| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | DTC Output from |
|---|---|---|---|---|
| C183914 | Rr Stabilizer Solenoid A Control Circuit Circuit Short to Ground or Open | Open circuit detected in solenoid valve |
·
Stabilizer control with accumulator housing assembly
·
Harness or connector
·
Stabilizer control ECU |
Electronic-Kinetic Dynamic Suspension System (E-KDSS) |
Refer to C183912.
Click hereSuspension>SUSPENSION CONTROL>ELECTRONIC-KINETIC DYNAMIC SUSPENSION SYSTEM>C183912
Disconnect the Q13 stabilizer control ECU connector.
Disconnect the vV1 stabilizer control with accumulator housing assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
Click Location & Routing(Q13,vV1)Location & Routingewd_type=routing;type=c,w;code=Q13,vV1 Click Connector(vV1)Body>Stabilizer Control Wire>Stabilizer Control Wire and Frame Wireewd_type=component;type=w;code=vV1;pinno=1,2 |
||
| Q13-6 (RUP+) - vV1-1 | Always | Below 1 Ω |
| Q13-5 (RUP-) - vV1-2 | Always | Below 1 Ω |
| Q13-6 (RUP+) or vV1-1 - Body ground | Always | 10 kΩ or higher |
| Q13-5 (RUP-) or vV1-2 - Body ground | Always | 10 kΩ or higher |
Connect the vV1 stabilizer control with accumulator housing assembly connector.
Connect the Q13 stabilizer control ECU connector.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| *a | Component without harness connected (Stabilizer Control with Accumulator Housing Assembly) |
Disconnect the vV1 stabilizer control with accumulator housing assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1 - 2 | 25°C (77°F) | 4.58 to 5.02 Ω |
Connect the vV1 stabilizer control with accumulator housing assembly connector.
| Proceed to |
|---|
| OK |
| NG |
OK
NG