While the engine is being cranked, current flows from terminal ST2 of the ignition switch to the park/neutral position switch and also flows to terminal STA of the ECM (STA Signal).
Refer to DTC P0617 (See page Engine / Hybrid System>1VD-FTV (ENGINE CONTROL)>ECD SYSTEM (w/o DPF)>P0617).
Inspect the fuses of circuits related to this system before performing the following inspection procedure.
After replacing the ECM, the new ECM needs registration (See page Engine / Hybrid System>1VD-FTV (ENGINE CONTROL)>ECD SYSTEM (w/o DPF)>REGISTRATION) and initialization (See page Engine / Hybrid System>1VD-FTV (ENGINE CONTROL)>ECD SYSTEM (w/o DPF)>INITIALIZATION).
This chart is based on the premise that the engine can crank normally. If the engine cannot crank normally, proceed to Problem Symptoms Table (See page Engine / Hybrid System>1VD-FTV (ENGINE CONTROL)>ECD SYSTEM (w/o DPF)>PROBLEM SYMPTOMS TABLE).
Connect the intelligent tester to the DLC3.
Turn the ignition switch to ON.
Turn the tester on.
Enter the following menus: Powertrain / Engine / Data List / Starter Signal.
Read the value.
| Ignition Switch Condition | Starter Signal |
|---|---|
| ON | OFF |
| START | ON |
OK
(See pageEngine / Hybrid System>1VD-FTV (ENGINE CONTROL)>ECD SYSTEM (w/o DPF)>PROBLEM SYMPTOMS TABLE)
NG
Remove the ST relay from the engine room relay block.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| ST relay terminal 2 - A38-48 (STA) | Always | Below 1 Ω |
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| ST relay terminal 2 - A52-48 (STA) | Always | Below 1 Ω |
Reinstall the starter relay (ST).
Reconnect the ECM connector.
OK
NG