The blower with fan motor sub-assembly is operated by signals from the air conditioning amplifier assembly. The blower with fan motor sub-assembly speed signals are transmitted by changes in the duty ratio.
The air conditioning amplifier assembly controls the blower with fan motor sub-assembly speed.
Inspect the fuses for circuits related to this system before performing the following inspection procedure.
Select the Active Test, use the GTS to generate a control command, and then check that the blower with fan motor sub-assembly operates (See page Vehicle Interior>HEATING / AIR CONDITIONING>AIR CONDITIONING SYSTEM(for Manual Air Conditioning System)>DATA LIST / ACTIVE TEST).
| Tester Display | Test Part | Control Range | Diagnostic Note |
|---|---|---|---|
| Blower Motor | Blower with fan motor sub-assembly | Min.: 0, Max.: 31 | - |
Blower with fan motor sub-assembly is operated normally using GTS.
OK
NG
Disconnect the blower with fan motor sub-assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A29-1 (GND) - Body ground | Always | Below 1 Ω |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A29-3 (+B) - Body ground | Always | 11 to 14 V |
| *a | Front view of wire harness connector
(to Blower with Fan Motor Sub-assembly) |
OK
NG
Disconnect the A29 blower with fan motor sub-assembly connector.
Disconnect the E81 air conditioning amplifier assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| A29-2 (SI) - E81-22 (BLW) | Always | Below 1 Ω |
| A29-2 (SI) or E81-22 (BLW) - Body ground | Always | 10 kΩ or higher |
OK
NG
Using an oscilloscope, check the waveform
| Item | Content |
|---|---|
| Terminal No. (Symbol) | A29-2 (SI) - Body ground |
| Tool Setting | 1 V/DIV., 500 μs/DIV. |
| Condition | ·
Ignition switch ON ·
Blower switch LO |
Waveform is as shown in the illustration.
| *a | Component with harness connected
(Blower with Fan Motor Sub-assembly) |
Waveform varies with the blower level.
OK
NG
Replace the blower with fan motor sub-assembly with a new or known good one (See page Vehicle Interior>HEATING / AIR CONDITIONING>AIR CONDITIONING AMPLIFIER>REMOVAL).
Check that the air conditioning system is operated normally.
Air conditioning system is operated normally.
OK
NG