in the circuit: 255.
- OK:
- The display is as specified in the normal condition column.
Result Result
Proceed to
OK (When troubleshooting according to problem symptoms table)
A
OK (When troubleshooting according to the DTC)
B
NG
C
|
|
||||
|
|
||||
| A | ||
| ||
| 2. CHECK HARNESS AND CONNECTOR (POWER SOURCE CIRCUIT) |
Disconnect the H19 sensor connector.

Measure the voltage according to the value(s) in the table below.
- Standard Voltage:
Tester Connection
Switch Condition
Specified Condition
H19-6 (CLTB) - H19-3 (CLTE)
Ignition switch off
Below 1 V
H19-6 (CLTB) - H19-3 (CLTE)
Ignition switch ON
11 to 14 V
Text in Illustration *a
Front view of wire harness connector
(to Automatic Light Control Sensor [Solar Sensor])
|
|
||||
| OK | |
| 3. CHECK HARNESS AND CONNECTOR (SOLAR SENSOR - AIR CONDITIONING AMPLIFIER) |
Disconnect the H19 sensor connector.
Disconnect the G25 amplifier connector.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
for LHD Tester Connection
Condition
Specified Condition
H19-1 (TSL) - G25-33 (TSD)
Always
Below 1 Ω
H19-1 (TSL) - Body ground
Always
10 kΩ or higher
for RHD Tester Connection
Condition
Specified Condition
H19-2 (TSR) - G25-33 (TSD)
Always
Below 1 Ω
H19-2 (TSR) - Body ground
Always
10 kΩ or higher
|
|
||||
| OK | |
| 4. CHECK AUTOMATIC LIGHT CONTROL SENSOR (SOLAR SENSOR) |
- *1: for LHD
- *2: for RHD
Remove the automatic light control sensor (solar sensor) with its connector still connected (Click here).

Measure the voltage according to the value(s) in the table below.
- Standard Voltage:
for LHD Tester Connection
Switch Condition
Specified Condition
H19-1 (TSL) - H19-3 (CLTE)
Ignition switch ON
Sensor subjected to electric light
0.8 to 4.3 V
H19-1 (TSL) - H19-3 (CLTE)
Ignition switch ON
Sensor covered with cloth
Below 0.8 V
for RHD Tester Connection
Switch Condition
Specified Condition
H19-2 (TSR) - H19-3 (CLTE)
Ignition switch ON
Sensor subjected to electric light
0.8 to 4.3 V
H19-2 (TSR) - H19-3 (CLTE)
Ignition switch ON
Sensor covered with cloth
Below 0.8 V
Text in Illustration *A
for LHD
*B
for RHD
*a
Component with harness connected
(Automatic Light Control Sensor [Solar Sensor])
- NOTICE:
- The connection procedure for using a digital tester such as a TOYOTA electrical tester is shown above. When using an analog tester, connect the negative (-) lead to terminal 1*1 or 2*2 and the positive (+) lead to terminal 3 of the solar sensor.
- HINT:
- Use an incandescent light for inspection. Bring it within about 30 cm (11.8 in.) of the solar sensor.
- As the inspection light is moved away from the sensor, the voltage decreases.
- Use an incandescent light for inspection. Bring it within about 30 cm (11.8 in.) of the solar sensor.
|
|
||||
| OK | ||
| ||
| 5. CHECK HARNESS AND CONNECTOR (MAIN BODY ECU - SOLAR SENSOR) |
Disconnect the G64 ECU connector.
Disconnect the H19 sensor connector.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Condition
Specified Condition
G64-22 (CLTE) - H19-3 (CLTE)
Always
Below 1 Ω
G64-20 (CLTB) - H19-6 (CLTB)
Always
Below 1 Ω
G64-22 (CLTE) - Body ground
Always
10 kΩ or higher
G64-20 (CLTB) - Body ground
Always
10 kΩ or higher
|
|
||||
| OK | ||
| ||