Home › Engine / Hybrid System › 1VD-FTV (ENGINE CONTROL) › ECD SYSTEM (w/ DPF) › from 2015.08
RM2660E _51 Engine / Hybrid System _052773 1VD-FTV ENGINE CONTROL _0254999 ECD SYSTEM(w/ DPF) J

1VD-FTV ENGINE CONTROL  ECD SYSTEM(w/ DPF)  Injector Circuit  


DESCRIPTION

The injector driver drives the injectors at high speeds with a high-voltage DC/DC converter. The ECM constantly monitors the injector driver and stops the engine if an abnormal condition is detected.

PROCEDURE

1.CHECK HARNESS AND CONNECTOR (POWER SOURCE)
a.
U163303E01
0.663,1.879 0.998,2.030 0.334,0.151 10 GND 0.16,0.111 0.374,0.292 0.214,0.181 10 *a 0.688,0.602 0.844,0.758 0.156,0.156 10 *b 0.284,0.776 0.678,0.932 0.394,0.156 10 C150 0.739,1.098 0.895,1.253 0.156,0.156 10 *c 1.404,1.124 0.871,1.879 false 0.287,1.208 0.681,1.364 0.394,0.156 10 C154 1.591,1.458 2.166,1.894 false 2.096,1.931 2.430,2.082 0.334,0.151 10 +B

Disconnect the EDU connector.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
No. 1
Tester Connection Condition Specified Condition
C150-3 (+B) - C150-1 (GND) Ignition switch ON 11 to 14 V


Standard Resistance:
No. 2
Tester Connection Condition Specified Condition
C154-3 (+B) - C154-1 (GND) Ignition switch ON 11 to 14 V



*a Front view of wire harness connector
(to Injector Driver)
*b for No. 1
*c for No. 2

c.

Reconnect the injector driver connectors.



OK

NG

2.INSPECT EDU RELAY
2.INSPECT EDU RELAY

OK

3.CHECK HARNESS AND CONNECTOR (INJECTOR DRIVER - INTEGRATION RELAY)

NG

REPLACE EDU RELAY

3.CHECK HARNESS AND CONNECTOR (INJECTOR DRIVER - INTEGRATION RELAY)
a.

Remove the integration relay from the engine room relay block.


b.

Remove the EDU relay (EDU NO. 1 or EDU NO. 2).


c.

Disconnect the ECM connector.


d.

Disconnect the injector driver connector.


e.

Measure the resistance according to the value(s) in the table below.

Standard Resistance (No. 1):
for LHD
Tester Connection Condition Specified Condition
1S-11 - EDU NO. 1 relay (1) Always Below 1 Ω
C150-3 (+B) - EDU NO. 1 relay (5) Always Below 1 Ω
1S-11 or EDU NO. 1 relay (1) - Body ground Always 10 kΩ or higher
C150-3 (+B) or EDU NO. 1 relay (5) - Body ground Always 10 kΩ or higher

for RHD
Tester Connection Condition Specified Condition
1S-11 - EDU NO. 1 relay (1) Always Below 1 Ω
C150-3 (+B) - EDU NO. 1 relay (5) Always Below 1 Ω
1S-11 or EDU NO. 1 relay (1) - Body ground Always 10 kΩ or higher
C150-3 (+B) or EDU NO. 1 relay (5) - Body ground Always 10 kΩ or higher


Standard Resistance (No. 2):
for LHD
Tester Connection Condition Specified Condition
1P-12 - EDU NO. 2 relay (1) Always Below 1 Ω
C154-3 (+B) - EDU NO. 2 relay (5) Always Below 1 Ω
1P-12 - EDU NO. 2 relay (1) - Body ground Always 10 kΩ or higher
C154-3 (+B) or EDU NO. 2 relay (5) - Body ground Always 10 kΩ or higher

for RHD
Tester Connection Condition Specified Condition
1P-12 - EDU NO. 2 relay (1) Always Below 1 Ω
C154-3 (+B) - EDU NO. 2 relay (5) Always Below 1 Ω
1P-12 - EDU NO. 2 relay (1) - Body ground Always 10 kΩ or higher
C154-3 (+B) or EDU NO. 2 relay (5) - Body ground Always 10 kΩ or higher




OK

4.CHECK HARNESS AND CONNECTOR (ECM - INTEGRATION RELAY)

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

4.CHECK HARNESS AND CONNECTOR (ECM - INTEGRATION RELAY)
a.

Remove the integration relay from the engine room relay block and junction block assembly.


b.

Disconnect the ECM connector.


c.

Measure the resistance according to the value(s) in the table below.

Standard Resistance (No. 1):
for LHD
Tester Connection Condition Specified Condition
A38-45 (IREL) - EDU NO. 1 relay (2) Always Below 1 Ω
A38-45 (IREL) or EDU NO. 1 relay (2) - Body ground Always 10 kΩ or higher

for RHD
Tester Connection Condition Specified Condition
A52-45 (IREL) - EDU NO. 1 relay (2) Always Below 1 Ω
A52-45 (IREL) or EDU NO. 1 relay (2) - Body ground Always 10 kΩ or higher


Standard Resistance (No. 2):
for LHD
Tester Connection Condition Specified Condition
A38-46 (IRL2) - EDU NO. 2 relay (2) Always Below 1 Ω
A38-46 (IRL2) or EDU NO. 2 relay (2) - Body ground Always 10 kΩ or higher

for RHD
Tester Connection Condition Specified Condition
A52-46 (IRL2) - EDU NO. 2 relay (2) Always Below 1 Ω
A52-46 (IRL2) or EDU NO. 2 relay (2) - Body ground Always 10 kΩ or higher



d.

Reconnect the ECM connector.


e.

Reinstall the integration relay.



OK

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR