B1412 Ambient Temperature Sensor Circuit
Diagnostic trouble codes · Vehicles built Sep 2011 – Dec 2011
Versions by build date: Sep 2011 – Dec 2011 from Jan 2012
DESCRIPTION
The cooler thermistor (ambient temperature sensor) is installed in the front part of the cooler condenser assembly. This sensor is connected to the air conditioning amplifier assembly and detects fluctuations in the ambient temperature. The sensor sends a signal to the air conditioning amplifier assembly. The resistance of the cooler thermistor (ambient temperature sensor) changes in accordance with the ambient temperature. As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases.The air conditioning amplifier assembly applies a voltage (5 V) to the cooler thermistor (ambient temperature sensor) and reads voltage changes as changes in the resistance of the cooler thermistor (ambient temperature sensor).
| DTC Code |
DTC Detection Condition |
Trouble Area |
| B1412 |
An open or short in the cooler thermistor (ambient temperature sensor) circuit is detected for 8.5 minutes or more. |
|
WIRING DIAGRAM


INSPECTION PROCEDURE
| 1. READ VALUE USING INTELLIGENT TESTER (AMBIENT TEMP SENSOR) |
Use the Data List to check if the cooler thermistor (ambient temperature sensor) is functioning properly (Click here).
Air Conditioner Tester Display
Measurement Item/Range
Normal Condition
Diagnostic Note
Ambient Temp Sensor
Cooler thermistor (ambient temperature sensor) /
Min: -23.3°C (-9.94°F)
Max: 65.95°C (150.71°F)
Actual ambient temperature displayed
Open in the circuit: -23.3°C (-9.94°F).
Short in the circuit: 65.95°C (150.71°F).
- OK:
- The display is as specified in the normal condition column.
Result Result
Proceed to
OK (When troubleshooting according to problem symptoms table)
A
OK (When troubleshooting according to the DTC)
B
NG
C
|
|
||||
|
|
||||
| A | ||
| ||
| 2. INSPECT COOLER THERMISTOR (AMBIENT TEMPERATURE SENSOR) |
Remove the cooler thermistor (ambient temperature sensor) (Click here).

Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Condition
Specified Condition
1 - 2
10°C (50°F)
3.00 to 3.73 kΩ
15°C (59°F)
2.45 to 2.88 kΩ
20°C (68°F)
1.95 to 2.30 kΩ
25°C (77°F)
1.60 to 1.80 kΩ
30°C (86°F)
1.28 to 1.47 kΩ
35°C (95°F)
1.00 to 1.22 kΩ
40°C (104°F)
0.80 to 1.00 kΩ
45°C (113°F)
0.65 to 0.85 kΩ
50°C (122°F)
0.50 to 0.70 kΩ
55°C (131°F)
0.44 to 0.60 kΩ
60°C (140°F)
0.36 to 0.50 kΩ
Text in Illustration *a
Sensing Portion
*b
Resistance
*c
Allowable Range
*d
Temperature
- NOTICE:
- Even slightly touching the sensor may change the resistance value. Be sure to hold the connector of the sensor.
- When measuring, the sensor temperature must be the same as the ambient temperature.
- Even slightly touching the sensor may change the resistance value. Be sure to hold the connector of the sensor.
- HINT:
- As the temperature increases, the resistance decreases (refer to the graph).
|
|
||||
| OK | |
| 3. CHECK HARNESS AND CONNECTOR (COOLER THERMISTOR - AIR CONDITIONING AMPLIFIER) |
Disconnect the A14 cooler thermistor (ambient temperature sensor) connector.
Disconnect the E81 air conditioning amplifier assembly connector.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Condition
Specified Condition
A14-1 - E81-5 (TAM)
Always
Below 1 Ω
A14-2 - E81-13 (SG-2)
E81-5 (TAM) - Body ground
Always
10 kΩ or higher
E81-13 (SG-2) - Body ground
|
|
||||
| OK | ||
| ||