17410
1.INSTALL FRONT EXHAUST PIPE ASSEMBLY
Install a new gasket and the front exhaust pipe to the exhaust manifold RH with 2 new nuts.
Connect the heated oxygen sensor connector.
89465A
2.INSTALL HEATED OXYGEN SENSOR (for Bank 2 Sensor 2)
17450B
3.INSTALL FRONT NO. 2 EXHAUST PIPE ASSEMBLY
Install a new gasket and the front No. 2 exhaust pipe to the exhaust manifold LH with 2 new nuts.
Connect the heated oxygen sensor connector.
Hook the wire harness to the bracket.
17420
4.INSTALL CENTER EXHAUST PIPE ASSEMBLY
Check the free length.
Using a vernier caliper, measure the free length of the compression spring.
43 mm (1.693 in.)
If the free length is less than the minimum, replace the compression spring.
Connect the center exhaust pipe to the 3 exhaust pipe supports.
Install 2 new gaskets to the front exhaust pipe and front No. 2 exhaust pipe.
Install the center exhaust pipe with the 4 bolts and 2 compression springs.
17430
5.INSTALL TAILPIPE ASSEMBLY
Install the tailpipe to the 2 exhaust pipe supports.
Set a new gasket to the center exhaust pipe.
Connect the tailpipe to the center pipe with a new clamp.
Install the clamp within the angle range shown in the illustration.
89465
6.INSTALL HEATED OXYGEN SENSOR (for Bank 1 Sensor 2)
7.INSPECT FOR EXHAUST GAS LEAK