Home › Suspension › SUSPENSION CONTROL › ELECTRONIC-KINETIC DYNAMIC SUSPENSION SYSTEM
RM38G0E _53 Suspension _100546 SUSPENSION CONTROL _0470891 ELECTRONIC-KINETIC DYNAMIC SUSPENSION SYSTEM C

SUSPENSION CONTROL  ELECTRONIC-KINETIC DYNAMIC SUSPENSION SYSTEM  C183914  Rr Stabilizer Solenoid A Control Circuit Circuit Short to Ground or Open  


DESCRIPTION

DTC No. Detection Item DTC Detection Condition Trouble Area DTC Output from
C183914 Rr Stabilizer Solenoid A Control Circuit Circuit Short to Ground or Open Open circuit detected in solenoid valve
·

Stabilizer control with accumulator housing assembly

·

Harness or connector

·

Stabilizer control ECU


Electronic-Kinetic Dynamic Suspension System (E-KDSS)

PROCEDURE

1.CHECK HARNESS AND CONNECTOR (STABILIZER CONTROL ECU - STABILIZER CONTROL WITH ACCUMULATOR HOUSING ASSEMBLY)
a.

Disconnect the Q13 stabilizer control ECU connector.


b.

Disconnect the vV1 stabilizer control with accumulator housing assembly connector.


c.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition

Click Location & Routing(Q13,vV1)Location & Routing

Click Connector(Q13)Body>Air Conditioning Wiring Harness Assembly / Floor Wire / Step Rear Floor Wire RH / Theft Warning Sensor Cord Sub-Assembly>Stabilizer Control ECU

Click Connector(vV1)Body>Stabilizer Control Wire>Stabilizer Control Wire and Frame Wire

Q13-6 (RUP+) - vV1-1 Always Below 1 Ω
Q13-5 (RUP-) - vV1-2 Always Below 1 Ω
Q13-6 (RUP+) or vV1-1 - Body ground Always 10 kΩ or higher
Q13-5 (RUP-) or vV1-2 - Body ground Always 10 kΩ or higher



d.

Connect the vV1 stabilizer control with accumulator housing assembly connector.


e.

Connect the Q13 stabilizer control ECU connector.


Result:
Proceed to
OK
NG



OK

2.INSPECT STABILIZER CONTROL WITH ACCUMULATOR HOUSING ASSEMBLY (REAR UPPER CHAMBER SOLENOID VALVE)

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

2.INSPECT STABILIZER CONTROL WITH ACCUMULATOR HOUSING ASSEMBLY (REAR UPPER CHAMBER SOLENOID VALVE)
a.
C457010C03
0.104,0.083 0.417,0.24 0.313,0.156 10 false *a
*a Component without harness connected
(Stabilizer Control with Accumulator Housing Assembly)


Disconnect the vV1 stabilizer control with accumulator housing assembly connector.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1 - 2 25°C (77°F) 4.58 to 5.02 Ω



c.

Connect the vV1 stabilizer control with accumulator housing assembly connector.


Result:
Proceed to
OK
NG



OK

REPLACE STABILIZER CONTROL ECU

NG

REPLACE STABILIZER CONTROL WITH ACCUMULATOR HOUSING ASSEMBLY