| *A | for Standard | *B | for Type A |
| *C | for Type B | - | - |
| ● | Non-reusable part | - | - |
| *A | w/ Roof Rack | *B | for Type A |
| *C | for Type B | - | - |
| ● | Non-reusable part | - | - |
| *A | w/ Roof Carrier | *B | for Type A |
| *C | for Type B | - | - |
| ● | Non-reusable part | - | - |
| Procedure | Part Name Code |
|
|
|
|
|---|---|---|---|---|---|
| 1 | ROOF DRIP SIDE FINISH MOULDING CLIP | 75561A | ( ) |
- | - |
| 2 | REAR ROOF DRIP SIDE FINISH MOULDING LH | 75554A | ( ) |
- | - |
| 3 | ROOF DRIP SIDE FINISH MOULDING LH | 75552 | - | - | - |
| *A | w/ Roof Rack Assembly LH | - | - |
| ● | Non-reusable part | - | - |
| Procedure | Part Name Code |
|
|
|
|
|---|---|---|---|---|---|
| 8 | ROOF RACK ASSEMBLY LH | 63470B | - | - | - |
| 9 | ROOF CARRIER SUB-ASSEMBLY LH | 63408C | - | - | - |
| 10 | ROOF RACK ASSEMBLY | - | - | - | - |
| *A | w/ Roof Rack Assembly LH | *B | w/ Roof Carrier |
| *C | w/ Roof Rack | - | - |
Use the same procedure for the RH and LH sides.
The procedure described below is for the LH side.
75561A 1.INSTALL ROOF DRIP SIDE FINISH MOULDING CLIP
|
|
| *a | Adhesive | *b | 2 to 3 mm (0.0787 to 0.1181 in.) Bead of Adhesive |
| Area | Measurement | Area | Measurement |
|---|---|---|---|
| A | 0 to 2.0 mm (0 to 0.0787 in.) | B | 6.2 to 7.2 mm (0.244 to 0.283 in.) |
Apply a 2 to 3 mm (0.0787 to 0.118 in.) bead of adhesive (3M DP-105 or equivalent) to each new roof drip side finish moulding clip.
Adhesive strength (tensile strength): 13.7 MPa (140.0 kgf/cm2, 1987 psi) or more (when the temperature is 23°C (73°F).)
Apply primer to the body where the roof drip side finish moulding clip will be installed.
Do not let the primer dry.
While using the position shown in the illustration as a reference, place the roof drip side finish moulding clip onto the roof panel. Then position and install the clip using the locations on the roof panel after lightly pressing it so that the adhesive adheres to the primer.
Install the center roof drip side finish moulding LH when 40 minutes or more have elapsed after pressing and installing the roof drip side finish moulding clips.
Initial hardening time: 40 minutes
Complete hardening time: 24 hours
75554A 2.INSTALL REAR ROOF DRIP SIDE FINISH MOULDING LH
|
|
| Part | Temperature |
|---|---|
| Vehicle Body | 40 to 60°C (104 to 140°F) |
| Rear Roof Drip Side Finish Moulding LH | 20 to 30°C (68 to 86°F) |
| *a | Heated Part |
| *b | Heat Light |
Do not touch the heat light and heated parts.
Touching the heat light may result in burns.
Touching heated parts for a long time may result in burns.
Do not heat the rear roof drip side finish moulding LH and vehicle body excessively.
for Type A:
| *a | Triangle Protrusion | *b | Double-sided Tape |
Clean the vehicle body surface.
1. When reusing the vehicle body, remove remaining double-sided tape from the vehicle body.
2. Using a heat light, heat the vehicle body surface.
3. Remove any remaining double-sided tape from the vehicle body and wipe off any tape adhesive residue with cleaner.
4. Clean the installation area surface.
Installing the rear roof drip side finish moulding LH with some double-sided tape remaining may cause poor adhesion. Perform this procedure until the tape is sufficiently removed.
Make sure to use a cloth when removing. Using a screwdriver, etc., may cause damage and poor adhesion.
Using a heat light, heat the vehicle body and a new rear roof drip side finish moulding LH.
Attach the clip and claw and double-sided tape to install the rear roof drip side finish moulding LH in the position shown in the illustration.
The application strength of the rear roof drip side finish moulding LH will weaken if reapplied. If reapplication is necessary, be sure to replace it with a new one.
Apply pressure so that it does not lift up from the vehicle body.
for Type B:
| *a | Triangle Protrusion | - | - |
Attach the clip and claw to install the rear roof drip side finish moulding LH in the position shown in the illustration.
75552 3.INSTALL ROOF DRIP SIDE FINISH MOULDING LH
| *a | Triangle Protrusion | - | - |
|
Install in this Direction (1) |
|
Install in this Direction (2) |
75556 4.INSTALL REAR ROOF DRIP SIDE FINISH MOULDING LH (for Standard or w/Roof Rack or w/ Roof Carrier)
| *a | Triangle Protrusion | - | - |
75556C 5.INSTALL CENTER ROOF DRIP SIDE FINISH MOULDING LH (for Standard or w/Roof Rack or w/ Roof Carrier)
| *a | Triangle Protrusion | - | - |
75552H 6.INSTALL ROOF DRIP SIDE MOULDING LH (for Standard or w/ Roof Rack)
| *a | Triangle Protrusion | - | - |
75597 7.INSTALL ROOF DRIP SIDE FINISH MOULDING JOINT COVER LH (for Standard or w/Roof Rack or w/ Roof Carrier)
63470B 8.INSTALL ROOF RACK ASSEMBLY LH (w/ Roof Rack Assembly LH)
63408C 9.INSTALL ROOF CARRIER SUB-ASSEMBLY LH (w/ Roof Carrier)
10.INSTALL ROOF RACK ASSEMBLY (w/ Roof Rack)