Entire Combination Meter does not Operate
Circuit diagnosis · Vehicles built from Sep 2011
DESCRIPTION
This circuit is the power source circuit for the combination meter. This circuit provides 2 power source types: one is a constant power source mainly used as a backup power source, and the other is a power source mainly used for signal transmission. The constant power source is mainly used as a backup power source for the meter CPU. However, it is also used for communication. If a voltage of 12 V is not applied to terminal IG+ when the ignition switch isON, indicators will not operate.WIRING DIAGRAM


INSPECTION PROCEDURE
| 1. INSPECT FUSE (MET, ECU-B1) |
Remove the MET and ECU-B1 fuses from the engine room relay block.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Condition
Specified Condition
MET fuse
Always
Below 1 Ω
ECU-B1 fuse
|
|
||||
| OK | |
| 2. CHECK HARNESS AND CONNECTOR (COMBINATION METER ASSEMBLY - BATTERY AND BODY GROUND) |
![]() ![]() |
Disconnect the E7 meter connector.
Measure the resistance and voltage according to the value(s) in the tables below.
- Standard Resistance:
Tester Connection
Condition
Specified Condition
E7-15 (ET) - Body ground
Always
Below 1 Ω
- Standard Voltage:
Tester Connection
Switch Condition
Specified Condition
E7-17 (B) - Body ground
Always
11 to 14 V
E7-18 (IG+) - Body ground
Ignition switch ON
| Result |
Proceed to |
| NG |
A |
| OK (w/ Multi-information Display) |
B |
| OK (w/o Multi-information Display) |
C |
|
|
||||
|
|
||||
| A | ||
| ||