Home › Engine / Hybrid System › 1GD-FTV (ENGINE CONTROL) › ECD SYSTEM (w/ Urea SCR System) › 2015.06–2017.08
RM27T0E _51 Engine / Hybrid System _053660 1GD-FTV ENGINE CONTROL _0260461 ECD SYSTEM(w/ Urea SCR System) C

1GD-FTV ENGINE CONTROL  ECD SYSTEM(w/ Urea SCR System)  P205C  Reductant Tank Temperature Sensor Circuit Low  P205D  Reductant Tank Temperature Sensor Circuit High  


DESCRIPTION

Refer to DTC P202B (See page Engine / Hybrid System>1GD-FTV (ENGINE CONTROL)>ECD SYSTEM (w/ Urea SCR System)>P202B).

P205C
DTC Detection Drive Pattern DTC Detection Condition Trouble Area
Engine switch on (IG) and wait for 10 seconds or more. An open or short circuit occurs in the temperature sensor circuit for 10 seconds or more.
(1 trip detection logic)
·

Open or short in temperature sensor circuit

·

Temperature sensor (Urea Pump)

·

Urea pump control ECU



P205D
DTC Detection Drive Pattern DTC Detection Condition Trouble Area
Engine switch on (IG) and wait for 10 seconds or more. An open or short circuit occurs in the temperature sensor circuit for 10 seconds or more.
(1 trip detection logic)
·

Open or short in temperature sensor circuit

·

Temperature sensor (Urea Pump)

·

Urea pump control ECU



Related Data List
DTC No. Data List
P205C
P205D
Reductant Temperature

MONITOR DESCRIPTION

The urea pump control ECU calculates the temperature of the urea solution based on the output voltage of the temperature sensor. When the temperature sensor output voltage is outside the normal range, there may be a malfunction, short or open circuit in the temperature sensor. In this case, the urea pump control ECU determines that there is a malfunction in the temperature sensor, and then illuminates the MIL and stores a DTC through the ECM.

WIRING DIAGRAM

A357974E02
2.041,1.695 2.487,1.864 0.446,0.170 10 1 2.037,2.302 2.484,2.472 0.446,0.170 10 2 5.098,1.695 5.351,1.864 0.253,0.170 10 54 5.106,2.302 5.349,2.472 0.243,0.170 10 53 5.413,1.441 5.878,1.611 0.466,0.170 10 THU 5.413,2.042 5.878,2.212 0.466,0.170 10 ETHU 1.607,1.441 2.072,1.611 0.466,0.170 10 TUW 1.513,1.979 1.979,2.149 0.466,0.170 10 ETUW 0.569,2.777 0.840,2.947 0.270,0.170 10 s2 0.569,2.931 2.900,3.101 2.331,0.170 10 Temperature Sensor (Urea Pump) 5.39,3.116 5.660,3.285 0.270,0.170 10 s3 5.39,3.27 7.128,3.439 1.738,0.170 10 Urea Pump Control ECU

CAUTION / NOTICE / HINT

HINT:

Read freeze frame data using the GTS. Freeze frame data records the engine condition when malfunctions are detected. When troubleshooting, freeze frame data can help determine if the vehicle was moving or stationary, if the engine was warmed up or not, and other data from the time the malfunction occurred.


PROCEDURE

1.READ VALUE USING GTS
a.

Connect the GTS to the DLC3.


b.

Turn the engine switch on (IG) and turn the GTS on.


c.

Enter the following menus: Powertrain / Engine and ECT / Reductant Temperature.


d.

Read the values.


Standard:

Reductant temperature is the same as the ambient temperature of urea tank assembly.


Result:
Result Proceed to
-40°C (-40°F) A
80°C (176°F) B


HINT:
·

When the GTS indicates -40°C (-40°F), there is a open circuit.

·

When the GTS indicates 80°C (176°F), there is a short circuit.




A

2.READ VALUE USING GTS (CHECK FOR OPEN IN WIRE HARNESS)

B

9.READ VALUE USING GTS (CHECK FOR SHORT IN WIRE HARNESS)
2.READ VALUE USING GTS (CHECK FOR OPEN IN WIRE HARNESS)
a.

Disconnect the urea pump connector.


U169581E01
1.131,0.349 1.340,0.518 0.209,0.170 10 *1 3.604,0.349 3.820,0.518 0.216,0.170 10 *2 4.918,0.349 5.128,0.518 0.210,0.170 10 *a 2.188,0.96 2.566,1.110 0.377,0.150 10 TUW 5.655,0.729 6.033,0.879 0.377,0.150 10 s2 2.188,1.773 2.788,1.923 0.600,0.150 10 ETUW 6.125,1.331 6.498,2.142 false 6.386,2.201 6.811,2.371 0.425,0.170 10 TUW 6.016,1.331 5.643,2.142 false 5.436,2.201 6.032,2.371 0.596,0.170 10 ETUW

Text in Illustration
*1 Temperature Sensor (Urea Pump) *2 Urea Pump Control ECU
*a Front view of wire harness connector
(to Urea Pump)
- -

b.

Connect terminals 1 (TUW) and 2 (ETUW) of the urea pump connector on the wire harness side.


c.

Connect the GTS to the DLC3.


d.

Turn the engine switch on (IG) and turn the GTS on.


e.

Enter the following menus: Powertrain / Engine and ECT / Data List / Reductant Temperature.


f.

Read the values.


OK:

80°C (176°F)



OK

3.REPLACE UREA PUMP

NG

6.CHECK HARNESS AND CONNECTOR (UREA PUMP - UREA PUMP CONTROL ECU)
3.REPLACE UREA PUMP

NEXT

4.CLEAR DTC
4.CLEAR DTC
a.

Connect the GTS to the DLC3.


b.

Turn the engine switch on (IG) and turn the GTS on.



d.

Turn the engine switch off and wait for 30 seconds or more.


e.

Read the DTCs.



NEXT

5.CHECK WHETHER DTC OUTPUT RECURS
5.CHECK WHETHER DTC OUTPUT RECURS
a.

Connect the GTS to the DLC3.


b.

Turn the GTS on.


c.

Turn the engine switch on (IG) and wait for 10 seconds or more.


d.

Enter the following menus: Powertrain / Engine and ECT / Trouble Codes.


e.

Confirm that the DTCs are not output again.



NEXT

END

6.CHECK HARNESS AND CONNECTOR (UREA PUMP - UREA PUMP CONTROL ECU)
U169578E02
2.094,0.771 1.823,1.385 false 5.521,1.146 5.854,1.448 false 2.198,0.771 2.469,1.375 false 5.448,1.146 5.01,1.438 false 1.646,1.417 2.156,1.625 0.51,0.208 10 false ETUW 2.333,1.417 2.844,1.625 0.51,0.208 10 false TUW 1.729,0.167 2.156,0.365 0.427,0.198 10 false s2 5.396,0.177 5.823,0.375 0.427,0.198 10 false s3 0.563,0.094 1.073,0.302 0.51,0.208 10 false *a 4.125,0.094 4.635,0.302 0.51,0.208 10 false *b 4.667,1.458 5.385,1.667 0.719,0.208 10 false 53 (ETHU) 5.625,1.458 6.313,1.667 0.688,0.208 10 false 54 (THU)

Text in Illustration
*a Front view of wire harness connector
(to Urea Pump)
*b Front view of wire harness connector
(to Urea Pump Control ECU)

a.

Disconnect the urea pump connector.


b.

Disconnect the urea pump control ECU connector.


c.

Measure the resistance according to the value(s) in the table below.


Standard Resistance::
Tester Connection Condition Specified Condition
s2-1 (TUW) - s3-54 (THU) Always Below 1 Ω
s2-2 (ETUW) - s3-53 (ETHU) Always Below 1 Ω



OK

7.REPLACE UREA PUMP CONTROL ECU

NG

8.REPAIR OR REPLACE HARNESS OR CONNECTOR
7.REPLACE UREA PUMP CONTROL ECU

NEXT

4.CLEAR DTC
8.REPAIR OR REPLACE HARNESS OR CONNECTOR
a.

Repair or replace the harness or connector.



NEXT

4.CLEAR DTC
9.READ VALUE USING GTS (CHECK FOR SHORT IN WIRE HARNESS)
a.

Disconnect the urea pump assembly connector.


A357975E01
0.745,0.04 0.930,0.210 0.185,0.170 10 *1 2.626,0.04 2.811,0.210 0.185,0.170 10 *2

b.

Connect the GTS to the DLC3.


c.

Turn the engine switch on (IG).


d.

Turn the GTS on.


e.

Enter the following menus: Powertrain / Engine and ECT / Data List / Reductant Temperature.


f.

Read the values.

OK:

-40°C (-40°F)



Text in Illustration
*1 Temperature Sensor (Urea Pump)
*2 Urea Pump Control ECU


OK

3.REPLACE UREA PUMP

NG

10.CHECK WIRE HARNESS AND CONNECTOR (UREA PUMP - UREA PUMP CONTROL ECU)
10.CHECK WIRE HARNESS AND CONNECTOR (UREA PUMP - UREA PUMP CONTROL ECU)
U169579E02
5.521,1.146 5.854,1.448 false 2.198,0.771 2.469,1.375 false 2.333,1.417 2.844,1.625 0.51,0.208 10 false TUW 1.729,0.167 2.156,0.365 0.427,0.198 10 false s2 5.396,0.167 5.823,0.365 0.427,0.198 10 false s3 0.563,0.094 1.073,0.302 0.51,0.208 10 false *a 4.125,0.094 4.635,0.302 0.51,0.208 10 false *b 5.938,1.427 6.625,1.635 0.688,0.208 10 false 54 (THU)

Text in Illustration
*a Front view of wire harness connector
(to Urea Pump)
*b Front view of wire harness connector
(to Urea Pump Control ECU)

a.

Disconnect the urea pump connector.


b.

Disconnect the urea pump control ECU connector.


c.

Measure the resistance according to the value(s) in the table below.


Standard Resistance::
Tester Connection Condition Specified Condition
s2-1 (TUW) and s3-54 (THU) - Body ground and other terminals Always 10 kΩ or higher



OK

7.REPLACE UREA PUMP CONTROL ECU

NG

8.REPAIR OR REPLACE HARNESS OR CONNECTOR