When the glass breakage sensor detects that the back door glass, quarter window glass LH or quarter window glass RH is tapped or broken, the sensor will set off the alarm for 30 seconds.
Using the intelligent tester, read the Data List.
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
|---|---|---|---|
| Glass break sensor detection | Glass breakage sensor detection / ON or OFF | ON: Glass breakage sensor operates
OFF: Glass breakage sensor does not operate |
- |
ON (glass breakage sensor operates) appears on screen.
OK
NG
| *a | Front view of wire harness connector
(to Quarter Window Assembly RH (Glass Breakage Sensor)) |
Disconnect the quarter window assembly RH (glass breakage sensor) connector.
Using an oscilloscope, check the waveform.
| Tester Connection | Condition | Tool Setting | Specified Condition |
|---|---|---|---|
| L34-2 (SSR+) - body ground | Always | 2 V/DIV., 20 ms./DIV. | Pulse generation |
OK
NG
| *a | Front view of wire harness connector
(to Quarter Window Assembly LH (Glass Breakage Sensor)) |
Disconnect the quarter window assembly LH (glass breakage sensor) connector.
Using an oscilloscope, check the waveform.
| Tester Connection | Condition | Tool Setting | Specified Condition |
|---|---|---|---|
| K26-2 (SSR+) - body ground | Always | 2 V/DIV., 20 ms./DIV. | Pulse generation |
OK
NG
| *a | Front view of wire harness connector
(to Back Window Glass (Glass Breakage Sensor)) |
Disconnect the back window glass (glass breakage sensor) connector.
Using an oscilloscope, check the waveform.
| Tester Connection | Condition | Tool Setting | Specified Condition |
|---|---|---|---|
| S10-1 (SSR+) - body ground | Always | 2 V/DIV., 20 ms./DIV. | Pulse generation |
OK
NG
| *a | Front view of wire harness connector
(to Back Window Glass (Glass Breakage Sensor)) |
Disconnect the back window glass (glass breakage sensor) connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| B-1 (E) - Body ground | Always | Below 1 Ω |
OK
NG
Disconnect the K26 quarter window assembly LH (glass breakage sensor) connector.
Disconnect the S10 back window glass (glass breakage sensor) connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| K26-1 (SSR-) - S10-1 (SSR+) | Always | Below 1 Ω |
OK
NG
Disconnect the L34 quarter window assembly RH (glass breakage sensor) connector.
Disconnect the K26 quarter window assembly LH (glass breakage sensor) connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| L34-1 (SSR-) - K26-2 (SSR+) | Always | Below 1 Ω |
OK
NG
Disconnect the L34 quarter window assembly RH (glass breakage sensor) connector.
Disconnect the E30 certification ECU (smart key ECU assembly) connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| E30-23 (GBS) - L34-2 (SSR+) | Always | Below 1 Ω |
OK
NG