This is the mute signal circuit between the multi-display controller sub-assembly and television display assembly.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| L66-2 (MUT1) - Body ground | RSE playing → Source changed | Higher than 3.5 V → Below 1 V |
| L66-6 (MUT2) - Body ground | RSE playing → Source changed | Higher than 3.5 V → Below 1 V |
| *a | Component with harness connected
(Multi-display Controller Sub-assembly) |
OK
(See pageAudio / Visual / Telematics>AUDIO / VIDEO>REAR SEAT ENTERTAINMENT SYSTEM>PROBLEM SYMPTOMS TABLE)
NG
Disconnect the L66 multi-display controller sub-assembly connector.
Disconnect the c38 television display assembly RH connector.
Disconnect the c43 television display assembly LH connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| L66-2 (MUT1) - c38-7 (MUTE) | Always | Below 1 Ω |
| L66-2 (MUT1) - Body ground | Always | 10 kΩ or higher |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| L66-6 (MUT2) - c43-7 (MUT2) | Always | Below 1 Ω |
| L66-6 (MUT2) - Body ground | Always | 10 kΩ or higher |
OK
NG
Disconnect the c38 television display assembly RH connector.
Disconnect the c43 television display assembly LH connector.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| c38-7 (MUTE) - Body ground | RSE playing → Source changed | Higher than 3.5 V → Below 1 V |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| c43-7 (MUT2) - Body ground | RSE playing → Source changed | Higher than 3.5 V → Below 1 V |
| *A | for RH |
| *B | for LH |
| *a | Front view of wire harness connector
(to Television Display Assembly) |
| Result | Proceed to |
|---|---|
| OK (for RH) | A |
| OK (for LH) | B |
| NG | C |
A
B
C