When the No. 2 air conditioning control assembly (rear blower switch) is set to position LO or higher, the contact of the CLR RR relay is closed, current flows to the rear blower motor, and the rear blower motor operates. The rear blower motor speed can be changed by exchanging the ground and the rear blower resistor circuit with the No. 2 air conditioning control assembly (rear blower switch).
Inspect the fuses for circuits related to this system before performing the following inspection procedure.
Remove the CLR RR relay from the No.1 engine room relay block.
Measure the CLR RR relay (See page Vehicle Interior>HEATING / AIR CONDITIONING>RELAY(for Rear Air Conditioning System)>ON-VEHICLE INSPECTION).
OK
NG
Remove the rear blower with fan motor sub-assembly (See page Vehicle Interior>HEATING / AIR CONDITIONING>REAR BLOWER MOTOR>REMOVAL).
Measure the rear blower with fan motor sub-assembly (See page Vehicle Interior>HEATING / AIR CONDITIONING>REAR BLOWER MOTOR>INSPECTION).
OK
NG
Remove the No. 2 air conditioning control assembly (See page Vehicle Interior>HEATING / AIR CONDITIONING>REAR AIR CONDITIONING PANEL>DISASSEMBLY).
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| ALL - E89-6 (E) | OFF | 10 kΩ or higher |
| E89-5 (LO) - E89-6 (E) | LO | Below 1 Ω |
| E89-3 (M1) - E89-6 (E) | M1 | Below 1 Ω |
| E89-4 (M2) - E89-6 (E) | M2 | Below 1 Ω |
| E89-8 (HI) - E89-6 (E) | HI | Below 1 Ω |
OK
NG
Remove the rear blower resistor (See page Vehicle Interior>HEATING / AIR CONDITIONING>BLOWER RESISTOR(w/o Heater)>REMOVAL).
Inspect the rear blower resistor (See page Vehicle Interior>HEATING / AIR CONDITIONING>BLOWER RESISTOR(w/o Heater)>INSPECTION).
OK
NG
Replace the rear cooling unit expansion valve (See page Vehicle Interior>HEATING / AIR CONDITIONING>REAR AIR CONDITIONING UNIT (w/o Heater)>DISASSEMBLY).
Since the rear cooling unit expansion valve cannot be inspected while it is removed from the vehicle, replace the rear cooling unit expansion valve with a normal one and check that the condition returns to normal.
Same problem does not occur.
OK
(See pageVehicle Interior>HEATING / AIR CONDITIONING>REAR AIR CONDITIONING UNIT (w/o Heater)>DISASSEMBLY)
NG
Disconnect the wiring air conditioning harness sub-assembly connector.
Disconnect the z52 rear blower resistor connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 6 (M1) - z52-2 (M1) | Always | Below 1 Ω |
| 5 (M2) - z52-3 (M2) | Always | Below 1 Ω |
| 4 (HI) - z52-1 (HI) | Always | Below 1 Ω |
| 7 (LO) - z52-4 (LO) | Always | Below 1 Ω |
| 6 (M1) or z52-2 (M1) - Body ground | Always | 10 kΩ or higher |
| 5 (M2) or z52-3 (M2) - Body ground | Always | 10 kΩ or higher |
| 4 (HI) or z52-1 (HI) - Body ground | Always | 10 kΩ or higher |
| 7 (LO) or z52-4 (LO) - Body ground | Always | 10 kΩ or higher |
OK
NG
Disconnect the E89 No. 2 air conditioning control assembly connector.
Disconnect the Wiring air conditioning harness sub-assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| E89-3 (M1) - 6 (M1) | Always | Below 1 Ω |
| E89-4 (M2) - 5 (M2) | Always | Below 1 Ω |
| E89-8 (HI) - 4 (HI) | Always | Below 1 Ω |
| E89-5 (LO) - 7 (LO) | Always | Below 1 Ω |
| E89-6 (E) - Body ground | Always | Below 1 Ω |
| E89-3 (M1) or 6 (M1) - Body ground | Always | 10 kΩ or higher |
| E89-4 (M2) or 5 (M2) - Body ground | Always | 10 kΩ or higher |
| E89-8 (HI) or 4 (HI) - Body ground | Always | 10 kΩ or higher |
| E89-5 (LO) or 7 (LO) - Body ground | Always | 10 kΩ or higher |
OK
NG
Disconnect the z52 rear blower resistor connector.
Disconnect the z49 rear blower with fan motor sub-assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| z52-1 (HI) - z49-1 | Always | Below 1 Ω |
| z52-1 (HI) or z49-1 - Body ground | Always | 10 kΩ or higher |
OK
NG
Disconnect the rear blower with fan motor sub-assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| z49-2 - Body ground | Always | Below 1 Ω |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| z49-2 - Body ground | Ignition switch ON
Heater control (blower switch) HI |
11 to 14 V |
| *a | Front view of wire harness connector
(to Rear Blower with Fan Motor Sub-assembly) |
OK
NG
Disconnect the air conditioning amplifier connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| E81-14 (GND) - Body ground | Always | Below 1 Ω |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| E81-18 (RCRL) - Body ground | ·
Ignition switch ON ·
Heater control (blower switch): OFF |
11 to 14 V |
| E81-18 (RCRL) - Body ground | ·
Ignition switch ON ·
Heater control (blower switch): ON |
Below 1 V |
| *a | Rear view of wire harness connector
(to Air Conditioning Amplifier Assembly) |
OK
NG