The EGR valve position sensor is mounted on the EGR valve and used for detecting the lift amount of the valve. The lift amount detected by the sensor is provided to the ECM as feedback. The ECM then regulates the lift amount of the valve in accordance with engine running conditions.
| DTC Detection Drive Pattern | DTC Detection Condition | Trouble Area |
|---|---|---|
| Ignition switch ON for 5 seconds | No. 1 EGR valve position sensor output voltage is less than 0.1 V for 5 seconds (1 trip detection logic). | ·
Open in No. 1 EGR valve position sensor circuit ·
No. 1 EGR valve (EGR valve position sensor) ·
ECM |
| DTC Detection Drive Pattern | DTC Detection Condition | Trouble Area |
|---|---|---|
| Ignition switch ON for 5 seconds | No. 1 EGR valve position sensor output voltage is more than 4.9 V for 5 seconds (1 trip detection logic). | ·
Short in No. 1 EGR valve position sensor circuit ·
No. 1 EGR valve (EGR valve position sensor) ·
ECM |
| DTC Detection Drive Pattern | DTC Detection Condition | Trouble Area |
|---|---|---|
| Ignition switch ON for 5 seconds | No. 2 EGR valve position sensor output voltage is less than 0.1 V for 5 seconds (1 trip detection logic). | ·
Open in No. 2 EGR valve position sensor circuit ·
No. 2 EGR valve (EGR valve position sensor) ·
ECM |
| DTC Detection Drive Pattern | DTC Detection Condition | Trouble Area |
|---|---|---|
| Ignition switch ON for 5 seconds | No. 2 EGR valve position sensor output voltage is more than 4.9 V for 5 seconds (1 trip detection logic). | ·
Short in No. 2 EGR valve position sensor circuit ·
No. 2 EGR valve (EGR valve position sensor) ·
ECM |
When the output voltage of the EGR valve position sensor deviates from the normal operating range of 0.1 to 4.9 V for more than 5 seconds, the ECM interprets this as a malfunction of the sensor circuit, and illuminates the MIL.
Refer to DTC P0400 (See page Engine / Hybrid System>1VD-FTV (ENGINE CONTROL)>ECD SYSTEM (w/o DPF)>P0400).
After replacing the ECM, the new ECM needs registration (See page Engine / Hybrid System>1VD-FTV (ENGINE CONTROL)>ECD SYSTEM (w/o DPF)>REGISTRATION) and initialization (See page Engine / Hybrid System>1VD-FTV (ENGINE CONTROL)>ECD SYSTEM (w/o DPF)>INITIALIZATION).
Read freeze frame data using the intelligent tester. Freeze frame data records the engine condition when malfunctions are detected. When troubleshooting, freeze frame data can help determine if the vehicle was moving or stationary, if the engine was warmed up or not, and other data from the time the malfunction occurred.
Data List items "EGR Lift Sensor Volt %" and "EGR Lift Sensor Volt % #2" are values calculated by converting the EGR position sensor output voltage of 0 to 5 V to a percentage from 0 to 100%.
Disconnect the EGR valve connector.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| C87-3 (VC) - C87-2 (E2) | Ignition switch ON | 4.5 to 5.5 V |
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| C88-3 (VC) - C88-2 (E2) | Ignition switch ON | 4.5 to 5.5 V |
OK
NG
Disconnect the EGR valve connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3 (VC) - 2 (E2) | 20°C (68°F) | 2.45 to 4.55 kΩ |
| 4 (EGLS) - 2 (E2) | 20°C (68°F) | 2.45 to 4.55 kΩ |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3 (VC) - 2 (E2) | 20°C (68°F) | 2.45 to 4.55 kΩ |
| 4 (EGS2) - 2 (E2) | 20°C (68°F) | 2.45 to 4.55 kΩ |
OK
NG
Disconnect the EGR valve connector.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| C87-3 (VC) - C45-90 (VCEG) | Always | Below 1 Ω |
| C87-4 (EGLS) - C45-89 (EGLS) | Always | Below 1 Ω |
| C87-2 (E2) - C45-87 (EEGL) | Always | Below 1 Ω |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| C88-3 (VC) - C45-90 (VCEG) | Always | Below 1 Ω |
| C88-4 (EGS2) - C45-88 (EGS2) | Always | Below 1 Ω |
| C88-2 (E2) - C45-87 (EEGL) | Always | Below 1 Ω |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| C87-3 (VC) - C46-90 (VCEG) | Always | Below 1 Ω |
| C87-4 (EGLS) - C46-89 (EGLS) | Always | Below 1 Ω |
| C87-2 (E2) - C46-87 (EEGL) | Always | Below 1 Ω |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| C88-3 (VC) - C46-90 (VCEG) | Always | Below 1 Ω |
| C88-4 (EGS2) - C46-88 (EGS2) | Always | Below 1 Ω |
| C88-2 (E2) - C46-87 (EEGL) | Always | Below 1 Ω |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| C87-3 (VC) or C45-90 (VCEG) - Body ground | Always | 10 kΩ or higher |
| C87-4 (EGLS) or C45-89 (EGLS) - Body ground | Always | 10 kΩ or higher |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| C88-3 (VC) or C45-90 (VCEG) - Body ground | Always | 10 kΩ or higher |
| C88-4 (EGS2) or C45-88 (EGS2) - Body ground | Always | 10 kΩ or higher |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| C87-3 (VC) or C46-90 (VCEG) - Body ground | Always | 10 kΩ or higher |
| C87-4 (EGLS) or C46-89 (EGLS) - Body ground | Always | 10 kΩ or higher |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| C88-3 (VC) or C46-90 (VCEG) - Body ground | Always | 10 kΩ or higher |
| C88-4 (EGS2) or C46-88 (EGS2) - Body ground | Always | 10 kΩ or higher |
OK
NG
Replace the ECM (See page Engine / Hybrid System>1VD-FTV (ENGINE CONTROL)>ECM>REMOVAL).
NEXT
Replace the EGR valve assembly (No. 1 or No. 2) (See page Engine / Hybrid System>1VD-FTV (EMISSION CONTROL)>EGR VALVE>REMOVAL).
NEXT
NEXT
Connect the intelligent tester to the DLC3.
Clear the DTCs (See page Engine / Hybrid System>1VD-FTV (ENGINE CONTROL)>ECD SYSTEM (w/o DPF)>DTC CHECK / CLEAR).
Turn the ignition switch off.
Turn the ignition switch to ON for 5 seconds.
Enter the following menus: Powertrain / Engine / DTC.
Confirm that the DTC is not output again.
NEXT