B1417/17 Rear Evaporator Temperature Sensor Circuit
Diagnostic trouble codes · Vehicles built Sep 2011 – Dec 2011
Versions by build date: Sep 2011 – Dec 2011 from Jan 2012
DESCRIPTION
The No. 2 cooler thermistor is installed on the evaporator in the rear air conditioning unit to detect the cooled air temperature that has passed through the evaporator and control the air conditioning. It sends appropriate signals to the air conditioning amplifier assembly. The resistance of the No. 2 cooler thermistor changes in accordance with the cooled air temperature that has passed through the rear evaporator. As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases.The air conditioning amplifier assembly applies voltage (5 V) to the No. 2 cooler thermistor and reads voltage changes as the resistance of the No. 2 cooler thermistor changes. This sensor is used for frost prevention.
| DTC Code |
DTC Detection Condition |
Trouble Area |
| B1417/17 |
An open or short in the No. 2 cooler thermistor circuit. |
|
WIRING DIAGRAM


INSPECTION PROCEDURE
| 1. READ VALUE USING INTELLIGENT TESTER (NO. 2 COOLER THERMISTOR) |
Use the Data List to check if the No. 2 cooler thermistor is functioning properly.
Air Conditioner Tester Display
Measurement Item/Range
Normal Condition
Diagnostic Note
Ambient Temp Sens (Rear)
No. 2 cooler thermistor /
Min.: -29.7°C (-21.46°F)
Max.: 59.55°C (139.19°F)
Actual rear evaporator temperature displayed
Open in the circuit: -29.7°C (-21.46°F).
Short in the circuit: 59.55°C (139.19°F).
- OK:
- The display is as specified in the normal condition.
|
|
||||
| OK | ||
| ||
| 2. INSPECT NO. 2 COOLER THERMISTOR |
![]() ![]() |
Remove the No. 2 air conditioning harness assembly (Click here).
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Condition
Specified Condition
7 (-) - 8 (+)
-10°C (14°F)
7.40 to 9.20 kΩ
-5°C (23°F)
5.65 to 7.00 kΩ
0°C (32°F)
4.35 to 5.40 kΩ
5°C (41°F)
3.40 to 4.20 kΩ
10°C (50°F)
2.68 to 3.30 kΩ
15°C (59°F)
2.10 to 2.60 kΩ
20°C (68°F)
1.66 to 2.10 kΩ
25°C (77°F)
1.32 to 1.66 kΩ
30°C (86°F)
1.05 to 1.35 kΩ
- NOTICE:
- Even slightly touching the sensor may change the resistance value. Be sure to hold the connector of the sensor.
- When measuring, the sensor temperature must be the same as the ambient temperature.
- Even slightly touching the sensor may change the resistance value. Be sure to hold the connector of the sensor.
- HINT:
- As the temperature increases, the resistance decreases (see the graph).
|
|
||||
| OK | |
| 3. CHECK HARNESS AND CONNECTOR (NO. 2 AIR CONDITIONING HARNESS - AIR CONDITIONING AMPLIFIER) |
![]() ![]() |
Disconnect the K19 No. 2 air conditioning harness connector.
Disconnect the E35 amplifier connector.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Condition
Specified Condition
K19-8 (+) - E35-17 (TEC)
Always
Below 1 Ω
K19-7 (-) - E35-1 (SG)
Always
Below 1 Ω
E35-17 (TEC) - Body ground
Always
10 kΩ or higher
E35-1 (SG) - Body ground
Always
10 kΩ or higher
|
|
||||
| OK | |
| 4. CHECK NO. 2 AIR CONDITIONING HARNESS ASSEMBLY (OPERATION) |
Replace the No. 2 air conditioning harness assembly with a normal one and check that the condition returns to normal (Click here).
| NEXT | |
| 5. CHECK FOR DTC |
Clear the DTCs (Click here).
Check for DTCs (Click here).
- OK:
- DTC B1417 is not output.
|
|
||||
| OK | ||
| ||


