Use the same procedures for the RH side and LH side.
The procedures listed below are for the LH side.
A bolt without a torque specification is shown in the standard bolt chart (See page General>SPECIFICATIONS>STANDARD BOLT>SPECIFIED TORQUE FOR STANDARD BOLTS).
491B1
1.INSTALL REAR NO. 2 SUSPENSION CONTROL ACCUMULATOR BRACKET LH
Install the bracket to the shock absorber control valve with the bolt.
48040
2.INSTALL REAR SHOCK ABSORBER CONTROL VALVE ASSEMBLY LH
Install the bracket to the control valve with the 3 bolts.
Install the control valve together with the bracket to the vehicle with the 3 bolts.
Connect the control valve connector.
Connect the wire harness clamp to the control valve bracket.
Install a new gasket to the No. 4 suspension control pressure hose, and connect the hose to the control valve with the union bolt.
Using a union nut wrench, connect the No. 4 height control tube to the control valve.
Use a torque wrench with a fulcrum length of 300 mm (11.8 in.).
The torque value for use with a union nut wrench is effective when the union nut wrench is parallel to the torque wrench.
49158D
3.INSTALL REAR NO. 3 SUSPENSION CONTROL ACCUMULATOR LH
Apply a small amount of suspension fluid to a new O-ring and new back-up ring and install them to the accumulator.
Install the No. 3 control accumulator to the control valve.
49050
4.INSTALL REAR SUSPENSION CONTROL ACCUMULATOR ASSEMBLY LH
Apply a small amount of suspension fluid to a new O-ring and install it to the accumulator.
Install the control accumulator to the control valve.
5.BLEED AIR FROM SUSPENSION FLUID
6.CHECK FLUID LEVEL IN RESERVOIR
7.INSPECT FOR SUSPENSION FLUID LEAK
489B0
8.INSTALL HEIGHT CONTROL UNIT PROTECTOR ASSEMBLY LH
9.INSTALL SIDE STEP ASSEMBLY LH