Home › Vehicle Interior › HEATING / AIR CONDITIONING › AIR CONDITIONING SYSTEM(for Manual Air Conditioning System) › 2014.08–2015.08
RM2660E _58 Vehicle Interior _052847 HEATING / AIR CONDITIONING _0255703 AIR CONDITIONING SYSTEM(for Manual Air Conditioning System) C

HEATING / AIR CONDITIONING  AIR CONDITIONING SYSTEM(for Manual Air Conditioning System)  B1423  Pressure Sensor Circuit  


DESCRIPTION

This DTC is stored when refrigerant pressure is extremely low (0.176 MPa [1.8 kgf/cm2, 25.5 psi] or less) or extremely high (3.025 MPa [30.9 kgf/cm2, 438.6 psi] or higher). The air conditioner pressure sensor, which is installed on the pipe of the high pressure side to detect refrigerant pressure, outputs the refrigerant pressure signal to the air conditioning amplifier assembly. The air conditioning amplifier assembly converts the signal to a pressure value according to the sensor characteristics to control the compressor.

HINT:

Be sure to check the refrigerant volume first when this DTC is output because this DTC may also be stored if there is no refrigerant in the cycle.


DTC Code DTC Detection Condition Trouble Area
B1423 Either condition is met:
·

An open or short in the air conditioner pressure sensor circuit.

·

Refrigerant pressure on the high pressure side is extremely low or extremely high.


·

Air conditioner pressure sensor

·

Harness or connector

·

Cooler expansion valve

·

Cooler condenser assembly

·

Cooler dryer

·

Refrigerant pipe line

·

Air conditioning amplifier assembly



WIRING DIAGRAM

E156766E33
2.475,0.456 2.580,0.624 0.105,0.168 10 3 2.475,0.85 2.580,1.019 0.105,0.168 10 1 2.475,1.244 2.580,1.412 0.105,0.168 10 2 4.526,0.431 4.847,0.589 0.321,0.158 10 30 4.524,0.854 4.827,1.015 0.303,0.161 10 13 4.588,1.258 4.906,1.426 0.317,0.168 10 9 2.242,0.555 2.433,0.723 0.191,0.168 10 + 2.261,0.95 2.422,1.118 0.161,0.168 10 - 2.173,1.343 2.397,1.511 0.223,0.168 10 PR 0.992,1.787 1.275,1.955 0.284,0.168 10 A13 0.992,1.955 3.068,2.123 2.076,0.168 10 Air Conditioner Pressure Sensor 4.735,1.787 5.138,1.955 0.404,0.168 10 E81 4.735,1.95 7.044,2.118 2.309,0.168 10 Air Conditioning Amplifier Assembly 4.795,0.555 5.156,0.723 0.361,0.168 10 S5-1 4.795,0.95 5.156,1.118 0.361,0.168 10 SG-2 4.798,1.343 5.123,1.511 0.325,0.168 10 PRE

PROCEDURE

1.CHECK HARNESS AND CONNECTOR (PRESSURE SENSOR - BATTERY AND BODY GROUND)
a.
U166082E01
0.356,1.14 0.700,1.303 0.345,0.163 10 A13 2.408,1.785 2.545,1.948 0.137,0.163 10 + 0.971,1.721 1.108,1.884 0.137,0.163 10 - 1.977,1.488 2.36,1.806 false 1.072,1.775 1.501,1.511 false 0.103,0.087 0.294,0.243 0.191,0.156 10 *a

Disconnect the A13 air conditioner pressure sensor connector.


b.

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Switch Condition Specified Condition
A13-3 (+) - Body ground Ignition switch ON 4.75 to 5.25 V



c.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
A13-1 (-) - Body ground Always Below 1 Ω



Text in Illustration
*a Front view of wire harness connector
(to Air Conditioning Pressure Sensor)


OK

2.CHECK AIR CONDITIONER PRESSURE SENSOR

NG

4.CHECK HARNESS AND CONNECTOR (PRESSURE SENSOR - AIR CONDITIONING AMPLIFIER)
2.CHECK AIR CONDITIONER PRESSURE SENSOR
a.
U166135E01
0.158,0.108 0.373,0.277 0.215,0.169 10 *a 1.836,0.467 2.117,0.636 0.281,0.169 10 E81 0.793,0.469 1.179,0.638 0.386,0.169 10 SG-2 1.247,0.565 1.786,1.329 false 2.631,0.473 2.965,0.642 0.333,0.169 10 PRE 2.59,0.565 2.091,1.329 false

Remove the air conditioning amplifier assembly with its connectors still connected (See page Vehicle Interior>HEATING / AIR CONDITIONING>AIR CONDITIONING AMPLIFIER>REMOVAL).


b.

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Switch Condition Specified Condition
E81-9 (PRE) - E81-13 (SG-2) Engine idling
Blower switch LO level
A/C switch off
0.63 to 4.72 V


HINT:

If the measured voltage is not within the normal range, there may be a malfunction in the air conditioning amplifier assembly, air conditioner pressure sensor or wire harness. It is also possible that the amount of refrigerant may not be appropriate.



c.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Switch Condition Specified Condition
E81-13 (SG-2) - Body ground Always Below 1 Ω



Text in Illustration
*a Component with harness connected
(Air Conditioning Amplifier Assembly)


OK

3.CHECK AIR CONDITIONER PRESSURE SENSOR

NG

5.CHECK HARNESS AND CONNECTOR (PRESSURE SENSOR - AIR CONDITIONING AMPLIFIER)
3.CHECK AIR CONDITIONER PRESSURE SENSOR
a.
U166135E01
0.158,0.108 0.373,0.277 0.215,0.169 10 *a 1.836,0.467 2.117,0.636 0.281,0.169 10 E81 0.793,0.469 1.179,0.638 0.386,0.169 10 SG-2 1.247,0.565 1.786,1.329 false 2.631,0.473 2.965,0.642 0.333,0.169 10 PRE 2.59,0.565 2.091,1.329 false

Remove the air conditioning amplifier assembly with its connectors still connected (See page Vehicle Interior>HEATING / AIR CONDITIONING>AIR CONDITIONING AMPLIFIER>REMOVAL).


b.

Measure the voltage when the following conditions are met.

Measurement Condition
Item Condition
Engine Speed 2000 rpm
Vehicle Doors Fully open
Temperature Setting MAX. COOL
Blower Speed Hi
A/C Switch On
R/F Switch Recirculation
Interior Temperature 25 to 35°C (77 to 95°F)

NOTICE:
·

If refrigerant pressure on the high pressure side becomes extremely high during the inspection (the voltage exceeds 4.8 V), the fail-safe function stops compressor operation. Therefore, measure the voltage before the fail-safe operation.

·

It is necessary to measure the voltage for a certain amount of time (approximately 10 minutes) because the problem symptom may recur after a while.



HINT:

When the outside air temperature is low (below -1.5°C [29.3°F]), the compressor stops due to operation of the ambient temperature sensor and evaporator temperature sensor to prevent the evaporator from freezing. In this case, perform the inspection in a warm indoor environment.


i.

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition
E81-9 (PRE) - E81-13 (SG-2) Conditions in "Measurement Condition" chart above are met 0.63 to 4.72 V




Text in Illustration
*a Component with harness connected
(Air Conditioning Amplifier Assembly)

Result
Result Proceed to
OK (When troubleshooting according to problem symptoms table) A
OK (When troubleshooting according to the DTC) B
NG C


A

B

REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY

C

13.CHARGE REFRIGERANT
4.CHECK HARNESS AND CONNECTOR (PRESSURE SENSOR - AIR CONDITIONING AMPLIFIER)
a.

Disconnect the A13 air conditioner pressure sensor connector.


b.

Disconnect the E81 air conditioning amplifier assembly connector.


c.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
A13-1 (-) - E81-13 (SG-2) Always Below 1 Ω
A13-3 (+) - E81-30 (S5-1) Always Below 1 Ω
E81-13 (SG-2) - Body ground Always 10 kΩ or higher
E81-30 (S5-1) - Body ground Always 10 kΩ or higher




OK

REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

5.CHECK HARNESS AND CONNECTOR (PRESSURE SENSOR - AIR CONDITIONING AMPLIFIER)
a.

Disconnect the A13 air conditioner pressure sensor connector.


b.

Disconnect the E81 air conditioning amplifier assembly connector.


c.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
A13-2 (PR) - E81-9 (PRE) Always Below 1 Ω
E81-9 (PRE) - Body ground Always 10 kΩ or higher




OK

6.CHECK FOR AIR CONDITIONING SYSTEM LEAK

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

6.CHECK FOR AIR CONDITIONING SYSTEM LEAK
a.

Install a manifold gauge set.


b.

Recover the refrigerant from the air conditioning system using a refrigerant recovery unit (See page Vehicle Interior>HEATING / AIR CONDITIONING>REFRIGERANT>REPLACEMENT).


c.

Evacuate the air conditioning system and check that vacuum can be maintained in it.

OK:

Vacuum can be maintained in the air conditioning system.


HINT:

If vacuum cannot be maintained in the air conditioning system, refrigerant may be leaking from it. In this case, it is necessary to repair or replace the leaking part of the air conditioning system.




OK

7.CHARGE REFRIGERANT

NG

12.REPAIR AIR CONDITIONING SYSTEM LEAK
7.CHARGE REFRIGERANT
a.

Use a refrigerant recovery unit to recover refrigerant.


b.

Evacuate the air conditioning system.


c.

Add an appropriate amount of refrigerant (See page Vehicle Interior>HEATING / AIR CONDITIONING>REFRIGERANT>REPLACEMENT).

HINT:

If refrigerant is added and the system has not been properly evacuated (insufficient vacuum time), moisture in the air remaining in the system will freeze in the expansion valve, blocking the flow on the high pressure side. Therefore, in order to confirm the problem, recover the refrigerant and properly evacuate the system. Add an appropriate amount of refrigerant, and then check for the DTC.




NEXT

8.CHECK FOR DTC
8.CHECK FOR DTC
a.

Check for DTCs when the following conditions are met (See page Vehicle Interior>HEATING / AIR CONDITIONING>AIR CONDITIONING SYSTEM(for Manual Air Conditioning System)>DTC CHECK / CLEAR).

Measurement Condition
Item Condition
Engine Speed 2000 rpm
Vehicle Doors Fully open
Temperature Setting MAX. COOL
Blower Speed Hi
A/C Switch On
R/F Switch Recirculation
Interior Temperature 25 to 35°C (77 to 95°F)

NOTICE:

If refrigerant pressure on the high pressure side becomes high, a DTC will be stored. Therefore, it is necessary to check for DTCs after a certain amount of time (approximately 10 minutes) has passed because the DTC may be stored after the air conditioning system operates for a while.


HINT:

When the outside air temperature is low (below -1.5°C [29.3°F]), the compressor stops due to operation of the ambient temperature sensor and evaporator temperature sensor to prevent the evaporator from freezing. In this case, perform the inspection in a warm indoor environment.


Result
Result Proceed to
DTC B1423 is not output A
DTC B1423 is output B

NOTICE:

If the DTC was stored due to an insufficient or excessive amount of refrigerant, the problem may have been solved after performing the previous step. However, the root cause of insufficient refrigerant may be refrigerant leakage. Therefore, identify and repair the area where refrigerant leaks as necessary. The root cause of excessive refrigerant may be adding too much refrigerant.




A

END (AMOUNT OF REFRIGERANT IS FAULTY)

B

9.CHECK AIR CONDITIONER PRESSURE SENSOR
9.CHECK AIR CONDITIONER PRESSURE SENSOR
a.
U166136E02
2.469,1.833 2.083,1.323 false 1.396,1.833 1.771,1.323 false 0.156,0.073 0.375,0.24 0.219,0.167 10 false *a 1.823,0.479 2.104,0.646 0.281,0.167 10 false E81 1.083,1.854 1.469,2.021 0.385,0.167 10 false SG-2 2.469,1.844 2.802,2.01 0.333,0.167 10 false PRE

Remove the air conditioning amplifier assembly with its connectors still connected (See page Vehicle Interior>HEATING / AIR CONDITIONING>AIR CONDITIONING AMPLIFIER>REMOVAL).


b.

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Switch Condition Specified Condition
E81-9 (PRE) - E81-13 (SG-2) Engine idling
Blower switch LO level
A/C switch on
0.63 to 4.72 V


Text in Illustration
*a Component with harness connected
(Air Conditioning Amplifier Assembly)



OK

REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY

NG

10.REPLACE AIR CONDITIONER PRESSURE SENSOR
10.REPLACE AIR CONDITIONER PRESSURE SENSOR
a.

Temporarily replace the air conditioner pressure sensor with a new or normally functioning one (See page Vehicle Interior>HEATING / AIR CONDITIONING>AIR CONDITIONING PRESSURE SENSOR>REMOVAL).



NEXT

11.CHECK FOR DTC
11.CHECK FOR DTC
a.

Check for DTCs when the following conditions are met (See page Vehicle Interior>HEATING / AIR CONDITIONING>AIR CONDITIONING SYSTEM(for Manual Air Conditioning System)>DTC CHECK / CLEAR).

Measurement Condition
Item Condition
Engine Speed 2000 rpm
Vehicle Doors Fully open
Temperature Setting MAX. COOL
Blower Speed Hi
A/C Switch On
R/F Switch Recirculation
Interior Temperature 25 to 35°C (77 to 95°F)

NOTICE:

If refrigerant pressure on the high pressure side becomes high, a DTC will be stored. Therefore, it is necessary to check for DTCs after a certain amount of time (approximately 10 minutes) has passed because the DTC may be stored after the air conditioning system operates for a while.


HINT:
·

When the outside air temperature is low (below -1.5°C [29.3°F]), the compressor stops due to operation of the ambient temperature sensor and evaporator temperature sensor to prevent the evaporator from freezing. In this case, perform the inspection in a warm indoor environment.

·

If refrigerant pressure is not normal after replacing the expansion valve with a new or normally functioning one, the cooler condenser assembly or pipes may be clogged due to dirt, dust or other contaminants. In this case, clean or replace the cooler condenser assembly or pipes.



Result
Result Proceed to
DTC B1423 is not output A
DTC B1423 is output B



A

END (AIR CONDITIONER PRESSURE SENSOR IS FAULTY)

B

REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY

12.REPAIR AIR CONDITIONING SYSTEM LEAK
a.

Identify the area where refrigerant leaks (See page Vehicle Interior>HEATING / AIR CONDITIONING>REFRIGERANT>ON-VEHICLE INSPECTION).


b.

Repair the identified area of the air conditioning system.


c.

Evacuate the air conditioning system.



NEXT

13.CHARGE REFRIGERANT
a.

Use a refrigerant recovery unit to recover refrigerant.


b.

Evacuate the air conditioning system.


c.

Add an appropriate amount of refrigerant (See page Vehicle Interior>HEATING / AIR CONDITIONING>REFRIGERANT>REPLACEMENT).

HINT:

If refrigerant is added and the system has not been properly evacuated (insufficient vacuum time), moisture in the air remaining in the system will freeze in the expansion valve, blocking the flow on the high pressure side. Therefore, in order to confirm the problem, recover the refrigerant and properly evacuate the system. Add an appropriate amount of refrigerant, and then check for the DTC.




NEXT

14.CHECK FOR DTC
14.CHECK FOR DTC
a.

Check for DTCs when the following conditions are met (See page Vehicle Interior>HEATING / AIR CONDITIONING>AIR CONDITIONING SYSTEM(for Manual Air Conditioning System)>DTC CHECK / CLEAR).

Measurement Condition
Item Condition
Engine Speed 2000 rpm
Vehicle Doors Fully open
Temperature Setting MAX. COOL
Blower Speed Hi
A/C Switch On
R/F Switch Recirculation
Interior Temperature 25 to 35°C (77 to 95°F)

NOTICE:

If refrigerant pressure on the high pressure side becomes high, a DTC will be stored. Therefore, it is necessary to check for DTCs after a certain amount of time (approximately 10 minutes) has passed because the DTC may be stored after the air conditioning system operates for a while.


HINT:
·

When the outside air temperature is low (below -1.5°C [29.3°F]), the compressor stops due to operation of the ambient temperature sensor and evaporator temperature sensor to prevent the evaporator from freezing. In this case, perform the inspection in a warm indoor environment.

·

If refrigerant is added and the system has not been properly evacuated (insufficient vacuum time), moisture in the air remaining in the system will freeze in the expansion valve, blocking the flow on the high pressure side. Therefore, in order to confirm the problem, recover the refrigerant and properly evacuate the system. Add an appropriate amount of refrigerant and check for the DTC. If the DTC is not output after this procedure, it indicates that the cooler dryer in the cooler condenser assembly is not able to absorb moisture in the refrigerant cycle. In this case, to complete the repair, it is necessary to replace the cooler dryer.



Result
Result Proceed to
DTC B1423 is not output A
DTC B1423 is output B



A

B

15.REPLACE COOLER EXPANSION VALVE
15.REPLACE COOLER EXPANSION VALVE
a.

Temporarily replace the cooler expansion valve with a new or normally functioning one.


HINT:

Replace the cooler expansion valve with a new or normally functioning one because the cooler expansion valve is either stuck or clogged.




NEXT

16.CHARGE REFRIGERANT
16.CHARGE REFRIGERANT
a.

Use a refrigerant recovery unit to recover refrigerant.


b.

Evacuate the air conditioning system.


c.

Add an appropriate amount of refrigerant (See page Vehicle Interior>HEATING / AIR CONDITIONING>REFRIGERANT>REPLACEMENT).

HINT:

If refrigerant is added and the system has not been properly evacuated (insufficient vacuum time), moisture in the air remaining in the system will freeze in the expansion valve, blocking the flow on the high pressure side. Therefore, in order to confirm the problem, recover the refrigerant and properly evacuate the system. Add an appropriate amount of refrigerant, and then check for the DTC.




NEXT

17.CHECK FOR DTC
17.CHECK FOR DTC
a.

Check for DTCs when the following conditions are met (See page Vehicle Interior>HEATING / AIR CONDITIONING>AIR CONDITIONING SYSTEM(for Manual Air Conditioning System)>DTC CHECK / CLEAR).

Measurement Condition
Item Condition
Engine Speed 2000 rpm
Vehicle Doors Fully open
Temperature Setting MAX. COOL
Blower Speed Hi
A/C Switch On
R/F Switch Recirculation
Interior Temperature 25 to 35°C (77 to 95°F)

NOTICE:

If refrigerant pressure on the high pressure side becomes high, a DTC will be stored. Therefore, it is necessary to check for DTCs after a certain amount of time (approximately 10 minutes) has passed because the DTC may be stored after the air conditioning system operates for a while.


HINT:
·

When the outside air temperature is low (below -1.5°C [29.3°F]), the compressor stops due to operation of the ambient temperature sensor and evaporator temperature sensor to prevent the evaporator from freezing. In this case, perform the inspection in a warm indoor environment.

·

If refrigerant pressure is not normal after replacing the expansion valve with a new or normally functioning one, the cooler condenser assembly or pipes may be clogged due to dirt, dust or other contaminants. In this case, clean or replace the cooler condenser assembly or pipes.



Result
Result Proceed to
DTC B1423 is not output A
DTC B1423 is output B



A

END (COOLER EXPANSION VALVE IS FAULTY)

B

CLEAN OR REPLACE COOLER CONDENSER ASSEMBLY OR PIPES