Home › Power Source / Network › 1GR-FE (BATTERY / CHARGING) › CHARGING SYSTEM › from 2015.08
RM2660E _57 Power Source / Network _052832 1GR-FE BATTERY / CHARGING _0255519 CHARGING SYSTEM J

1GR-FE BATTERY / CHARGING  CHARGING SYSTEM  Charging Failure  


PROCEDURE

1.CHECK GENERATOR PULLEY WITH CLUTCH (ON-VEHICLE INSPECTION)
a.

Start the engine and visually check if the fan of the generator rotor assembly located inside the generator assembly is operating.

OK:

The fan of the generator rotor assembly is operating.




OK

2.CHECK GENERATOR PULLEY WITH CLUTCH (UNIT INSPECTION)

NG

2.CHECK GENERATOR PULLEY WITH CLUTCH (UNIT INSPECTION)

b.

Check the installation condition of the generator pulley cap.

OK:

The generator pulley cap is not loose or missing.



c.

Check for grease leaks (for wet pulley) or particle formation due to friction (for dry pulley).

OK:

No grease leaks (for wet pulley) or large build-up of particles (for dry pulley).



d.

Check the generator pulley with clutch for misalignment (interference with the generator assembly).

OK:

The generator pulley with clutch is correctly aligned (no interference with the generator assembly).



e.
A288972

Turn the generator pulley with clutch clockwise and counterclockwise by hand and check for noise.

OK:

Noise does not occur when turned in both directions.



f.

Turn the generator pulley with clutch clockwise and counterclockwise by hand and visually check for runout.

OK:

The generator pulley with clutch does not have runout.



g.
A288971

Using a screwdriver, hold the fan of the generator rotor assembly located inside the generator assembly in place and check that the generator with clutch pulley locks when turned clockwise and turns freely when turned counterclockwise.


OK:

The generator pulley with clutch locks when turned clockwise and turns freely when turned counterclockwise.



OK

NG