Home › Vehicle Interior › HEATING / AIR CONDITIONING › AIR CONDITIONING SYSTEM (for Automatic Air Conditioning System) › from 2015.08
RM2660E _58 Vehicle Interior _052847 HEATING / AIR CONDITIONING _0255699 AIR CONDITIONING SYSTEM(for Automatic Air Conditioning System) C

HEATING / AIR CONDITIONING  AIR CONDITIONING SYSTEM(for Automatic Air Conditioning System)  B1417/17  Rear Evaporator Temperature Sensor Circuit  


DESCRIPTION

The No. 2 cooler thermistor (room temperature sensor) is installed on the evaporator in the rear air conditioning unit to detect the cooled air temperature that has passed through the evaporator and control the air conditioning. It sends appropriate signals to the air conditioning amplifier assembly. The resistance of the No. 2 cooler thermistor (room temperature sensor) changes in accordance with the cooled air temperature that has passed through the rear evaporator. As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases.

The air conditioning amplifier assembly applies voltage (5 V) to the No. 2 cooler thermistor (room temperature sensor) and reads voltage changes as the resistance of the No. 2 cooler thermistor (room temperature sensor) changes. This sensor is used for frost prevention.

DTC Code DTC Detection Condition Trouble Area
B1417/17 An open or short in the No. 2 cooler thermistor (room temperature sensor) circuit.
·

Harness or connector

·

No. 2 air conditioning harness assembly (No. 2 cooler thermistor [room temperature sensor])

·

Air conditioning amplifier assembly



WIRING DIAGRAM

E312530E68
4.469,1.625 4.927,1.823 0.458,0.198 10 false E35 4.469,1.823 6.75,2.073 2.281,0.25 10 false Air Conditioning Amplifier Assembly 4.813,0.542 5.271,0.74 0.458,0.198 10 false TEC 4.823,1.01 5.281,1.208 0.458,0.198 10 false SG 4.521,1.01 4.938,1.177 0.417,0.167 10 false 33 4.521,0.531 4.938,0.698 0.417,0.167 10 false 11 2.99,0.531 3.406,0.698 0.417,0.167 10 false 8 2.99,1 3.406,1.167 0.417,0.167 10 false 7 0.625,1.521 1.094,1.708 0.469,0.188 10 false K19 0.625,1.708 3.24,2.104 2.615,0.396 10 false No. 2 Air Conditioning Harness Assembly (Evaporator Temperature Sensor) 6.167,0.646 6.625,0.844 0.458,0.198 10 false AD 5.708,0.219 6.167,0.417 0.458,0.198 10 false 5 V 2.771,0.531 3.188,0.698 0.417,0.167 10 false + 2.771,1 3.188,1.167 0.417,0.167 10 false -

PROCEDURE

1.READ VALUE USING GTS (AMBIENT TEMP SENS [REAR])
a.

Use the Data List to check if the No. 2 cooler thermistor (room temperature sensor) is functioning properly (See page Vehicle Interior>HEATING / AIR CONDITIONING>AIR CONDITIONING SYSTEM (for Automatic Air Conditioning System)>DATA LIST / ACTIVE TEST).

Air Conditioner
Tester Display Measurement Item/Range Normal Condition Diagnostic Note
Ambient Temp Sens (Rear) No. 2 cooler thermistor / Min.: -29.7°C (-21.46°F), Max.: 59.55°C (139.19°F) Actual rear evaporator temperature displayed No. 2 air conditioning harness assembly (evaporator temperature sensor) system malfunction:
·

Open in the circuit: -29.7°C (- 21.46°F)

·

Short in the circuit: 59.55°C (139.19°F)



OK:

The display is as specified in the normal condition.


Result
Result Proceed to
OK (When troubleshooting according to the DTC) A
OK (When troubleshooting according to Problem Symptoms Table) B
NG C



A

REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY

B

C

2.INSPECT NO. 2 AIR CONDITIONING HARNESS ASSEMBLY (EVAPORATOR TEMPERATURE SENSOR)
2.INSPECT NO. 2 AIR CONDITIONING HARNESS ASSEMBLY (EVAPORATOR TEMPERATURE SENSOR)
a.

Remove the No. 2 air conditioning harness assembly (evaporator temperature sensor) (See page Vehicle Interior>HEATING / AIR CONDITIONING>REAR AIR CONDITIONING UNIT (w/ Heater)>DISASSEMBLY).


b.

Inspect the No. 2 air conditioning harness assembly (evaporator temperature sensor) (See page Vehicle Interior>HEATING / AIR CONDITIONING>REAR EVAPORATOR TEMPERATURE SENSOR(w/ Heater)>INSPECTION).



OK

3.CHECK HARNESS AND CONNECTOR (NO. 2 AIR CONDITIONING HARNESS ASSEMBLY -AIR CONDITIONING AMPLIFIER ASSEMBLY)

NG

3.CHECK HARNESS AND CONNECTOR (NO. 2 AIR CONDITIONING HARNESS ASSEMBLY -AIR CONDITIONING AMPLIFIER ASSEMBLY)
a.

Disconnect the K19 No. 2 air conditioning harness assembly connector.


b.

Disconnect the E35 air conditioning amplifier assembly connector.


c.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
K19-8 (+) - E35-11 (TEC) Always Below 1 Ω
K19-7 (-) - E35-33 (SG) Always Below 1 Ω
K19-7 (-) - K19-8 (+) Always 10 kΩ or higher
K19-8 (+) or E35-11 (TEC)- Body ground Always 10 kΩ or higher
K19-7 (-) or E35-33 (SG) - Body ground Always 10 kΩ or higher




OK

4.CHECK NO. 2 AIR CONDITIONING HARNESS ASSEMBLY

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

4.CHECK NO. 2 AIR CONDITIONING HARNESS ASSEMBLY
a.

Replace the No. 2 air conditioning harness assembly with a new or known good one (See page Vehicle Interior>HEATING / AIR CONDITIONING>REAR AIR CONDITIONING UNIT (w/ Heater)>DISASSEMBLY).



c.

When troubleshooting according to Problem Symptoms Table:

i.

Check the air conditioning control system operates normally.

OK:

Air conditioning control system operation returns to normal.





OK

END (NO. 2 AIR CONDITIONING HARNESS ASSEMBLY WAS DEFECTIVE)

NG

REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY