Home › Power Source / Network › 1GR-FE (BATTERY / CHARGING) › CHARGING SYSTEM
RM38G0E _57 Power Source / Network _101114 1GR-FE BATTERY / CHARGING _0469187 CHARGING SYSTEM C

1GR-FE BATTERY / CHARGING  CHARGING SYSTEM  P062049  Generator Control Circuit Internal Electronic Failure  


DESCRIPTION

The alternator performs self-diagnosis of its internal circuits to detect malfunctions (open or short circuits).

The ECM receives the result via LIN communication and stores a DTC.

DTC No. Detection Item DTC Detection Condition Trouble Area Warning Indicate Note
P062049 Generator Control Circuit Internal Electronic Failure Open or short in F circuit, or abnormal waveform for P circuit.
(1 trip detection logic)
Generator assembly Charge warning is displayed SAE: P0620

HINT:

A charge warning is displayed only when the malfunction continues.


CAUTION / NOTICE / HINT

NOTICE:

Inspect the fuses for circuits related to this system before performing the following inspection procedure.


PROCEDURE

1.CHARGING CIRCUIT WITHOUT LOAD

OK

2.CHARGING CIRCUIT WITH LOAD

NG

REPAIR OR REPLACE GENERATOR ASSEMBLY