This circuit is the power source circuit for the combination meter. This circuit provides 2 power source types: one is a constant power source mainly used as a backup power source, and the other is a power source mainly used for signal transmission. The constant power source is mainly used as a backup power source for the meter CPU. However, it is also used for communication. If a voltage of 12 V is not applied to terminal IG+ when the ignition switch isON, indicators will not operate.
Remove the MET and ECU-B1 fuses from the engine room relay block.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| MET fuse | Always | Below 1 Ω |
| ECU-B1 fuse |
OK
NG
Disconnect the E7 meter connector.
Measure the resistance and voltage according to the value(s) in the tables below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| E7-15 (ET) - Body ground | Always | Below 1 Ω |
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| E7-17 (B) - Body ground | Always | 11 to 14 V |
| E7-18 (IG+) - Body ground | Ignition switch ON |
| Result | Proceed to |
|---|---|
| NG | A |
| OK (w/ Multi-information Display) | B |
| OK (w/o Multi-information Display) | C |
A
B
(See pageVehicle Interior>METER / GAUGE / DISPLAY>COMBINATION METER(w/ Multi-information Display)>REMOVAL)
C