Home › Vehicle Interior › SUPPLEMENTAL RESTRAINT SYSTEMS › AIRBAG SYSTEM › from 2015.08
RM2660E _58 Vehicle Interior _052843 SUPPLEMENTAL RESTRAINT SYSTEMS _0255601 AIRBAG SYSTEM C

SUPPLEMENTAL RESTRAINT SYSTEMS  AIRBAG SYSTEM  B1845/61  Short in Curtain Shield Squib LH 2nd Step Circuit  B1846/61  Open in Curtain Shield Squib LH 2nd Step Circuit  B1847/61  Short to GND in Curtain Shield Squib LH 2nd Step Circuit  B1848/61  Short to B+ in Curtain Shield Squib LH 2nd Step Circuit  


DESCRIPTION

The curtain shield squib LH 2nd step circuit consists of the center airbag sensor and the curtain shield airbag LH.

The circuit instructs the SRS to deploy when deployment conditions are met.

These DTCs are stored when a malfunction is detected in the curtain shield squib LH 2nd step circuit.

DTC Code DTC Detection Condition Trouble Area
B1845/61 When one of the following conditions is met:
·

The center airbag sensor receives a line short circuit signal 5 times in the curtain shield squib LH 2nd step circuit during the primary check.

·

A curtain shield squib LH malfunction.

·

A center airbag sensor malfunction.


·

Floor wire

·

Curtain shield airbag assembly LH (Curtain shield squib LH 2nd step)

·

Center airbag sensor assembly


B1846/61 When one of the following conditions is met:
·

The center airbag sensor receives an open circuit signal in the curtain shield squib LH 2nd step circuit for 2 seconds.

·

A curtain shield squib LH malfunction.

·

A center airbag sensor malfunction.


·

Floor wire

·

Curtain shield airbag assembly LH (Curtain shield squib LH 2nd step)

·

Center airbag sensor assembly


B1847/61 When one of the following conditions is met:
·

The center airbag sensor receives a short circuit to ground signal in the curtain shield squib LH 2nd step circuit for 0.5 seconds.

·

A curtain shield squib LH malfunction.

·

A center airbag sensor malfunction.


·

Floor wire

·

Curtain shield airbag assembly LH (Curtain shield squib LH 2nd step)

·

Center airbag sensor assembly


B1848/61 When one of the following conditions is met:
·

The center airbag sensor receives a short circuit to B+ signal in the curtain shield squib LH 2nd step circuit for 0.5 seconds.

·

A curtain shield squib LH malfunction.

·

A center airbag sensor malfunction.


·

Floor wire

·

Curtain shield airbag assembly LH (Curtain shield squib LH 2nd step)

·

Center airbag sensor assembly



WIRING DIAGRAM

C174615E05
4.847,2.502 5.284,2.667 0.437,0.165 10 CL2- 4.847,1.648 5.236,1.813 0.389,0.165 10 CL2+ 1.928,2.601 2.355,2.766 0.427,0.165 10 CL2- 1.928,1.529 2.355,1.694 0.427,0.165 10 CL2+ 2.472,2.374 2.675,2.555 0.203,0.181 10 2 2.472,1.52 2.675,1.701 0.203,0.181 10 1 0.637,3.292 2.841,3.468 2.204,0.177 10 Curtain Shield Squib LH 2nd Step 0.637,3.128 0.978,3.266 0.341,0.138 10 K9 4.931,4.34 6.329,4.516 1.398,0.177 10 Center Airbag Sensor 4.931,4.176 5.272,4.314 0.341,0.138 10 K27 4.5,1.555 4.722,1.721 0.222,0.166 10 12 4.5,2.369 4.722,2.535 0.222,0.166 10 11

CAUTION / NOTICE / HINT

NOTICE:
·

After turning the ignition switch off, waiting time may be required before disconnecting the cable from the battery terminal. Therefore, make sure to read the disconnecting the cable from the battery terminal notice before proceeding with work (See page General>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION).

·

When disconnecting the cable, some systems need to be initialized after the cable is reconnected (See page General>INTRODUCTION>REPAIR INSTRUCTION>INITIALIZATION).

·

After replacing the center airbag sensor assembly, refer to initialization (See page General>INTRODUCTION>REPAIR INSTRUCTION>INITIALIZATION).



HINT:

To perform the simulation method, enter the check mode (signal check) with the intelligent tester (See page Vehicle Interior>SUPPLEMENTAL RESTRAINT SYSTEMS>AIRBAG SYSTEM>CHECK MODE PROCEDURE), and then wiggle each connector of the airbag system or drive the vehicle on various type of road (See page Vehicle Interior>SUPPLEMENTAL RESTRAINT SYSTEMS>AIRBAG SYSTEM>DIAGNOSIS SYSTEM).


PROCEDURE

1.CHECK CURTAIN SHIELD AIRBAG LH (CURTAIN SHIELD SQUIB LH 2ND STEP)
a.
U156188E01
0.133,2.23 2.539,2.636 2.406,0.406 10 Front view of wire harness connector: (to Curtain Shield Squib LH 2nd Step) 0.195,1.645 2.470,1.805 2.276,0.161 10 Curtain Shield Squib LH 2nd Step 1.559,1.24 2.967,1.423 1.407,0.184 10 Center Airbag Sensor 1.387,0.658 1.567,0.837 0.179,0.179 10 C 1.172,0.658 1.311,0.852 0.139,0.194 10 D 1.059,0.522 1.057,1.577 false 0.484,3.436 0.779,3.592 0.295,0.156 10 K9 2.215,3.411 3.113,3.643 0.899,0.232 10 Connector C 2.507,3.952 2.808,4.093 0.302,0.141 10 SST 2.09,3.677 2.475,4.03 false

Turn the ignition switch off.


b.

Disconnect the cable from the negative (-) battery terminal, and wait for at least 90 seconds.


c.

Disconnect the connectors from the curtain shield squib LH 2nd step.


d.

Connect the black wire side of SST (resistance: 2.1 Ω) to connector C.

CAUTION:

Never connect the tester to the curtain shield airbag LH (curtain shield squib LH 2nd step) for measurement, as this may lead to a serious injury due to airbag deployment.


NOTICE:
·

Do not forcibly insert SST into the terminals of the connector when connecting SST.

·

Insert SST straight into the terminals of the connector.




SST
09843-18061  

e.

Connect the cable to the negative (-) battery terminal, and wait for at least 2 seconds.


f.

Turn the ignition switch to ON, and wait for at least 60 seconds.



h.

Turn the ignition switch off.


i.

Turn the ignition switch to ON, and wait for at least 60 seconds.


j.

Check for DTCs (See page Vehicle Interior>SUPPLEMENTAL RESTRAINT SYSTEMS>AIRBAG SYSTEM>DTC CHECK / CLEAR).

OK:

DTC B1845, B1846, B1847 or B1848 is not output.


HINT:

Codes other than DTC B1845, B1846, B1847 and B1848 may be output at this time, but they are not related to this check.




OK

NG

2.CHECK CONNECTOR
2.CHECK CONNECTOR
a.

Turn the ignition switch off.


b.

Disconnect the cable from the negative (-) battery terminal, and wait for at least 90 seconds.


c.

Disconnect SST from connector C.


d.

Check that the floor wire connectors (on the curtain shield squib LH 2nd step side) are not damaged.

OK:

The lock button is not disengaged, and the claw of the lock is not deformed or damaged.




OK

3.CHECK FLOOR WIRE (CURTAIN SHIELD SQUIB LH 2ND STEP CIRCUIT)

NG

REPLACE FLOOR WIRE

3.CHECK FLOOR WIRE (CURTAIN SHIELD SQUIB LH 2ND STEP CIRCUIT)
a.
U164892E01
0.112,2.469 2.518,2.875 2.406,0.406 10 Front view of wire harness connector: (to Curtain Shield Squib LH 2nd Step) 0.772,0.104 1.491,0.289 0.719,0.185 10 Floor Wire 1.684,1.524 3.092,1.707 1.407,0.184 10 Center Airbag Sensor 1.873,0.894 2.053,1.074 0.179,0.179 10 B 1.489,0.894 1.668,1.074 0.179,0.179 10 C 1.274,0.894 1.412,1.088 0.139,0.194 10 D 1.621,0.199 1.739,0.199 1.739,0.199 1.741,0.639 false 0.683,3.472 0.885,3.628 0.202,0.156 10 K9 2.193,3.487 3.092,3.719 0.899,0.232 10 Connector C 2.237,4.121 2.632,4.262 0.394,0.141 10 CL2- 1.729,3.648 2.206,4.198 false 0.161,1.893 2.353,2.107 2.192,0.214 10 Curtain Shield Squib LH 2nd Step 1.166,0.781 1.166,1.887 false 1.583,3.649 1.107,4.199 false 0.63,4.121 1.025,4.262 0.396,0.141 10 CL2+ 2.277,0.621 2.456,0.800 0.179,0.179 10 A

Disconnect the connectors from the center airbag sensor.


b.

Connect the cable to the negative (-) battery terminal, and wait for at least 2 seconds.


c.

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Switch Condition Specified Condition
K9-1 (CL2+) - Body ground Ignition switch ON Below 1 V
K9-2 (CL2-) - Body ground Ignition switch ON Below 1 V



d.

Turn the ignition switch off.


e.

Disconnect the cable from the negative (-) battery terminal, and wait for at least 90 seconds.


f.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
K9-1 (CL2+) - K9-2 (CL2-) Always Below 1 Ω



g.

Release the activation prevention mechanism built into connector B (See page Vehicle Interior>SUPPLEMENTAL RESTRAINT SYSTEMS>AIRBAG SYSTEM>DIAGNOSIS SYSTEM).


h.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
K9-1 (CL2+) - K9-2 (CL2-) Always 1 MΩ or higher
K9-1 (CL2+) - Body ground Always 1 MΩ or higher
K9-2 (CL2-) - Body ground Always 1 MΩ or higher




OK

4.CHECK CENTER AIRBAG SENSOR

NG

REPLACE FLOOR WIRE

4.CHECK CENTER AIRBAG SENSOR
a.
C146259E23
0.108,1.689 2.233,1.852 2.125,0.163 10 Curtain Shield Squib LH 2nd Step 0.842,0.531 0.842,1.646 false 1.615,1.279 3.014,1.456 1.399,0.177 10 Center Airbag Sensor 1,0.626 1.129,0.789 0.130,0.163 10 D 1.134,0.629 1.269,0.792 0.135,0.163 10 C

Connect the connectors to the curtain shield squib LH 2nd step and the center airbag sensor.


b.

Connect the cable to the negative (-) battery terminal, and wait for at least 2 seconds.


c.

Turn the ignition switch to ON, and wait for at least 60 seconds.



e.

Turn the ignition switch off.


f.

Turn the ignition switch to ON, and wait for at least 60 seconds.


g.

Check for DTCs (See page Vehicle Interior>SUPPLEMENTAL RESTRAINT SYSTEMS>AIRBAG SYSTEM>DTC CHECK / CLEAR).

OK:

DTC B1845, B1846, B1847 or B1848 is not output.


HINT:

Codes other than DTC B1845, B1846, B1847 and B1848 may be output at this time, but they are not related to this check.




OK

NG