1.REMOVE DISABLE AUTO TILT AWAY FUNCTION
for Power Tilt and Power Telescopic Steering Column:
Disable the Autoaway/Return function by changing the customize parameter (See page General>INTRODUCTION>REPAIR INSTRUCTION>CUSTOMIZE PARAMETERS).
Record the current customize parameter setting (whether the Autoaway/Return function is enabled or disabled) in order to restore the current setting after finishing the operation.
Performing the above operation causes the Autoaway/Return function to be disabled when the engine switch is turned off.
Turn the engine switch on (IG). Operate the tilt and telescopic switch to fully extend and lower the steering column assembly.
Turn the engine switch off .
2. PRECAUTION
After turning the ignition switch off, waiting time may be required before disconnecting the cable from the battery terminal. Therefore, make sure to read the disconnecting the cable from the battery terminal notice before proceeding with work (See page General>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION).
3.DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL
Wait at least 90 seconds after disconnecting the cable from the negative (-) battery terminal to disable the SRS system.
When disconnecting the cable, some systems need to be initialized after the cable is reconnected (See page General>INTRODUCTION>REPAIR INSTRUCTION>INITIALIZATION).
55474C
4.REMOVE NO. 1 INSTRUMENT CLUSTER FINISH PANEL GARNISH
55449C
5.REMOVE NO. 2 INSTRUMENT PANEL FINISH PANEL CUSHION
55403C
6.REMOVE LOWER INSTRUMENT PANEL PAD SUB-ASSEMBLY LH
w/ Entry and Start System:
(See page Vehicle Interior>INTERIOR PANELS / TRIM>FRONT CONSOLE BOX(w/o Cool Box)>REMOVAL)
w/o Entry and Start System:
(See page Vehicle Interior>INTERIOR PANELS / TRIM>FRONT CONSOLE BOX(w/o Console Box Lid)>REMOVAL)
55475A
7.REMOVE NO. 2 INSTRUMENT CLUSTER FINISH PANEL GARNISH
55404C
8.REMOVE INSTRUMENT CLUSTER FINISH PANEL SUB-ASSEMBLY
for Manual Tilt and Manual Telescopic Steering Column:
Operate the tilt and telescopic lever to fully extend and lower the steering column assembly.
Detach the 4 claws.
Detach the 9 claws and remove the finish panel.
83100
9.REMOVE COMBINATION METER ASSEMBLY
Remove the 4 screws.
Disconnect the connectors, and remove the combination meter by pulling it up in the direction of the arrow in the illustration.