Refer to DTC P0136 (See page Engine / Hybrid System>1GR-FE (ENGINE CONTROL)>SFI SYSTEM>P0136).
Sensor 2 refers to the sensor mounted behind the Three-Way Catalytic Converter (TWC) and located far from the engine assembly.
When any of these DTCs are stored, the ECM enters fail-safe mode. The ECM turns off the heated oxygen sensor heater in fail-safe mode. The ECM continues operating in fail-safe mode until the engine switch is turned off.
The ECM provides a pulse-width modulated control circuit to adjust the current through the heater. The heated oxygen sensor heater circuit uses a relay on the +B side of the circuit.
| DTC No. | DTC Detection Condition | Trouble Area |
|---|---|---|
| P0037
P0057 |
The heated oxygen sensor heater (bank 1, 2 sensor 2) current is below 0.3 A (1 trip detection logic). | ·
Open in heated oxygen sensor heater (bank 1, 2 sensor 2) circuit ·
Heated oxygen sensor heater (bank 1, 2 sensor 2) ·
EFI No. 2 fuse ·
ECM |
| P0038
P0058 |
The heated oxygen sensor (bank 1, 2 sensor 2) current is higher than 2 A (1 trip detection logic). | ·
Short in heated oxygen sensor (bank 1, 2 sensor 2) circuit ·
Heated oxygen sensor heater (bank 1, 2 sensor 2) ·
EFI No. 2 fuse ·
ECM |
| P102D
P105D |
The heated oxygen sensor heater (bank 1, 2 sensor 2) current is higher than a specified value while the heater is not operating (1 trip detection logic). | ECM |
Bank 1 refers to the bank that includes the No. 1 cylinder.
Bank 2 refers to the bank that does not include the No. 1 cylinder.
Sensor 1 refers to the sensor closest to the engine assembly.
Sensor 2 refers to the sensor farthest away from the engine assembly.
The sensing portion of the heated oxygen sensor has a zirconia element which is used to detect the oxygen concentration in the exhaust gas. If the zirconia element is at the appropriate temperature and the difference between the oxygen concentrations surrounding the inside and outside surfaces of the sensor is large, the zirconia element generates voltage signals. In order to increase the oxygen concentration detecting capacity of the zirconia element, the ECM supplements the heat from the exhaust with heat from a heating element inside the sensor.
The ECM monitors the current applied to the heated oxygen sensor heater to check the heater for malfunctions. If the heater current is outside the normal range, the signal transmitted by the heated oxygen sensor becomes inaccurate. When the current in the heated oxygen sensor heater is outside the normal operating range, the ECM interprets this as a malfunction in the sensor and stores a DTC.
Refer to DTC P0136 (See page Engine / Hybrid System>1GR-FE (ENGINE CONTROL)>SFI SYSTEM>P0136).
Inspect the fuses for circuits related to this system before performing the following inspection procedure.
Read freeze frame data using the GTS. Freeze frame data records the engine condition when malfunctions are detected. When troubleshooting, freeze frame data can help determine if the vehicle was moving or stationary, if the engine was warmed up or not, if the air fuel ratio was lean or rich, and other data from the time the malfunction occurred.
Inspect the heated oxygen sensor (See page Engine / Hybrid System>1GR-FE (ENGINE CONTROL)>HEATED OXYGEN SENSOR>INSPECTION).
OK
NG
Disconnect the heated oxygen sensor connector.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| C27-2 (+B) - Body ground | Engine switch on (IG) | 11 to 14 V |
| C145-2 (+B) - Body ground | Engine switch on (IG) | 11 to 14 V |
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| C27-2 (+B) - Body ground | Engine switch on (IG) | 11 to 14 V |
| C28-2 (+B) - Body ground | Engine switch on (IG) | 11 to 14 V |
| *A | for Manual Transmission |
| *B | for Automatic Transmission |
| *a | Front view of wire harness connector
(to Heated Oxygen Sensor Bank 1) |
| *b | Front view of wire harness connector
(to Heated Oxygen Sensor Bank 2) |
| *c | Front view of wire harness connector
(to Heated Oxygen Sensor Bank 2) |
Reconnect the heated oxygen sensor connector.
OK
NG
Disconnect the heated oxygen sensor connector.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| C27-1 (HT1B) - C37-18 (HT1B) | Always | Below 1 Ω |
| C145-1 (HT2B) - C37-13 (HT2B) | Always | Below 1 Ω |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| C27-1 (HT1B) - C37-12 (HT1B) | Always | Below 1 Ω |
| C28-1 (HT2B) - C37-13 (HT2B) | Always | Below 1 Ω |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| C27-1 (HT1B) or C37-18 (HT1B) - Body ground | Always | 10 kΩ or higher |
| C145-1 (HT2B) or C37-13 (HT2B) - Body ground | Always | 10 kΩ or higher |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| C27-1 (HT1B) or C37-12 (HT1B) - Body ground | Always | 10 kΩ or higher |
| C28-1 (HT2B) or C37-13 (HT2B) - Body ground | Always | 10 kΩ or higher |
Reconnect the ECM connector.
Reconnect the heated oxygen sensor connector.
OK
NG
Disconnect the heated oxygen sensor connector.
Remove the No. 1 integration relay from the engine room relay block.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| C27-2 (+B) - 1B-4 | Always | Below 1 Ω |
| C145-2 (+B) - 1B-4 | Always | Below 1 Ω |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| C27-2 (+B) - 1B-4 | Always | Below 1 Ω |
| C28-2 (+B) - 1B-4 | Always | Below 1 Ω |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| C27-2 (+B) or 1B-4 - Body ground | Always | 10 kΩ or higher |
| C145-2 (+B) or 1B-4 - Body ground | Always | 10 kΩ or higher |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| C27-2 (+B) or 1B-4 - Body ground | Always | 10 kΩ or higher |
| C28-2 (+B) or 1B-4 - Body ground | Always | 10 kΩ or higher |
Reinstall the No. 1 integration relay.
Reconnect the heated oxygen sensor connector.
OK
NG