CHECK POSITION CONTROL ECU ASSEMBLY (for LHD)
Disconnect the i17 and i19 position control ECU assembly connectors.
Measure the voltage and resistance according to the value(s) in the table below.
Measure the values on the wire harness side with the connector disconnected.
| Tester Connection | Terminal Description | Condition | Specified Condition |
|---|---|---|---|
| i17-3 (+B) - Body ground | Battery power supply | Always | 11 to 14 V |
| i19-1 (IG) - Body ground | Ignition power supply | Ignition switch off | Below 1 V |
| Ignition switch ON | 11 to 14 V | ||
| i19-15 (SYSB) - Body ground | System power source | Always | 11 to 14 V |
| i17-2 (GND) - Body ground | Ground | Always | Below 1 Ω |
| i19-27 (DBCL) - Body ground | Driver seat belt buckle switch signal | Driver seat belt unfastened | 10 kΩ or higher |
| Driver seat belt fastened | Below 1 Ω |
Reconnect the i17 and i19 position control ECU assembly connectors.
Measure the voltage and resistance according to the value (s) in the table below.
| Tester Connection | Terminal Description | Condition | Specified Condition |
|---|---|---|---|
| i17-1 (SLD+) - Body ground | Slide motor signal (forward) | Slide switch off | Below 1 V |
| Slide switch on (Forward) | 11 to 14 V | ||
| i17-5 (SLD-) - Body ground | Slide motor signal (rearward) | Slide switch off | Below 1 V |
| Slide switch on (Rearward) | 11 to 14 V | ||
| i17-6 (LFT+) - Body ground | Lifter motor signal (upward) | Lifter switch off | Below 1 V |
| Lifter switch on (Upward) | 11 to 14 V | ||
| i18-5 (LFT-) - Body ground | Lifter motor signal (downward) | Lifter switch off | Below 1 V |
| Lifter switch on (Downward) | 11 to 14 V | ||
| i17-10 (RCL+) - Body ground | Reclining motor signal (forward) | Reclining switch off | Below 1 V |
| Reclining switch on (Forward) | 11 to 14 V | ||
| i18-6 (RCL-) - Body ground | Reclining motor signal (rearward) | Reclining switch off | Below 1 V |
| Reclining switch on (Rearward) | 11 to 14 V | ||
| i17-7 (FRV+) - Body ground | Front vertical motor signal (upward) | Front vertical switch off | Below 1 V |
| Front vertical switch on (Upward) | 11 to 14 V | ||
| i18-4 (FRV-) - Body ground | Front vertical motor signal (downward) | Front vertical switch off | Below 1 V |
| Front vertical switch on (Downward) | 11 to 14 V | ||
| i17-9 (L+) - Body ground | Lumbar support adjuster motor signal (forward) | Lumbar support adjuster switch off | Below 1 V |
| Lumbar support adjuster switch on (Forward) | 11 to 14 V | ||
| i18-3 (L-) - Body ground | Lumbar support adjuster motor signal (rearward) | Lumbar support adjuster switch off | Below 1 V |
| Lumbar support adjuster switch on (Rearward) | 11 to 14 V | ||
| i19-4 (LFLF) - Body ground | Front power seat switch LH (lumbar support adjuster switch (forward)) signal | Lumbar support adjuster switch off | 11 to 14 V |
| Lumbar support adjuster switch on (Forward) | Below 1 V | ||
| i19-18 (LFLR) - Body ground | Front power seat switch LH (lumbar support adjuster switch (rearward)) signal | Lumbar support adjuster switch off | 11 to 14 V |
| Lumbar support adjuster switch on (Rearward) | Below 1 V | ||
| i19-9 (SLDF) - Body ground | Front power seat switch LH (slide switch (forward)) signal | Slide switch off | 11 to 14 V |
| Slide switch on (Forward) | Below 1 V | ||
| i19-23 (SLDR) - Body ground | Front power seat switch LH (slide switch (rearward)) signal | Slide switch off | 11 to 14 V |
| Slide switch on (Rearward) | Below 1 V | ||
| i19-8 (RCLF) - Body ground | Front power seat switch LH (reclining switch (forward)) signal | Reclining switch off | 11 to 14 V |
| Reclining switch on (Forward) | Below 1 V | ||
| i19-22 (RCLR) - Body ground | Front power seat switch LH (reclining switch (rearward)) signal | Reclining switch off | 11 to 14 V |
| Reclining switch on (Rearward) | Below 1 V | ||
| i19-6 (FRVU) - Body ground | Front power seat switch LH (front vertical switch (upward)) signal | Front vertical switch off | 11 to 14 V |
| Front vertical switch on (Upward) | Below 1 V | ||
| i19-20 (FRVD) - Body ground | Front power seat switch LH (front vertical switch (downward)) signal | Front vertical switch off | 11 to 14 V |
| Front vertical switch on (Downward) | Below 1 V | ||
| i19-7 (LFTU) - Body ground | Front power seat switch LH (lifter switch (upward)) signal | Lifter switch off | 11 to 14 V |
| Lifter switch on (Upward) | Below 1 V | ||
| i19-21 (LFTD) - Body ground | Front power seat switch LH (lifter switch (downward)) signal | Lifter switch off | 11 to 14 V |
| Lifter switch on (Downward) | Below 1 V | ||
| i19-12 (SGND) - Body ground | Sensor ground | Always | Below 1 Ω |
Check for pulses according to the value (s) in the table below.
| Tester Connection | Terminal Description | Condition | Specified Condition |
|---|---|---|---|
| i19-10 (SSFV) - Body ground | Front vertical position signal | Front vertical function operating | Pulse generation |
| i19-11 (SSRR) - Body ground | Reclining position signal | Reclining function operating | Pulse generation |
| i19-25 (SSRL) - Body ground | Lifter position signal | Lifter function operating | Pulse generation |
| i19-26 (SSRS) - Body ground | Slide position signal | Slide function operating | Pulse generation |
CHECK POSITION CONTROL ECU ASSEMBLY (for RHD)
Disconnect the h22 and h24 position control ECU assembly connectors.
Measure the voltage and resistance according to the value(s) in the table below.
Measure the values on the wire harness side with the connector disconnected.
| Tester Connection | Terminal Description | Condition | Specified Condition |
|---|---|---|---|
| h22-3 (+B) - Body ground | Battery power supply | Always | 11 to 14 V |
| h24-1 (IG) - Body ground | Ignition power supply | Ignition switch off | Below 1 V |
| Ignition switch ON | 11 to 14 V | ||
| h24-15 (SYSB) - Body ground | System power source | Always | 11 to 14 V |
| h22-2 (GND) - Body ground | Ground | Always | Below 1 Ω |
| h24-27 (DBCL) - Body ground | Driver seat belt buckle switch signal | Driver seat belt unfastened | 10 kΩ or higher |
| Driver seat belt fastened | Below 1 Ω |
Reconnect the h22 and h24 position control ECU assembly connectors.
Measure the voltage and resistance according to the value (s) in the table below.
| Tester Connection | Terminal Description | Condition | Specified Condition |
|---|---|---|---|
| h22-1 (SLD+) - Body ground | Slide motor signal (forward) | Slide switch off | Below 1 V |
| Slide switch on (Forward) | 11 to 14 V | ||
| h22-5 (SLD-) - Body ground | Slide motor signal (rearward) | Slide switch off | Below 1 V |
| Slide switch on (Rearward) | 11 to 14 V | ||
| h22-6 (LFT+) - Body ground | Lifter motor signal (upward) | Lifter switch off | Below 1 V |
| Lifter switch on (Upward) | 11 to 14 V | ||
| h23-5 (LFT-) - Body ground | Lifter motor signal (downward) | Lifter switch off | Below 1 V |
| Lifter switch on (Downward) | 11 to 14 V | ||
| h22-10 (RCL+) - Body ground | Reclining motor signal (forward) | Reclining switch off | Below 1 V |
| Reclining switch on (Forward) | 11 to 14 V | ||
| h23-6 (RCL-) - Body ground | Reclining motor signal (rearward) | Reclining switch off | Below 1 V |
| Reclining switch on (Rearward) | 11 to 14 V | ||
| h22-7 (FRV+) - Body ground | Front vertical motor signal (upward) | Front vertical switch off | Below 1 V |
| Front vertical switch on (Upward) | 11 to 14 V | ||
| h23-4 (FRV-) - Body ground | Front vertical motor signal (downward) | Front vertical switch off | Below 1 V |
| Front vertical switch on (Downward) | 11 to 14 V | ||
| h22-9 (L+) - Body ground | Lumbar support adjuster motor signal (forward) | Lumbar support adjuster switch off | Below 1 V |
| Lumbar support adjuster switch on (Forward) | 11 to 14 V | ||
| h23-3 (L-) - Body ground | Lumbar support adjuster motor signal (rearward) | Lumbar support adjuster switch off | Below 1 V |
| Lumbar support adjuster switch on (Rearward) | 11 to 14 V | ||
| h24-4 (LFLF) - Body ground | Front power seat switch RH (lumbar support adjuster switch (forward)) signal | Lumbar support adjuster switch off | 11 to 14 V |
| Lumbar support adjuster switch on (Forward) | Below 1 V | ||
| h24-18 (LFLR) - Body ground | Front power seat switch RH (lumbar support adjuster switch (rearward)) signal | Lumbar support adjuster switch off | 11 to 14 V |
| Lumbar support adjuster switch on (Rearward) | Below 1 V | ||
| h24-9 (SLDF) - Body ground | Front power seat switch RH (slide switch (forward)) signal | Slide switch off | 11 to 14 V |
| Slide switch on (Forward) | Below 1 V | ||
| h24-23 (SLDR) - Body ground | Front power seat switch RH (slide switch (rearward)) signal | Slide switch off | 11 to 14 V |
| Slide switch on (Rearward) | Below 1 V | ||
| h24-8 (RCLF) - Body ground | Front power seat switch RH (reclining switch (forward)) signal | Reclining switch off | 11 to 14 V |
| Reclining switch on (Forward) | Below 1 V | ||
| h24-22 (RCLR) - Body ground | Front power seat switch RH (reclining switch (rearward)) signal | Reclining switch off | 11 to 14 V |
| Reclining switch on (Rearward) | Below 1 V | ||
| h24-6 (FRVU) - Body ground | Front power seat switch RH (front vertical switch (upward)) signal | Front vertical switch off | 11 to 14 V |
| Front vertical switch on (Upward) | Below 1 V | ||
| h24-20 (FRVD) - Body ground | Front power seat switch RH (front vertical switch (downward)) signal | Front vertical switch off | 11 to 14 V |
| Front vertical switch on (Downward) | Below 1 V | ||
| h24-7 (LFTU) - Body ground | Front power seat switch RH (lifter switch (upward)) signal | Lifter switch off | 11 to 14 V |
| Lifter switch on (Upward) | Below 1 V | ||
| h24-21 (LFTD) - Body ground | Front power seat switch RH (lifter switch (downward)) signal | Lifter switch off | 11 to 14 V |
| Lifter switch on (Downward) | Below 1 V | ||
| h24-12 (SGND) - Body ground | Sensor ground | Always | Below 1 Ω |
Check for pulses according to the value (s) in the table below.
| Tester Connection | Terminal Description | Condition | Specified Condition |
|---|---|---|---|
| h24-10 (SSFV) - Body ground | Front vertical position signal | Front vertical function operating | Pulse generation |
| h24-11 (SSRR) - Body ground | Reclining position signal | Reclining function operating | Pulse generation |
| h24-25 (SSRL) - Body ground | Lifter position signal | Lifter function operating | Pulse generation |
| h24-26 (SSRS) - Body ground | Slide position signal | Slide function operating | Pulse generation |
CHECK MAIN BODY ECU (MULTIPLEX NETWORK BODY ECU) AND POWER DISTRIBUTION BOX ASSEMBLY
| *1 | Power Distribution Box Assembly | *2 | Main Body ECU (Multiplex Network Body ECU) |
Remove the main body ECU (multiplex network body ECU) from the power distribution box assembly.
for LHD: Click herePower Source / Network>POWER DISTRIBUTION>MAIN BODY ECU (for LHD)>REMOVAL
for RHD: Click herePower Source / Network>POWER DISTRIBUTION>MAIN BODY ECU (for RHD)>REMOVAL
Reconnect the power distribution box assembly connectors.
Measure the voltage and resistance according to the value (s) in the table below.
| Tester Connection | Terminal Description | Condition | Specified Condition |
|---|---|---|---|
| MB-26 (BECU) - Body ground | Battery power supply | Always | 11 to 14 V |
| MB-27 (IGR) - Body ground | Ignition power supply | Ignition switch ON | 11 to 14 V |
| MB-27 (IGR) - Body ground | Ignition power supply | Ignition switch off | Below 1 V |
| MB-13 (GND1) - Body ground | Ground | Always | Below 1 Ω |
Install the main body ECU (multiplex network body ECU) to power distribution box assembly.
for LHD: Click herePower Source / Network>POWER DISTRIBUTION>MAIN BODY ECU (for RHD)>INSTALLATION
for RHD: Click herePower Source / Network>POWER DISTRIBUTION>MAIN BODY ECU (for LHD)>INSTALLATION
Measure the voltage for pulses according to the value(s) in the table below.
| Tester Connection | Terminal Description | Condition | Specified Condition |
|---|---|---|---|
|
*1: for RHD *2: for LHD |
|||
| MB-4 (FRCY) - Body ground*1 | Front door courtesy light switch assembly (for RH) signal | Front door RH open | Below 1 V |
| Front door RH closed | 4.7 to 5.3 V | ||
| MB-2 (FLCY) - Body ground*2 | Front door courtesy light switch assembly (for LH) signal | Front door LH open | Below 1 V |
| Front door LH closed | 4.7 to 5.3 V | ||