Home › Engine / Hybrid System › 1UR-FE (ENGINE CONTROL) › HEATED OXYGEN SENSOR › from 2015.08
RM2660E _51 Engine / Hybrid System _052772 1UR-FE ENGINE CONTROL _0254980 HEATED OXYGEN SENSOR A

1UR-FE ENGINE CONTROL  HEATED OXYGEN SENSOR  INSTALLATION  


PROCEDURE

Hide 89465 1.INSTALL HEATED OXYGEN SENSOR (for Bank 2 Sensor 2)

a.

Temporarily install the sensor to the front exhaust pipe by hand.


b.
U163329E01
0.594,1.577 0.754,1.726 0.161,0.149 10 *1 2.561,0.608 2.866,0.758 0.305,0.150 10 SST 1.945,0.393 2.456,0.691 2.456,0.691 2.555,0.691 false

Using SST, tighten the heated oxygen sensor.

SST
09224-00010  

Torque:
without SST : 44 N*m (449 kgf*cm, 32 ft.*lbf)
with SST : 40 N*m (408 kgf*cm, 30 ft.*lbf)

Text in Illustration
*1 Fulcrum Length

HINT:
·

Use a torque wrench with a fulcrum length of 300 mm (11.8 in.). When using a torque wrench with a fulcrum length that is not 300 mm (11.8 in.), calculate the torque specification for the torque wrench and SST based on the "without SST" torque specification (See page General>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION).

·

Make sure SST and the wrench are connected in a straight line.




c.

Attach the clamp and connect the heated oxygen sensor connector.


Hide 89465 2.INSTALL HEATED OXYGEN SENSOR (for Bank 1 Sensor 2)

a.

Temporarily install the sensor to the front No. 2 exhaust pipe by hand.


b.
U163328E02
1.427,0.583 1.188,0.771 1.188,0.771 1.094,0.771 false 2.688,1.948 2.844,2.094 0.156,0.146 10 false *1 0.719,0.677 1.063,0.917 0.344,0.24 10 true SST

Using SST, tighten the heated oxygen sensor.

SST
09224-00010  

Torque:
without SST : 44 N*m (449 kgf*cm, 32 ft.*lbf)
with SST : 40 N*m (408 kgf*cm, 30 ft.*lbf)

Text in Illustration
*1 Fulcrum Length

HINT:
·

Use a torque wrench with a fulcrum length of 300 mm (11.8 in.). When using a torque wrench with a fulcrum length that is not 300 mm (11.8 in.), calculate the torque specification for the torque wrench and SST based on the "without SST" torque specification (See page General>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION).

·

Make sure SST and the wrench are connected in a straight line.




c.

Connect the heated oxygen sensor connector.