2011-2013 Land Cruiser · Service Manual Engine / Hybrid / EV System

P0136 Oxygen Sensor Circuit Malfunction (Bank 1 Sensor 2)

Diagnostic trouble codes · Vehicles built Sep 2011 – Dec 2011

Also covers:

Versions by build date: Sep 2011 – Dec 2011 from Jan 2012

DESCRIPTION

HINT:
Sensor 2 refers to the sensor mounted behind the three-way catalytic converter and located far from the engine assembly.

A three-way catalyst converter is used in order to convert the carbon monoxide, hydrocarbons, and nitrogen oxide, into less harmful substances. To allow the three-way catalytic converter to function effectively, it is necessary to keep the air fuel ratio of the engine near the stoichiometric air fuel ratio. For the purpose of helping the ECM to deliver accurate air fuel ratio control, a heated oxygen sensor is used.
The heated oxygen sensor is located behind the three-way catalytic converter, and detects the oxygen concentration in the exhaust gas. Since the sensor is integrated with the heater that heats the sensing portion, it is possible to detect the oxygen concentration even when the intake air volume is low (the exhaust gas temperature is low).
When the air fuel ratio becomes lean, the oxygen concentration in the exhaust gas is rich. The heated oxygen sensor informs the ECM that the post-three way catalytic converter air fuel ratio is lean (low voltage, i.e. below 0.45 V).
Conversely, when the air fuel ratio is richer than the stoichiometric air fuel level, the oxygen concentration in the exhaust gas becomes lean. The heated oxygen sensor informs the ECM that the post-three way catalytic converter air fuel ratio is rich (high voltage, i.e. higher than 0.45 V). The heated oxygen sensor has the property of changing its output voltage drastically when the air fuel ratio is close to the stoichiometric level.
The ECM uses the supplementary information from the heated oxygen sensor to determine whether the air fuel ratio after the three-way catalytic converter is rich or lean, and adjusts the fuel injection time accordingly. Thus, if the heated oxygen sensor is working improperly due to internal malfunctions, the ECM is unable to compensate for deviations in the primary air fuel ratio control.
A208686E01
DTC Code
DTC Detection Condition
Trouble Area
P0136
P0156
  1. Abnormal voltage output:
    During active air fuel ratio control, the following conditions (a) and (b) are met for a certain period of time (2 trip detection logic):
    1. The heated oxygen sensor voltage does not decrease to below 0.21 V.
    2. The heated oxygen sensor voltage does not increase to higher than 0.59 V.
  1. Open or short in HO2 sensor (bank 1, 2 sensor 2) circuit
  2. HO2 sensor (bank 1, 2 sensor 2)
  3. HO2 sensor heater (bank 1, 2 sensor 2)
  4. Air fuel ratio (A/F) sensor (bank 1, 2 sensor 1)
  5. Gas leak from exhaust system
P0137
P0157
  1. Low voltage (open):
    During active air fuel ratio control, the following conditions (a) and (b) are met for a certain period of time (2 trip detection logic):
    1. The heated oxygen sensor voltage output is below 0.21 V.
    2. The target air fuel ratio is rich.
  1. Open in HO2 sensor (bank 1, 2 sensor 2) circuit
  2. HO2 sensor (bank 1, 2 sensor 2)
  3. HO2 sensor heater (bank 1, 2 sensor 2)
  4. Gas leak from exhaust system
P0138
P0158
  1. High voltage (short):
    During active air fuel ratio control, the following conditions (a) and (b) are met for a certain period of time (2 trip detection logic):
    1. The heated oxygen sensor voltage output is 0.59 V or higher.
    2. The target air fuel ratio is lean.
  1. Short in HO2 sensor (bank 1, 2 sensor 2) circuit
  2. HO2 sensor (bank 1, 2 sensor 2)
  3. A/F sensor (bank 1, 2 sensor 1)
  4. ECM

WIRING DIAGRAM

A182258E03

CONFIRMATION DRIVING PATTERN

A199376E95
  1. Connect the intelligent tester to the DLC3 [A].
  2. Turn the tester on.
  3. Warm up the engine until the engine coolant temperature is 75°C (167°F) or higher [B].
  4. Drive the vehicle at 60 to 120 km/h (38 to 75 mph) for at least 10 minutes [C].
  5. Enter the following menus: Powertrain / Engine / Utility / All Readiness [D].
  6. Input DTCs: P0136, P0137, P0138, P0156, P0157 and P0158.
  7. Check that DTC MONITOR is NORMAL. If DTC MONITOR is INCOMPLETE, perform the drive pattern again by accelerating the vehicle and using the second gear to decelerate the vehicle.

INSPECTION PROCEDURE

HINT:
Malfunctioning areas can be identified by performing the Control the Injection Volume for A/F sensor function provided in the Active Test. The Control the Injection Volume for A/F sensor function can help to determine whether the Air Fuel Ratio (A/F) sensor, Heated Oxygen (HO2) sensor and other potential trouble areas are malfunctioning.
The following instructions describe how to conduct the Control the Injection Volume for A/F sensor operation using the intelligent tester.
  1. Connect the intelligent tester to the DLC3.
  2. Start the engine and turn the intelligent tester on.
  3. Warm up the engine at an engine speed of 2500 rpm for approximately 90 seconds.
  4. Enter the following menus: Powertrain / Engine and ECT / Active Test / Control the Injection Volume for A/F sensor.
  5. Perform the Active Test operation with the engine idling (press the RIGHT or LEFT button to change the fuel injection volume).
  6. Monitor the output voltages of the A/F and HO2 sensors (AFS Voltage B1S1 and O2S B1S2, or AFS Voltage B2S1 and O2S B2S2) displayed on the intelligent tester.

HINT:
  1. The Control the Injection Volume for A/F sensor operation lowers the fuel injection volume by 12.5% or increases the injection volume by 25%.
  2. Each sensor reacts in accordance with increases and decreases in the fuel injection volume.

Tester Display (Sensor)
Injection Volume
Status
Voltage
AFS Voltage B1S1 or AFS Voltage B2S1
(A/F)
+25%
Rich
Less than 3.1 V
AFS Voltage B1S1 or AFS Voltage B2S1
(A/F)
-12.5%
Lean
More than 3.4 V
O2S B1S2 or O2S B2S2
(HO2)
+25%
Rich
More than 0.55 V
O2S B1S2 or O2S B2S2
(HO2)
-12.5%
Lean
Less than 0.4 V

NOTICE:
The Air Fuel Ratio (A/F) sensor has an output delay of a few seconds and the Heated Oxygen (HO2) sensor has a maximum output delay of approximately 20 seconds.

Case
A/F Sensor (Sensor 1) Output Voltage
HO2 Sensor (Sensor 2) Output Voltage
Main Suspected Trouble Area
1
A150787E01
A151324E05
A150787E01
A150788E01
-
2
A150787E01
A150790E01
A150787E01
A150788E01
  1. A/F sensor
  2. A/F sensor heater
  3. A/F sensor circuit
3
A150787E01
A151324E05
A150787E01
A150790E01
  1. HO2 sensor
  2. HO2 sensor heater
  3. HO2 sensor circuit
4
A150787E01
A150790E01
A150787E01
A150790E01
  1. Injector
  2. Fuel pressure
  3. Gas leakage from exhaust system (Air fuel ratio extremely rich or lean)
  1. Following the Control the Injection Volume for A/F sensor procedure enables technicians to check and graph the voltage outputs of both the A/F and HO2 sensors.
  2. To display the graph, enter the following menus: Powertrain / Engine and ECT / Active Test / Control the Injection Volume for A/F Sensor / A/F Control System / AFS Voltage B1S1 and O2S B1S2 or AFS Voltage B2S1 and O2S B2S2.

HINT:
Read freeze frame data using the intelligent tester. Freeze frame data records the engine condition when malfunctions are detected. When troubleshooting, freeze frame data can help determine if the vehicle was moving or stationary, if the engine was warmed up or not, if the air fuel ratio was lean or rich, and other data from the time the malfunction occurred.


1. READ OUTPUT DTC (DTC P0136, P0137, P0138, P0156, P0157 OR P0158)
  1. Connect an intelligent tester to the DLC3.

  1. Turn the ignition switch to ON.

  1. Turn the tester on.

  1. Enter the following menus: Powertrain / Engine and ECT / DTC.

  1. Read DTCs.

    Result 
    Result
    Proceed to
    P0138 or P0158
    A
    P0137 or P0157
    B
    P0136 or P0156
    C



B
Go to step 9

C
Go to step 7
A


2. READ VALUE USING INTELLIGENT TESTER (OUTPUT VOLTAGE OF HEATED OXYGEN SENSOR)
  1. Connect an intelligent tester to the DLC3.

  1. Turn the ignition switch to ON.

  1. Turn the tester on.

  1. Enter the following menus: Powertrain / Engine and ECT / Data List / A/F Control System / O2S B1S2.

  1. Allow the engine to idle.

  1. Read the heated oxygen sensor output voltage while idling.

    Result:
    Result
    Proceed to
    Higher than 1.0 V
    A
    Below 1.0 V
    B



B
Go to step 5
A


3. INSPECT HEATED OXYGEN SENSOR (CHECK FOR SHORT)

  1. A117841E37
    Disconnect the heated oxygen sensor connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance (Bank 1 Sensor 2):
    Tester Connection
    Condition
    Specified Condition
    2 (+B) - 4 (E2)
    20°C (68°F)
    10 kΩ or higher
    2 (+B) - 3 (OX1B)
    Always
    10 kΩ or higher

    Standard Resistance (Bank 2 Sensor 2):
    Tester Connection
    Condition
    Specified Condition
    2 (+B) - 4 (E2)
    20°C (68°F)
    10 kΩ or higher
    2 (+B) - 3 (OX2B)
    Always
    10 kΩ or higher



NG
REPLACE HEATED OXYGEN SENSOR (Click here)
OK


4. CHECK HARNESS AND CONNECTOR (CHECK FOR SHORT)

  1. A136305E99
    Disconnect the ECM connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    for LHD 
    Tester Connection
    Condition
    Specified Condition
    C45-48 (HT1B) - C45-88 (OX1B)
    Always
    10 kΩ or higher
    C45-47 (HT2B) - C45-87 (OX2B)
    Always
    10 kΩ or higher
    for RHD 
    Tester Connection
    Condition
    Specified Condition
    C46-48 (HT1B) - C46-88 (OX1B)
    Always
    10 kΩ or higher
    C46-47 (HT2B) - C46-87 (OX2B)
    Always
    10 kΩ or higher



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR (ECM - HEATED OXYGEN SENSOR)
OK

REPLACE ECM (Click here)

5. PERFORM ACTIVE TEST USING INTELLIGENT TESTER (INJECTION VOLUME)
  1. Connect the intelligent tester to the DLC3.

  1. Start the engine.

  1. Turn the tester on.

  1. Warm up the engine.

  1. Enter the following menus: Powertrain / Engine / Active Test / Control the Injection Volume.

  1. Change the fuel injection volume using the tester, and monitor the voltage output of the air fuel ratio sensor and heated oxygen sensor displayed on the tester.

    HINT:
    1. Change the fuel injection volume within the range of -12% and +12%. The injection volume can be changed in 1% graduations within this range.
    2. The air fuel ratio sensor is displayed as AFS Voltage B1S1, and the heated oxygen sensor is displayed as O2S B1S2 on the intelligent tester.


    Result:
    Tester Display (Sensor)
    Voltage Variation
    Proceed to
    AFS Voltage B1S1 (A/F)
    Alternates between higher than and below 3.3 V
    OK
    AFS Voltage B1S1 (A/F)
    Remains at higher than 3.3 V
    NG
    AFS Voltage B1S1 (A/F)
    Remains at below 3.3 V
    NG

    HINT:
    A normal heated oxygen sensor voltage (O2S B1S2) reacts in accordance with increases and decreases in fuel injection volumes. When the air fuel ratio sensor voltage remains at either less or higher than 3.3 V despite the heated oxygen sensor indicating a normal reaction, the air fuel ratio sensor is malfunctioning.

    A121606E04



NG
Go to step 15
OK


6. CHECK AIR FUEL RATIO SENSOR

HINT:
This air fuel ratio sensor test is to check the air fuel ratio sensor current during the fuel-cut operation. When the sensor is normal, the sensor current will indicate below 3 mA in this test.

  1. Connect an intelligent tester to the DLC3.

  1. Turn the ignition switch to ON.

  1. Turn the tester on.

  1. Enter the following menus: Powertrain / Engine and ECT / DTC / Clear.

  1. Clear DTCs.

  1. Drive the vehicle by the drive pattern as listed below:

    1. Warm up the engine.

    2. Drive the vehicle at 60 km/h (40 mph) or more for 10 minutes or more.

    3. Stop the vehicle.

    4. Accelerate the vehicle to 60 km/h (40 mph) or more and then decelerate for 5 seconds or more. Repeat this process at least 3 times.A152792E04

  1. Enter the following menus: Powertrain / Engine and ECT / Data List / A/F Control System / AFS Current B1S1.

  1. Read the value of the air fuel ratio sensor current while the fuel-cut operation is performing.

    Standard current:
    Below 3.0 mA

    HINT:
    1. To measure the air fuel ratio sensor current precisely, perform the fuel-cut operation as long as possible.
    2. If it is difficult to measure the air fuel ratio sensor current, use the snapshot function of the intelligent tester.

Result 
Result
Proceed to
Outside standard range
A
Within standard range
B


OK
Go to step 12

NG
Go to step 15
7. READ VALUE USING INTELLIGENT TESTER (OUTPUT VOLTAGE OF HEATED OXYGEN SENSOR)
  1. Connect the intelligent tester to the DLC3.

  1. Turn the ignition switch to ON.

  1. Turn the tester on.

  1. Start the engine.

  1. Enter the following menus: Powertrain / Engine and ECT / Data List / A/F Control System / O2S B1S2.

  1. After warming up the engine, run the engine at an engine speed of 2500 rpm for 3 minutes.

  1. Read the output voltage of the heated oxygen sensor when the engine speed is suddenly increased.

    HINT:
    Quickly accelerate the engine to 4000 rpm 3 times using the accelerator pedal.

    Standard voltage:
    Fluctuates between 0.4 V or less and 0.55 V or higher.



NG
Go to step 9
OK


8. PERFORM ACTIVE TEST USING INTELLIGENT TESTER (INJECTION VOLUME)
  1. Connect the intelligent tester to the DLC3.

  1. Start the engine.

  1. Turn the tester on.

  1. Warm up the engine.

  1. Enter the following menus: Powertrain / Engine / Active Test / Control the Injection Volume.

  1. Change the fuel injection volume using the tester, and monitor the voltage output of the air fuel ratio sensor and heated oxygen sensor displayed on the tester.

    HINT:
    1. Change the fuel injection volume within the range of -12% and +12%. The injection volume can be changed in 1% graduations within this range.
    2. The air fuel ratio sensor is displayed as AFS Voltage B1S1, and the heated oxygen sensor is displayed as O2S B1S2 on the intelligent tester.


    Result:
    Tester Display (Sensor)
    Voltage Variation
    Proceed to
    AFS Voltage B1S1 (A/F)
    Alternates between higher than and below 3.3 V
    OK
    AFS Voltage B1S1 (A/F)
    Remains at higher than 3.3 V
    NG
    AFS Voltage B1S1 (A/F)
    Remains at below 3.3 V
    NG

    HINT:
    A normal heated oxygen sensor voltage (O2S B1S2) reacts in accordance with increases and decreases in fuel injection volumes. When the air fuel ratio sensor voltage remains at either less or higher than 3.3 V despite the heated oxygen sensor indicating a normal reaction, the air fuel ratio sensor is malfunctioning.

    A121606E04



NG
Go to step 15
OK

CHECK EXTREMELY RICH OR LEAN ACTUAL AIR FUEL RATIO AND REPAIR CAUSE (FUEL INJECTOR , FUEL PRESSURE, GAS LEAK FROM SYSTEM, ETC.)

9. CHECK FOR EXHAUST GAS LEAK
  1. Check for exhaust gas leakage.

    OK:
    No gas leak.



NG
REPAIR OR REPLACE EXHAUST GAS LEAK POINT
OK


10. INSPECT HEATED OXYGEN SENSOR (HEATER RESISTANCE)

  1. A117841E37
    Disconnect the heated oxygen sensor connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    1 (HT1B) - 2 (+B)
    20°C (68°F)
    11 to 16 Ω
    1 (HT1B) - 4 (E2)
    Always
    10 kΩ or higher



NG
REPLACE HEATED OXYGEN SENSOR (Click here)
OK


11. CHECK HARNESS AND CONNECTOR (HEATED OXYGEN SENSOR - ECM)

  1. A182249E02
    Disconnect the heated oxygen sensor connector.

  1. Disconnect the ECM connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance (Check for Open):
    for LHD 
    Tester Connection
    Condition
    Specified Condition
    C20-1 (HT1B) - C45-48 (HT1B)
    Always
    Below 1 Ω
    C20-3 (OX1B) - C45-88 (OX1B)
    Always
    Below 1 Ω
    C20-4 (E2) - C45-65 (EX1B)
    Always
    Below 1 Ω
    C21-1 (HT2B) - C45-47 (HT2B)
    Always
    Below 1 Ω
    C21-3 (OX2B) - C45-87 (OX2B)
    Always
    Below 1 Ω
    C21-4 (E2) - C45-64 (EX2B)
    Always
    Below 1 Ω
    for RHD 
    Tester Connection
    Condition
    Specified Condition
    C20-1 (HT1B) - C46-48 (HT1B)
    Always
    Below 1 Ω
    C20-3 (OX1B) - C46-88 (OX1B)
    Always
    Below 1 Ω
    C20-4 (E2) - C46-65 (EX1B)
    Always
    Below 1 Ω
    C21-1 (HT2B) - C46-47 (HT2B)
    Always
    Below 1 Ω
    C21-3 (OX2B) - C46-87 (OX2B)
    Always
    Below 1 Ω
    C21-4 (E2) - C46-64 (EX2B)
    Always
    Below 1 Ω


    Standard Resistance (Check for Short):
    for LHD 
    Tester Connection
    Condition
    Specified Condition
    C20-1 (HT1B) or C45-48 (HT1B) - Body ground
    Always
    10 kΩ or higher
    C20-3 (OX1B) or C45-88 (OX1B) - Body ground
    Always
    10 kΩ or higher
    C20-4 (E2) or C45-65 (EX1B) - Body ground
    Always
    10 kΩ or higher
    C21-1 (HT2B) or C45-47 (HT2B) - Body ground
    Always
    10 kΩ or higher
    C21-3 (OX2B) or C45-87 (OX2B) - Body ground
    Always
    10 kΩ or higher
    C21-4 (E2) or C45-64 (EX2B) - Body ground
    Always
    10 kΩ or higher
    for RHD 
    Tester Connection
    Condition
    Specified Condition
    C20-1 (HT1B) or C46-48 (HT1B) - Body ground
    Always
    10 kΩ or higher
    C20-3 (OX1B) or C46-88 (OX1B) - Body ground
    Always
    10 kΩ or higher
    C20-4 (E2) or C46-65 (EX1B) - Body ground
    Always
    10 kΩ or higher
    C21-1 (HT2B) or C46-47 (HT2B) - Body ground
    Always
    10 kΩ or higher
    C21-3 (OX2B) or C46-87 (OX2B) - Body ground
    Always
    10 kΩ or higher
    C21-4 (E2) or C46-64 (EX2B) - Body ground
    Always
    10 kΩ or higher

A182248E02


NG
REPAIR OR REPLACE HARNESS OR CONNECTOR (ECM - HEATED OXYGEN SENSOR)
OK


12. REPLACE HEATED OXYGEN SENSOR
  1. Replace the heated oxygen sensor (Click here).


NEXT


13. PERFORM CONFIRMATION DRIVING PATTERN

HINT:
Refer to the CONFIRMATION DRIVING PATTERN.


NEXT


14. CHECK WHETHER DTC OUTPUT RECURS (DTC P0136, P0137, P0138, P0156, P0157 OR P0158)
  1. Connect an intelligent tester to the DLC3.

  1. Turn the ignition switch to ON.

  1. Turn the tester on.

  1. Enter the following menus: Powertrain / Engine and ECT / Utility / All Readiness.

  1. Input DTCs: P0136, P0137, P0138, P0156, P0157 and P0158.

  1. Check the DTC monitor is NORMAL. If DTC monitor is INCOMPLETE, perform the drive pattern again by accelerating the vehicle and using the second gear to decelerate the vehicle.

    Result 
    Result
    Proceed to
    NORMAL
    (No DTC output)
    A
    ABNORMAL
    (P0136, P0137, P0138, P0156, P0157 or P0158 detected)
    B



B
REPLACE AIR FUEL RATIO SENSOR (Click here)
A

END

15. REPLACE AIR FUEL RATIO SENSOR
  1. Replace the air fuel ratio sensor (Click here).


NEXT


16. PERFORM CONFIRMATION DRIVING PATTERN

HINT:
Refer to the CONFIRMATION DRIVING PATTERN.


NEXT


17. CHECK WHETHER DTC OUTPUT RECURS (DTC P0136, P0137, P0138, P0156, P0157 OR P0158)
  1. Connect an intelligent tester to the DLC3.

  1. Turn the ignition switch to ON.

  1. Turn the tester on.

  1. Enter the following menus: Powertrain / Engine and ECT / Utility / All Readiness.

  1. Input DTCs: P0136, P0137, P0138, P0156, P0157 and P0158.

  1. Check the DTC monitor is NORMAL. If DTC monitor is INCOMPLETE, perform the drive pattern again by accelerating the vehicle and using the second gear to decelerate the vehicle.

    Result 
    Result
    Proceed to
    NORMAL
    (No DTC output)
    A
    ABNORMAL
    (P0136, P0137, P0138, P0156, P0157 or P0158 detected)
    B



B
REPLACE HEATED OXYGEN SENSOR (Click here)
A

END


← P0120 Throttle / Pedal Position Sensor / Switch "A" Circuit Malfunction (+ 7 more codes) (from Jan 2012)P0136 Oxygen Sensor Circuit Malfunction (Bank 1 Sensor 2) (+ 5 more codes) (from Jan 2012) →