The voltmeter indicates the voltage applied to the IG+ terminal of the combination meter.
Remove the MET fuse from the engine room relay block.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| MET fuse | Always | Below 1 Ω |
OK
NG
Operate the intelligent tester according to the display and select Active Test (See page Vehicle Interior>METER / GAUGE / DISPLAY>METER / GAUGE SYSTEM>DATA LIST / ACTIVE TEST).
| Tester Display | Test Part | Control Range | Diagnostic Note |
|---|---|---|---|
| Volt meter Operation | Voltmeter | 0, 3, 6, 9, 12, 15, or 18 | Perform the test with the vehicle stopped and engine idling. |
Needle indication is normal.
| Result | Proceed to |
|---|---|
| OK | A |
| NG (w/ Multi-information Display) | B |
| NG (w/o Multi-information Display) | C |
A
B
(See pageVehicle Interior>METER / GAUGE / DISPLAY>COMBINATION METER(w/ Multi-information Display)>REMOVAL)
C
(See pageVehicle Interior>METER / GAUGE / DISPLAY>COMBINATION METER(w/o Multi-information Display)>REMOVAL)
Disconnect the E7 meter connector.
Measure the resistance and voltage according to the value(s) in the tables below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| E7-15 (ET) - Body ground | Always | Below 1 Ω |
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| E7-18 (IG+) | Ignition switch ON | 11 to 14 V |
| Ignition switch off | Below 1 V |
| Result | Proceed to |
|---|---|
| NG | A |
| OK (w/ Multi-information Display) | B |
| OK (w/o Multi-information Display) | C |
A
B
(See pageVehicle Interior>METER / GAUGE / DISPLAY>COMBINATION METER(w/ Multi-information Display)>REMOVAL)
C
(See pageVehicle Interior>METER / GAUGE / DISPLAY>COMBINATION METER(w/o Multi-information Display)>REMOVAL)