The No. 1 skid control ECU (brake booster with master cylinder assembly) detects decreases in the accumulator pressure according to the data from the accumulator pressure sensor, and then starts and stops the pump motor by operating the motor relay.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | DTC Output from | Note |
|---|---|---|---|---|---|
| C141C12 | Brake Booster Motor "A" Control Circuit Short to Battery | A short is detected in the motor relay drive circuit for 2 seconds or more. |
·
Short in pump motor circuit or pump motor monitor circuit
·
No. 1 skid control ECU (brake booster with master cylinder assembly) |
Brake Booster | Output ECU: No. 1 skid control ECU (brake booster with master cylinder assembly) |
| C141C14 | Brake Booster Motor "A" Control Circuit Short to Ground or Open | When the +BI1 voltage is between 7.3 and 16.6 V and the duty ratio of the pump motor is at 100%, the difference between the voltage at terminal MRI1 and the voltage at the pump motor is more than 1.5 V for 0.12 seconds or more. |
·
Wire harness and connector
·
No. 1 skid control ECU (brake booster with master cylinder assembly) |
Brake Booster | Output ECU: No. 1 skid control ECU (brake booster with master cylinder assembly) |
| C141C1C | Brake Booster Motor "A" Control Circuit Voltage Out of Range | An open is detected in the motor relay drive circuit for 2 seconds or more. |
·
Open in pump motor circuit or pump motor monitor circuit
·
No. 1 skid control ECU (brake booster with master cylinder assembly) |
Brake Booster | Output ECU: No. 1 skid control ECU (brake booster with master cylinder assembly) |
Refer to DTC C059400.
Click hereBrake>BRAKE CONTROL / DYNAMIC CONTROL SYSTEMS>ELECTRONICALLY CONTROLLED BRAKE SYSTEM>C059400
Inspect the fuses for circuits related to this system before performing the following procedure.
After replacing the No. 1 skid control ECU (brake booster with master cylinder assembly), perform "Calibration".
Click hereBrake>BRAKE CONTROL / DYNAMIC CONTROL SYSTEMS>ELECTRONICALLY CONTROLLED BRAKE SYSTEM>UTILITY
Check the DTCs that are output.
| Result | Proceed to |
|---|---|
| C141C12, C141C14 or C141C1C is output | A |
| C141C12, C141C14 or C141C1C and other DTCs are output | B |
A
B
Depress the brake pedal several times and check the operation status of the motor relay.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| ECB Motor Relay | Motor relay operation request | OFF / ON | OFF: Relay off ON: Relay on |
ECB: Electronically Controlled Brake System |
| Tester Display |
|---|
| ECB Motor Relay |
Depressing the brake pedal several times drops the accumulator pressure and operates the pump motor.
| Result | Proceed to |
|---|---|
| The status of motor relay in the Data List turns on and off after depressing the brake pedal several times. | A |
| The status of motor relay in the Data List does not change even after depressing the brake pedal several times. | B |
A
B
OK
NG
Make sure that there is no looseness at the locking part and the connecting part of the connector.
The connector is securely connected.
Disconnect the B19 No. 1 skid control ECU (brake booster with master cylinder assembly) connector.
Check both the connector case and the terminals for deformation and corrosion.
No deformation or corrosion.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
Click Location & Routing(B18,B19)Location & Routingewd_type=routing;type=c,c;code=B18,B19 |
||
| B18-2 (GND1) - B19-30 (M-) | Always | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Reconnect the B18 brake booster with accumulator pump assembly connector.
Reconnect the B19 No. 1 skid control ECU (brake booster with master cylinder assembly) connector.
Disconnect the B15 brake pedal stroke sensor assembly connector.
Depress the brake pedal several times to operate the pump motor, then wait until it stops.
After the pump motor stops, wait for 30 seconds, then check the drop in the accumulator pressure sensor output value and the state of the pump motor.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| ECB Motor Relay | Motor relay operation request | OFF / ON | OFF: Relay off ON: Relay on |
ECB: Electronically Controlled Brake System |
| Accumulator Pressure | Accumulator pressure output value | Min.: 0.00 MPa Max.: 24.48 MPa |
15.00 to 21.00 MPa (Pressure stable and pump motor stopped) | When brake fluid is stored in the accumulator: Accumulator pressure changes in accordance with volume of fluid stored in the accumulator |
| Tester Display |
|---|
| ECB Motor Relay |
| Accumulator Pressure |
This inspection checks whether an accumulator pressure sensor malfunction, internal brake booster with master cylinder assembly leak or prolonged operation due to detection of low pressure caused by accumulator deterioration, caused the DTC to be stored.
If the brake fluid level in the brake fluid level warning switch (brake booster with master cylinder assembly) drops, an external brake fluid leak is suspected.
| Result | Proceed to |
|---|---|
| The drop in the accumulator pressure sensor output value is less than 2.50 MPa 30 seconds after the pump motor stops, and the pump motor does not operate within 30 seconds after the pump motor stops. | A |
| The drop in the accumulator pressure sensor output value is 2.50 MPa or more 30 seconds after the pump motor stops, or the pump motor operates within 30 seconds after the pump motor stops. | B |
A
B
Turn the ignition switch off.
Reconnect the B15 brake pedal stroke sensor assembly connector.
Clear the DTCs.
Turn the ignition switch off.
| Proceed to |
|---|
| NEXT |
NEXT
Based on the Freeze Frame Data and interview with the customer, attempt to reproduce the conditions when the malfunction occurred.
Check if the same DTC is output.
| Result | Proceed to |
|---|---|
| C141C12, C141C14 and C141C1C are not output | A |
| C141C12, C141C14 or C141C1C is output | B |
A
Click hereGeneral>INTRODUCTION>HOW TO TROUBLESHOOT ECU CONTROLLED SYSTEMS>HOW TO PROCEED WITH TROUBLESHOOTING
B
for LHD: Click hereBrake>BRAKE SYSTEM (OTHER)>BRAKE BOOSTER (for LHD)>REMOVAL
for RHD: Click hereBrake>BRAKE SYSTEM (OTHER)>BRAKE BOOSTER (for RHD)>REMOVAL
Turn the ignition switch off.
Reconnect the B15 brake pedal stroke sensor assembly connector.
Drive the linear solenoid (SLA) by performing the Active Test to reduce the accumulator pressure.
Perform the Active Test with the current set to maximum.
After reducing the accumulator pressure, confirm that the pump motor starts and the accumulator pressure returns to 15.00 to 21.00 MPa.
| Tester Display | Measurement Item | Control Range | Restrict Condition | Diagnostic Note |
|---|---|---|---|---|
| ECB Solenoid (SLA) | Linear solenoid addition valve (SLA) | Solenoid Start (Activate) Solenoid SLA (It is possible to set the current) |
Vehicle condition:
·
Vehicle stopped
·
Shift lever is in P
·
Apply the parking brake |
ECB: Electronically Controlled Brake System |
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Accumulator Pressure | Accumulator pressure output value | Min.: 0.00 MPa Max.: 24.48 MPa |
15.00 to 21.00 MPa (Pressure stable and pump motor stopped) | When brake fluid is stored in the accumulator: Accumulator pressure changes in accordance with volume of fluid stored in the accumulator |
| Active Test Display |
|---|
| ECB Solenoid (SLA) |
| Data List Display |
|---|
| Accumulator Pressure |
The accumulator pressure reduces, and then returns to 15.00 to 21.00 MPa when the pump motor operates.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
for LHD: Click hereBrake>BRAKE SYSTEM (OTHER)>BRAKE BOOSTER (for LHD)>REMOVAL
for RHD: Click hereBrake>BRAKE SYSTEM (OTHER)>BRAKE BOOSTER (for RHD)>REMOVAL
Confirm that the pump motor inside the brake booster with accumulator pump assembly is stopped.
Based on the Freeze Frame Data and interview with the customer, attempt to reproduce the conditions when the malfunction occurred.
Check if the same DTC is output.
| Result | Proceed to |
|---|---|
| C141C12, C141C14 and C141C1C are not output | A |
| C141C12, C141C14 or C141C1C is output | B |
A
Click hereGeneral>INTRODUCTION>HOW TO TROUBLESHOOT ECU CONTROLLED SYSTEMS>HOW TO PROCEED WITH TROUBLESHOOTING
B
for LHD: Click hereBrake>BRAKE SYSTEM (OTHER)>BRAKE BOOSTER (for LHD)>REMOVAL
for RHD: Click hereBrake>BRAKE SYSTEM (OTHER)>BRAKE BOOSTER (for RHD)>REMOVAL
Turn the ignition switch off.
Make sure that there is no looseness at the locking part and the connecting part of the connector.
The connector is securely connected.
Disconnect the B19 No. 1 skid control ECU (brake booster with master cylinder assembly) connector.
Check both the connector case and the terminals for deformation and corrosion.
No deformation or corrosion.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
Click Location & Routing(B19)Location & Routingewd_type=routing;type=c;code=B19 |
||
| B19-1 (MRI1) - Body ground | Always | 11 to 14 V |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Make sure that there is no looseness at the locking part and the connecting part of the connector.
The connector is securely connected.
Disconnect the B18 brake booster with accumulator pump assembly connector.
Check both the connector case and the terminals for deformation and corrosion.
No deformation or corrosion.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
Click Location & Routing(B19,B18)Location & Routingewd_type=routing;type=c,c;code=B19,B18 |
||
| B19-29 (M+) - B18-1 (BM1) | Always | Below 1 Ω |
| B19-29 (M+) or B18-1 (BM1) - Body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
for LHD: Click hereBrake>BRAKE SYSTEM (OTHER)>BRAKE BOOSTER (for LHD)>REMOVAL
for RHD: Click hereBrake>BRAKE SYSTEM (OTHER)>BRAKE BOOSTER (for RHD)>REMOVAL
NG