The glow plug is mounted inside the engine combustion chamber. To ensure efficient engine starting with a cold engine, the ECM calculates a time interval of the current that needs to flow through the glow plug depending on the starting engine coolant temperature when the engine switch is turned on (IG). The ECM then turns on the glow relay and permits current to flow through the glow plug based on the ECM calculated time. The glow plug is then heated, and enhances fuel combustion with a cold engine.
A DTC will be stored if the glow plug or the circuit is open.
These troubleshooting procedures are for: 1) difficult engine starting in cold weather, and 2) difficulty driving/vehicle malfunctions in cold weather immediately after engine is started.
After the engine is started, the ECM performs "after-glow" for a certain period of time. In proportion to the actual engine coolant temperature, the time period varies. The after-glow reduces diesel engine knocking, white smoke emissions and engine noises when the engine is cold.
Inspect the fuses of circuits related to this system before performing the following inspection procedure.
After replacing the ECM, the new ECM needs registration (See page Engine / Hybrid System>1VD-FTV (ENGINE CONTROL)>ECD SYSTEM (w/ DPF)>REGISTRATION) and initialization (See page Engine / Hybrid System>1VD-FTV (ENGINE CONTROL)>ECD SYSTEM (w/ DPF)>INITIALIZATION).
Remove the GLOW 1 relay from the engine room relay block.
Remove the GLOW 2 relay from the engine room relay block.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| GLOW 1 relay (2) - Body ground | Engine switch on (IG) | 11 to 14 V |
| GLOW 2 relay (2) - Body ground | Engine switch on (IG) | 11 to 14 V |
OK
NG
Inspect the GLOW 1 relay (See page Engine / Hybrid System>1VD-FTV (STARTING)>RELAY>ON-VEHICLE INSPECTION).
Inspect the GLOW 2 relay (See page Engine / Hybrid System>1VD-FTV (STARTING)>RELAY>ON-VEHICLE INSPECTION).
OK
NG
Remove the GLOW 1 and GLOW 2 fuses from the engine room relay block.
Measure the resistance according to the value(s) in the table below.
| Component | Condition | Specified Condition |
|---|---|---|
| GLOW 1 H-fuse | Always | Below 1 Ω |
| GLOW 2 H-fuse | Always | Below 1 Ω |
OK
NG
Inspect the glow plug assembly (See page Engine / Hybrid System>1VD-FTV (STARTING)>GLOW PLUG>ON-VEHICLE INSPECTION).
OK
NG
Check the glow plug installation (See page Engine / Hybrid System>1VD-FTV (STARTING)>GLOW PLUG>INSTALLATION).
Glow plugs are installed securely.
OK
NG
Remove the GLOW 1 relay from the engine room relay block.
Disconnect the C77 glow plug connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| GLOW 1 relay (3) - C77-1 | Always | Below 1 Ω |
| GLOW 1 relay (5) - Positive (+) battery terminal cable | Always | Below 1 Ω |
| GLOW 1 relay (1) - Body ground | Always | Below 1 Ω |
Remove the GLOW 2 relay from the engine room relay block.
Disconnect the C78 glow plug connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| GLOW 2 relay (3) - C78-1 | Always | Below 1 Ω |
| GLOW 2 relay (5) - Positive (+) battery terminal cable | Always | Below 1 Ω |
| GLOW 2 relay (1) - Body ground | Always | Below 1 Ω |
OK
(See pageEngine / Hybrid System>1VD-FTV (ENGINE CONTROL)>ECD SYSTEM (w/ DPF)>CHECK FOR INTERMITTENT PROBLEMS)
NG
Remove the GLOW 1 relay from the engine room relay block.
Remove the GLOW 2 relay from the engine room relay block.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| GLOW 1 relay (2) - A38-12 (GREL) | Always | Below 1 Ω |
| GLOW 2 relay (2) - A38-23 (GRL2) | Always | Below 1 Ω |
| GLOW 1 relay (2) or A38-12 (GREL) - Body ground | Always | 10 kΩ or higher |
| GLOW 2 relay (2) or A38-23 (GRL2) - Body ground | Always | 10 kΩ or higher |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| GLOW 1 relay (2) - A52-12 (GREL) | Always | Below 1 Ω |
| GLOW 2 relay (2) - A52-23 (GRL2) | Always | Below 1 Ω |
| GLOW 1 relay (2) or A52-12 (GREL) - Body ground | Always | 10 kΩ or higher |
| GLOW 2 relay (2) or A52-23 (GRL2) - Body ground | Always | 10 kΩ or higher |
OK