2011-2013 Land Cruiser · Service Manual Engine / Hybrid / EV System

Pre-heating Control Circuit

Circuit diagnosis · Vehicles built from Jan 2012

Versions by build date: Sep 2011 – Dec 2011 from Jan 2012

DESCRIPTION

The glow plug is mounted inside the engine combustion chamber. To ensure efficient engine starting with a cold engine, the ECM calculates a time interval of the current that needs to flow through the glow plug depending on the starting engine coolant temperature when the ignition switch is turned to ON. The ECM then turns on the glow plug relay and permits current to flow through the glow plug based on the ECM calculated time. The glow plug is then heated, and enhances fuel combustion with a cold engine.
This DTC will be stored if the glow plug or the circuit is open.
A154593E06

HINT:
  1. These troubleshooting procedures are for: 1) difficult engine starting in cold weather, and 2) difficulty driving/vehicle malfunctions in cold weather immediately after engine is started.
  2. After the engine is started, the ECM performs an "after-glow" for a certain period of time. In proportion to the actual engine coolant temperature, the time period varies. The after-glow reduces diesel engine knocking, white smoke emissions and engine noises when the engine is cold.

G038988E17

WIRING DIAGRAM

A182513E03

INSPECTION PROCEDURE

NOTICE:
After replacing the ECM, the new ECM needs registration (Click here) and initialization (Click here).


1. CHECK ECM TERMINAL VOLTAGE (GREL TERMINAL)

  1. A182516E01
    Remove the GLOW 1 relay from the engine room relay block.

  1. Remove the GLOW 2 relay from the engine room relay block.

  1. Measure the voltage according to the value(s) in the table below.

    Standard Voltage:
    Tester Connection
    Switch Condition
    Specified Condition
    GLOW 1 relay (2) - Body ground
    Ignition switch ON
    11 to 14 V
    GLOW 2 relay (2) - Body ground
    Ignition switch ON
    11 to 14 V



NG
Go to step 7
OK


2. INSPECT GLOW RELAY (GLOW 1 or 2)
  1. Inspect the GLOW 1 relay (Click here).

  1. Inspect the GLOW 2 relay (Click here).



NG
REPLACE GLOW RELAY (GLOW 1 or 2)
OK


3. INSPECT FUSE (GLOW 1 and GLOW 2)
A182514E01
  1. Remove the GLOW 1 and GLOW 2 fuses from the engine room relay block.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Component
    Condition
    Specified Condition
    GLOW 1 H-fuse
    Always
    Below 1 Ω
    GLOW 2 H-fuse
    Always
    Below 1 Ω



NG
CHECK FOR SHORT IN ALL HARNESSES AND COMPONENTS CONNECTED TO FUSE, AND REPLACE FUSE
OK


4. INSPECT GLOW PLUG ASSEMBLY (RESISTANCE)
  1. Inspect the glow plug assembly (Click here).



NG
REPLACE GLOW PLUG ASSEMBLY (Click here)
OK


5. CHECK GLOW PLUG ASSEMBLY (INSTALLATION)
  1. Check the glow plug installation (Click here).

    OK:
    Glow plugs are installed securely.



NG
TIGHTEN GLOW PLUG (Click here)
OK


6. CHECK HARNESS AND CONNECTOR (GLOW PLUG RELAY - GLOW PLUG - BATTERY AND BODY GROUND)

  1. A182515E01
    Remove the GLOW 1 relay from the engine room relay block.

  1. Disconnect the C77 glow plug connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance (Check for Open):
    No. 1 
    Tester Connection
    Condition
    Specified Condition
    GLOW 1 relay (3) - C77-1
    Always
    Below 1 Ω
    GLOW 1 relay (5) - Positive (+) battery terminal cable
    Always
    Below 1 Ω
    GLOW 1 relay (1) - Body ground
    Always
    Below 1 Ω

  1. Remove the GLOW 2 relay from the engine room relay block.

  1. Disconnect the C78 glow plug connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance (Check for Open):
    No. 2 
    Tester Connection
    Condition
    Specified Condition
    GLOW 2 relay (3) - C78-1
    Always
    Below 1 Ω
    GLOW 2 relay (5) - Positive (+) battery terminal cable
    Always
    Below 1 Ω
    GLOW 2 relay (1) - Body ground
    Always
    Below 1 Ω



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

CHECK FOR INTERMITTENT PROBLEMS (Click here)

7. CHECK HARNESS AND CONNECTOR (GLOW PLUG RELAY - ECM AND BODY GROUND)

  1. A182517E01
    Remove the GLOW 1 relay from the engine room relay block.

  1. Remove the GLOW 2 relay from the engine room relay block.

  1. Disconnect the ECM connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance (Check for Open):
    for LHD 
    Tester Connection
    Condition
    Specified Condition
    GLOW 1 relay (2) - C45-63 (GREL)
    Always
    Below 1 Ω
    GLOW 2 relay (2) - C45-62 (GRL2)
    Always
    Below 1 Ω
    for RHD 
    Tester Connection
    Condition
    Specified Condition
    GLOW 1 relay (2) - C46-63 (GREL)
    Always
    Below 1 Ω
    GLOW 2 relay (2) - C46-62 (GRL2)
    Always
    Below 1 Ω


    Standard Resistance (Check for Short):
    for LHD 
    Tester Connection
    Condition
    Specified Condition
    GLOW 1 relay (2) or C45-63 (GREL) - Body ground
    Always
    10 kΩ or higher
    GLOW 2 relay (2) or C45-62 (GRL2) - Body ground
    Always
    10 kΩ or higher
    for RHD 
    Tester Connection
    Condition
    Specified Condition
    GLOW 1 relay (2) or C46-63 (GREL) - Body ground
    Always
    10 kΩ or higher
    GLOW 2 relay (2) or C46-62 (GRL2) - Body ground
    Always
    10 kΩ or higher



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE ECM (Click here)


← Pre-heating Control Circuit (Sep 2011 – Dec 2011)Rough Idling or Excessive Engine Vibrations (Sep 2011 – Dec 2011) →