The air duct temperature sensor RH*1 or LH*2 (for front passenger side) detects the duct temperature and sends the appropriate signals to the air conditioning amplifier assembly.
| DTC Code | DTC Detection Condition | Trouble Area |
|---|---|---|
| B1429/29 | An open or short in the air duct temperature sensor RH*1 or LH*2 circuit. | ·
Air duct temperature sensor RH*1 ·
Air duct temperature sensor LH*2 ·
Harness or connector (air duct temperature sensor RH)*1 ·
Harness or connector (air duct temperature sensor LH)*2 ·
Air conditioning amplifier assembly |
*1: for LHD
*2: for RHD
Use the Data List to check if the air duct temperature sensor RH*1 or LH*2 (for front passenger side) is functioning properly.
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
|---|---|---|---|
| Foot Duct Sensor (Rear P) | Min.: -12.7°C (9.14°F)
Max.: 76.55°C (169.79°F) |
Actual air duct temperature sensor (for passenger side) displayed | Open in the circuit: -12.7°C (9.14°F)
Short in the circuit: 76.55°C (169.79°F) |
*1: for LHD
*2: for RHD
The display is as specified in the normal condition.
OK
NG
for LHD
Remove the air duct temperature sensor RH (See page Vehicle Interior>HEATING / AIR CONDITIONING>DUCT TEMPERATURE SENSOR (w/ Heater)>REMOVAL).
for RHD
Remove the air duct temperature sensor LH (See page Vehicle Interior>HEATING / AIR CONDITIONING>DUCT TEMPERATURE SENSOR (w/ Heater)>REMOVAL).
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1 (+) - 2 (-) | at 10°C (50°F) | 9.4 to 10.5 kΩ |
| at 15°C (59°F) | 7.5 to 8.3 kΩ | |
| at 20°C (68°F) | 6.0 to 6.5 kΩ | |
| at 25°C (77°F) | 4.5 to 5.2 kΩ | |
| at 30°C (86°F) | 3.8 to 4.2 kΩ | |
| at 35°C (95°F) | 3.1 to 3.4 kΩ | |
| at 40°C (104°F) | 2.5 to 2.8 kΩ | |
| at 45°C (113°F) | 2.0 to 2.3 kΩ | |
| at 50°C (122°F) | 1.6 to 2.0 kΩ | |
| at 55°C (131°F) | 1.3 to 1.6 kΩ | |
| at 60°C (140°F) | 1.1 to 1.4 kΩ |
Touching the sensor even slightly may change the resistance value. Hold the connector of the sensor.
When measuring the resistance, the sensor temperature must be the same as the ambient temperature.
As the temperature increases, the resistance decreases (see the graph).
If the resistance value is not as specified, replace the sensor.
| Result | Proceed to |
|---|---|
| OK | A |
| NG (for LHD) | B |
| NG (for RHD) | C |
A
B
C
for LHD
Disconnect the L12 sensor connector.
Disconnect the E35 amplifier connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| E35-26 (TR4) - L12-1 (+) | Always | Below 1 Ω |
| E35-12 (SG-9) - L12-2 (-) | ||
| E35-26 (TR4) - Body ground | Always | 10 kΩ or higher |
| E35-12 (SG-9) - Body ground |
for RHD
Disconnect the K21 sensor connector.
Disconnect the E35 amplifier connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| E35-25 (TR3) - K21-1 (+) | Always | Below 1 Ω |
| E35-34 (SGND) - K21-2 (-) | ||
| E35-25 (TR3) - Body ground | Always | 10 kΩ or higher |
| E35-34 (SGND) - Body ground |
OK
NG